Analysis of surfactants by capillary electrophoresis mass spectrometry

被引:0
|
作者
Tanaka, Y
Kishimoto, Y
Otsuka, K
Terabe, S
机构
[1] Nippon Boehringer Ingelheim Co Ltd, Kawanishi Pharm Res Inst, Dept Analyt Chem, Kawanishi, Hyogo 6660193, Japan
[2] Himeji Inst Technol, Fac Sci, Dept Mat Sci, Kamigori, Hyogo 6781297, Japan
关键词
capillary electrophoresis; mass spectrometry; electrospray ionization; surfactant; impurity;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Capillary electrophoresis/mass spectrometry (CE/MS) was applied to an analysis of surfactants. The detection limit of sodium dodecyl sulfate (SDS) was determined. Compared to indirect UV detection, SDS was detected with higher sensitivity by MS detection. The detection limit at a signal-to-noise ratio of 2 was 0.05 mu g/ml when an untreated fused-silica capillary was used. Sodium decyl sulfate and sodium tetradecyl sulfate were detected by CE/MS as impurities in SDS. CE/MS easily showed a difference in purities of commercial SDS among three different suppliers. Composition analyses of commercial surfactants (sodium polyoxyethylene(2) dodecyl ether sulfate and dodecyl dimethylaminoacetic acid betaine) were also performed by CE/MS. A number of components and impurities were identified according to each molecular mass. It has been shown that CE/MS is a promising analytical tool for the analysis of surfactants.
引用
收藏
页码:563 / 569
页数:7
相关论文
共 50 条
  • [31] Analysis of cationic surfactants by capillary electrophoresis
    Piera, E
    Erra, P
    Infante, MR
    JOURNAL OF CHROMATOGRAPHY A, 1997, 757 (1-2) : 275 - 280
  • [32] Metabolome analysis based on capillary electrophoresis-mass spectrometry
    Hirayama, Akiyoshi
    Wakayama, Masataka
    Soga, Tomoyoshi
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 61 : 215 - 222
  • [33] Analysis of Rauwolfia alkaloids employing capillary electrophoresis mass spectrometry
    Stockigt, D
    Unger, M
    Belder, D
    Stockigt, J
    NATURAL PRODUCT LETTERS, 1997, 9 (04): : 265 - 272
  • [34] Analysis of reduced and oxidized forms of cytochrome c by capillary electrophoresis and capillary electrophoresis-mass spectrometry
    He, T
    Chandramouli, N
    Fu, E
    Wu, A
    Wang, YK
    ANALYTICAL BIOCHEMISTRY, 1999, 271 (02) : 189 - 192
  • [35] General approach for the analysis of various alkaloid classes using capillary electrophoresis and capillary electrophoresis mass spectrometry
    Unger, M
    Stockigt, D
    Belder, D
    Stockigt, J
    JOURNAL OF CHROMATOGRAPHY A, 1997, 767 (1-2) : 263 - 276
  • [36] Analysis of Polymer Additives and Impurities by Liquid Chromatography/Mass Spectrometry and Capillary Electrophoresis/Mass Spectrometry
    Buchberger, Wolfgang
    Stiftinger, Martin
    MASS SPECTROMETRY OF POLYMERS - NEW TECHNIQUES, 2012, 248 : 39 - 67
  • [37] Intact mass analysis of monoclonal antibodies by capillary electrophoresis-Mass spectrometry
    Han, Mei
    Rock, Brooke M.
    Pearson, Josh T.
    Rock, Dan A.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1011 : 24 - 32
  • [38] Potential of capillary electrophoresis, tandem mass spectrometry and coupled capillary electrophoresis-tandem mass spectrometry as diagnostic tools
    Elgstoen, KBP
    Zhao, JY
    Anacleto, JF
    Jellum, E
    JOURNAL OF CHROMATOGRAPHY A, 2001, 914 (1-2) : 265 - 275
  • [39] Quantitation in capillary electrophoresis-mass spectrometry
    Ohnesorge, J
    Neusüss, C
    Wätzig, H
    ELECTROPHORESIS, 2005, 26 (21) : 3973 - 3987
  • [40] Nonaqueous capillary electrophoresis-mass spectrometry
    Scriba, Gerhard K. E.
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1159 (1-2) : 28 - 41