Modified Y-TZP Core Design Improves All-ceramic Crown Reliability

被引:77
|
作者
Silva, N. R. F. A. [2 ]
Bonfante, E. A. [1 ]
Rafferty, B. T. [1 ]
Zavanelli, R. A. [1 ]
Rekow, E. D. [3 ]
Thompson, V. P. [1 ]
Coelho, P. G. [1 ]
机构
[1] NYU, Coll Dent, Dept Biomat & Biomimet, New York, NY 10010 USA
[2] NYU, Coll Dent, Dept Prosthodont, New York, NY 10010 USA
[3] NYU, Coll Dent, Dept Basic Sci, New York, NY 10010 USA
关键词
all-ceramic crown; mechanical testing; step-stress fatigue; core design; CLINICAL SUCCESS; DAMAGE MAPS; ZIRCONIA; PORCELAIN; FAILURE; RECONSTRUCTIONS; RESTORATIONS;
D O I
10.1177/0022034510384617
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study tested the hypothesis that all-ceramic core-veneer system crown reliability is improved by modification of the core design. We modeled a tooth preparation by reducing the height of proximal walls by 1.5 mm and the occlusal surface by 2.0 mm. The CAD-based tooth preparation was replicated and positioned in a dental articulator for core and veneer fabrication. Standard (0.5 mm uniform thickness) and modified (2.5 mm height lingual and proximal cervical areas) core designs were produced, followed by the application of veneer porcelain for a total thickness of 1.5 mm. The crowns were cemented to 30-day-aged composite dies and were either single-load-to-failure or step-stress-accelerated fatigue-tested. Use of level probability plots showed significantly higher reliability for the modified core design group. The fatigue fracture modes were veneer chipping not exposing the core for the standard group, and exposing the veneer core interface for the modified group.
引用
下载
收藏
页码:104 / 108
页数:5
相关论文
共 50 条
  • [21] Fatigue behavior of Y-TZP ceramic after surface treatments
    Amaral, Marina
    Cesar, Paulo Francisco
    Bottino, Marco Antonio
    Lohbauer, Ulrich
    Valandro, Luiz Felipe
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2016, 57 : 149 - 156
  • [22] All-ceramic crown preparations: An alternative technique
    Tran, J.
    Dudley, J.
    Richards, L.
    AUSTRALIAN DENTAL JOURNAL, 2017, 62 (01) : 65 - 70
  • [23] A COMPRESSIVE STRENGTH STUDY OF AN ALL-CERAMIC CROWN
    JOSEPHSON, BA
    SCHULMAN, A
    DUNN, ZA
    HURWITZ, W
    JOURNAL OF PROSTHETIC DENTISTRY, 1985, 53 (03): : 301 - 303
  • [24] Low Temperature Degradation of Y-TZP Ceramic for Dental Applications
    Wu, Zhi-kai
    Li, Ning
    Zhao, Wan-qian
    Yan, Jia-zhen
    EIGHTH CHINA NATIONAL CONFERENCE ON FUNCTIONAL MATERIALS AND APPLICATIONS, 2014, 873 : 241 - 249
  • [25] Study on preparation of Y-TZP ceramic matrix for dental prosthesis
    Yang Sefei
    Jin Zhihao
    Guo Tianwen
    RARE METAL MATERIALS AND ENGINEERING, 2007, 36 (02) : 313 - 317
  • [26] The anterior all-ceramic crown: a rationale for the choice of ceramic and cement
    Mizrahi, B.
    BRITISH DENTAL JOURNAL, 2008, 205 (05) : 251 - 255
  • [27] The anterior all-ceramic crown: a rationale for the choice of ceramic and cement
    B. Mizrahi
    British Dental Journal, 2008, 205 : 251 - 255
  • [28] Damage and Reliability of Y-TZP after Cementation Surface Treatment
    Guess, P. C.
    Zhang, Y.
    Kim, J. -W.
    Rekow, E. D.
    Thompson, V. P.
    JOURNAL OF DENTAL RESEARCH, 2010, 89 (06) : 592 - 596
  • [29] Reliability and Failure Modes of Two Y-TZP Abutment Designs
    Mitsias, Miltiadis E.
    Thompson, Van P.
    Pines, Mitchel
    Silva, Nelson R. F. A.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2015, 28 (01) : 75 - 78
  • [30] Effect of Veneering Techniques on Damage and Reliability of Y-TZP Trilayers
    Guess, Petra C.
    INTERNATIONAL JOURNAL OF ESTHETIC DENTISTRY, 2009, 4 (03): : 262 - 276