In vitro and in vivo biocompatibility evaluation of a novobiocin stimulus-responsive poly(ethylene glycol)-based hydrogel designed for soft tissue regeneration

被引:4
|
作者
Laird, Dougal [1 ]
El-Baba, Marie Daoud [2 ]
Charpin-El Hamri, Ghislaine [2 ]
Eberwein, Philipp [3 ]
Nelson, Katja [4 ]
Tomakidi, Pascal [1 ]
Steinberg, Thorsten [1 ]
机构
[1] Univ Med Ctr Freiburg, Dept Oral Biotechnol, D-79106 Freiburg, Germany
[2] Univ Lyon, Dept Genie Biol, IUT, Lyon, France
[3] Univ Eye Hosp Freiburg, Dept Ophthalmol, Freiburg, Germany
[4] Univ Med Ctr Freiburg, Dept Craniomaxillofacial Surg, Freiburg, Germany
关键词
Poly(ethylene glycol) (PEG)-based hydrogel; stimulus responsive; impedance measurement; cytotoxicity; novobiocin; coumermycin; biocompatibility; PROTEIN; RGD; BIOMATERIALS; COMBINATION; EXPRESSION; SURFACES; CELLS;
D O I
10.1177/0883911515570370
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
In vitro and in vivo biocompatibility evaluation of medical devices designed for soft tissue healing and regeneration is mandatory for new biomaterials targeted toward human application. To this end, a novel stimulus-responsive eight-arm poly(ethylene glycol) (PEG)-based hydrogel for soft tissue regeneration was subjected to preclinical safety evaluation. While in vitro safety testing included determination of half-maximal inhibitory concentrations by cell index impedance measurements, an in vivo pilot rat study focused on detectable signs of oral mucosal inflammation. In a hydrogel with a total volume of 40 mu L, the following concentrations of the constituents were released upon hydrogel dissolution in 1mL body fluid: PEG, 19 mu M; gyrase B, 152 mu M; and coumermycin, 76 mu M, while the dissolving agent novobiocin was effective in a range from 50 to 100 mu M. Concerning the components' biological effects, half-maximal inhibitory concentrations of 806 and 95 mu M for human oral mucosal gingival fibroblasts and gingival keratinocytes were calculated for novobiocin, proving gingival keratinocytes more susceptible to substance effects. Furthermore, with respect to coumermycin concentrations, half-maximal inhibitory concentrations of 10 and 3 mu M for gingival fibroblasts and gingival keratinocytes, respectively, were obtained, and thereby revealed coumermycin to be toxic in vitro. In vivo, submucosal hard palatal implantation of standard hydrogels showed no evidence of inflammation at any time point under study, which was supported by immunohistochemistry analysis. In order to realize the potential of such a promising stimulus-responsive hydrogel biomaterial concept for soft tissue wound healing and/or regenerative applications, the crosslinker coumermycin and its competitor novobiocin should be replaced by more innocuous alternative protein-ligand pairs.
引用
收藏
页码:319 / 339
页数:21
相关论文
共 50 条
  • [1] In vitro and in vivo biocompatibility evaluation of a polyalkylimide hydrogel for soft tissue augmentation
    Ramires, PA
    Miccoli, MA
    Panzarini, E
    Dini, L
    Protopapa, C
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 72B (02) : 230 - 238
  • [2] The adsorption behaviors of the multiple stimulus-responsive poly(ethylene glycol)-based hydrogels for removal of RhB dye
    Yuan, Zhicheng
    Wang, Yang
    Han, Xiao
    Chen, Dajun
    JOURNAL OF APPLIED POLYMER SCIENCE, 2015, 132 (28)
  • [4] Influence of End Groups on the Stimulus-Responsive Behavior of Poly[oligo(ethylene glycol) methacrylate] in Water
    Roth, Peter J.
    Jochum, Florian D.
    Forst, F. Romina
    Zentel, Rudolf
    Theato, Patrick
    MACROMOLECULES, 2010, 43 (10) : 4638 - 4645
  • [5] Biocompatibility and Drug Release of Poly(Ethylene) Glycol (PEG)-Based Hydrogel in Healthy Rat Brain Tissue
    Bjugstad, K. B.
    Lampe, K.
    Kern, D. S.
    Mahoney, M.
    CELL TRANSPLANTATION, 2009, 18 (02) : 210 - 210
  • [6] In Vitro and In Vivo Evaluation of 3D Printed Poly(Ethylene Glycol) Dimethacrylate-Based Photocurable Hydrogel Platform for Bone Tissue Engineering
    Unagolla, Janitha M.
    Gaihre, Bipin
    Jayasuriya, Ambalangodage C.
    MACROMOLECULAR BIOSCIENCE, 2024, 24 (04)
  • [7] Stimulus-Responsive, Biodegradable, Biocompatible, Covalently Cross-Linked Hydrogel Based on Dextrin and Poly(N-isopropylacrylamide) for in Vitro/in Vivo Controlled Drug Release
    Das, Dipankar
    Ghosh, Paulomi
    Ghosh, Animesh
    Haldar, Chanchal
    Dhara, Santanu
    Panda, Asit Baran
    Pal, Sagar
    ACS APPLIED MATERIALS & INTERFACES, 2015, 7 (26) : 14338 - 14351
  • [8] In vitro cytotoxicity and in vivo biocompatibility of poly(propylene fumarate-co-ethylene glycol) hydrogels
    Suggs, LJ
    Shive, MS
    Garcia, CA
    Anderson, JM
    Mikos, AG
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1999, 46 (01): : 22 - 32
  • [9] Synthesis, preparation, and conformation of stimulus-responsive end-grafted layers of poly(methacrylic acid-g-ethylene glycol)
    Ye, M
    Zhang, D
    Han, L
    Ortiz, C
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U4135 - U4135
  • [10] Synthesis, preparation, and conformation of stimulus-responsive end-grafted poly(methacrylic acid-g-ethylene glycol) layers
    Ye, M
    Zhang, D
    Han, L
    Tejada, J
    Ortiz, C
    SOFT MATTER, 2006, 2 (03) : 243 - 256