Hygrothermal performance of a masonry wall retrofitted with interior insulation

被引:0
|
作者
Saïd, MNA [1 ]
Demers, RG [1 ]
McSheffrey, LL [1 ]
机构
[1] Natl Res Council Canada, Inst Res Construct, Ottawa, ON, Canada
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A 4-storey masonry building was retrofitted and converted to offices. The wall retrofit included the addition of insulation and vapour and air barriers on the inside of the brick wall. A section of the retrofitted wall was continuously monitored for over two years. This paper describes the monitoring program and discusses the hygrothermal performance of the retrofitted masonry wall. The retrofit had a negligible effect on the drying potential of the brick wall during the summer months but reduced the wall drying potential during the winter months. The cooling rate of the brick mean temperature, at temperatures below 0degreesC, increased to -3.4degreesC/hr as compared to -2.7degreesC/hr for the uninsulated wall case. The moisture level in the brick wall increased, which was partially due to the retrofit and partially due to a wetter weather during the monitoring period. As a result of increased moisture level in the brick, the RSI-value of the brick wall decreased from an average of 0.31 in the first winter following the retrofit to an average value of 0.18 in the second winter months. The brick wall may be at a higher risk of frost damage than before the retrofit.
引用
收藏
页码:445 / 454
页数:10
相关论文
共 50 条
  • [31] Effect of climate change on hygrothermal performance of timber framed wall with different insulation materials
    Schroderus, Santeri
    Lähteenmäki, Veli-Matti
    Barbero-López, Aitor
    Haapala, Antti
    Fedorik, Filip
    [J]. Building and Environment, 2025, 269
  • [32] Hygrothermal Assessment of Insulation Systems for Internal Insulation of Solid Masonry Walls under Various Conditions
    Freimanis, Ritvars
    Vanaga, Ruta
    Balodis, Viesturs
    Zundans, Zigmars
    Blumberga, Andra
    [J]. BUILDINGS, 2023, 13 (10)
  • [33] In-plane seismic performance of masonry wall retrofitted with prestressed steel-bar truss
    Hwang, Seung-Hyeon
    Kim, Sanghee
    Yang, Keun-Hyeok
    [J]. EARTHQUAKES AND STRUCTURES, 2020, 19 (06) : 459 - 469
  • [34] Hygrothermal performance of a brick wall with interior insulation in cold climate: Vapour open versus vapour tight approach (vol 46, pg 3, 2022)
    Kloseiko, P.
    Kalamees, T.
    [J]. JOURNAL OF BUILDING PHYSICS, 2022,
  • [35] Cooling energy performance and installation of a retrofitted exterior insulation and finish system on masonry residences in the Southwestern United States
    Ternes, Mark P.
    Wilkes, Kenneth E.
    McLain, Howard A.
    [J]. ASTM Special Technical Publication, 1995, (1187): : 257 - 274
  • [36] Hygrothermal performance of straw bales split-insulation wall assembly in cold and humid climates
    Chen, Yuchen
    Wang, Xiaodong Alice
    Li, Dehong
    Rodrigue, Denis
    Gosselin, Louis
    [J]. ENERGY AND BUILDINGS, 2024, 307
  • [37] Interior Insulation of Masonry Walls-Selected Problems in the Design
    Orlik-Kozdon, Bozena
    [J]. ENERGIES, 2019, 12 (20)
  • [38] Hygrothermal performance of micro inhomogeneous insulation materials- EPS-based wall panel
    Kathiravel, Rojini
    Weerasinghe, Pasindu
    Jayasinghe, M. T. R.
    [J]. JOURNAL OF BUILDING ENGINEERING, 2024, 92
  • [39] Influence of envelope properties on interior insulation solutions for masonry walls
    Zhou, Xiaohai
    Carmeliet, Jan
    Derome, Dominique
    [J]. BUILDING AND ENVIRONMENT, 2018, 135 : 246 - 256
  • [40] Seismic In-plane performance of retrofitted masonry walls
    Farooq, S. H.
    Mohamed, A. ElGawady
    Ilyas, M.
    [J]. KSCE JOURNAL OF CIVIL ENGINEERING, 2014, 18 (01) : 226 - 237