Scapular Motion Tracking Using Acromion Skin Marker Cluster: In Vitro Accuracy Assessment

被引:13
|
作者
Cereatti, Andrea [1 ,2 ]
Rosso, Claudio [3 ,4 ,5 ]
Nazarian, Ara [4 ,5 ]
DeAngelis, Joseph P. [5 ,6 ]
Ramappa, Arun J. [5 ,6 ]
Della Croce, Ugo [1 ]
机构
[1] Univ Sassari, POLCOMING Dept, Informat Engn Unit, I-07100 Sassari, Italy
[2] Univ Sassari, Dept Informat Engn Polit Sci & Commun Sci, I-07100 Sassari, Italy
[3] Univ Basel, Univ Basel Hosp, Dept Orthopaed, Basel, Switzerland
[4] Beth Israel Deaconess Med Ctr, Ctr Adv Orthopaed Studies, Boston, MA 02215 USA
[5] Harvard Univ, Sch Med, Boston, MA USA
[6] Beth Israel Deaconess Med Ctr, Dept Orthopaed Surg, Boston, MA 02215 USA
基金
瑞士国家科学基金会;
关键词
Acromion marker cluster; Scapular motion; Pitching; Throwing; Soft tissue artifacts; ANATOMICAL LANDMARK CALIBRATION; SCAPULOHUMERAL RHYTHM; SHOULDER; KINEMATICS; ARM; BIOMECHANICS; ORIENTATION; ELEVATION; MOVEMENT; ROTATION;
D O I
10.1007/s40846-015-0010-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Several studies have recently investigated how the implementations of acromion marker clusters (AMCs) method and stereo-photogrammetry affect the estimates of scapula kinematics. However, in the large majority of these studies, the accuracy assessment of the scapular kinematics obtained with AMCs was carried out through a comparative evaluation using a scapula locator that is prone to error. The present study assesses AMC accuracy based on best practice recommendations, both with single and double anatomical calibration implementations, during several passive shoulder movements. Experiments were carried out on three cadaveric specimens. The scapula motion was acquired with a stereo-photogrammetric system using intra-cortical pins. When the scapula kinematics was estimated using an AMC combined with a single anatomical calibration, the accuracy was highly dependent on the specimen and the type of motion (maximum errors between -6.2 degrees and 44.8 degrees) and the scapular motion was generally overestimated. Moreover, with this implementation, scapular orientation errors increased for shoulder configurations distant from the reference shoulder configuration chosen for the calibration procedure. The double calibration implementation greatly improved the estimate of the scapular kinematics for all specimens and types of motion ( maximum errors between -1.0 degrees and 14.2 degrees). The double anatomical calibration implementation should be preferred since it reduces the kinematics errors to levels which are acceptable in most clinical applications.
引用
收藏
页码:94 / 103
页数:10
相关论文
共 50 条
  • [41] Objective assessment of laparoscopic suturing skills using a motion-tracking system
    Shohei Yamaguchi
    Daisuke Yoshida
    Hajime Kenmotsu
    Takefumi Yasunaga
    Kozo Konishi
    Satoshi Ieiri
    Hideaki Nakashima
    Kazuo Tanoue
    Makoto Hashizume
    [J]. Surgical Endoscopy, 2011, 25 : 771 - 775
  • [42] Machine learning for predicting accuracy of lung and liver tumor motion tracking using radiomic features
    Li, Guangjun
    Zhang, Xiangyu
    Song, Xinyu
    Duan, Lian
    Wang, Guangyu
    Xiao, Qing
    Li, Jing
    Liang, Lan
    Bai, Long
    Bai, Sen
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (03) : 1605 - 1618
  • [43] In vitro haploid production in sunflower genotypes and homozygosity assessment using microsatellite marker
    Patil, N. D.
    Bhalerao, S. R.
    [J]. RESEARCH JOURNAL OF BIOTECHNOLOGY, 2021, 16 (06): : 148 - 154
  • [44] Multi-species assessment of electrical resistance as a skin integrity marker for in vitro percutaneous absorption studies
    Davies, DJ
    Ward, RJ
    Heylings, JR
    [J]. TOXICOLOGY IN VITRO, 2004, 18 (03) : 351 - 358
  • [45] QUANTITATIVE IN-VITRO ASSESSMENT OF PHOTOTOXICITY USING A HUMAN SKIN MODEL, SKIN(2(TM))
    EDWARDS, SM
    DONNELLY, TA
    SAYRE, RM
    RHEINS, LA
    [J]. PHOTODERMATOLOGY PHOTOIMMUNOLOGY & PHOTOMEDICINE, 1994, 10 (03) : 111 - 117
  • [46] Concurrent assessment of gait kinematics using marker-based and markerless motion capture
    Kanko, M. Robert
    Laende, K. Elise
    Davis, M. Elysia
    Selbie, W. Scott
    Deluzio, J. Kevin
    [J]. JOURNAL OF BIOMECHANICS, 2021, 127
  • [47] Evaluation of Simulated Clinical Breast Exam Motion Patterns Using Marker-Less Video Tracking
    Azari, David P.
    Pugh, Carla M.
    Laufer, Shlomi
    Kwan, Calvin
    Chen, Chia-Hsiung
    Yen, Thomas Y.
    Hu, Yu Hen
    Radwin, Robert G.
    [J]. HUMAN FACTORS, 2016, 58 (03) : 427 - 440
  • [48] Accuracy assessment for navigated maxillo-facial surgery using an electromagnetic tracking device
    Seeberger, Robin
    Kane, Gavin
    Hoffmann, Juergen
    Eggers, Georg
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2012, 40 (02) : 156 - 161
  • [49] An Improved Correlation Model for Respiration Tracking in Robotic Radiosurgery Using Essential Skin Surface Motion
    Wang, Jiateng
    Sun, Rongchuan
    Yu, Shumei
    Zhang, Fengfeng
    Lining, Sun
    [J]. IEEE ROBOTICS AND AUTOMATION LETTERS, 2021, 6 (04) : 7886 - 7893
  • [50] Quantifying skin motion artifact error of the hindfoot and forefoot marker clusters with the optical tracking of a multi-segment foot model using single-plane fluoroscopy
    Shultz, R.
    Kedgley, A. E.
    Jenkyn, T. R.
    [J]. GAIT & POSTURE, 2011, 34 (01) : 44 - 48