Automatic arteriovenous crossing phenomenon detection on retinal fundus images

被引:3
|
作者
Hatanaka, Yuji [1 ]
Muramatsu, Chisako [2 ]
Hara, Takeshi [2 ]
Fujita, Hiroshi [2 ]
机构
[1] Univ Shiga Prefecture, Dept Elect Syst Engn, Sch Engn, 2500 Hassaka Cho, Hikone, Shiga 5228533, Japan
[2] Gifu Univ, Grad Sch Med, Depr Intelligent Image Informat, Div Regenerat & Adv Med Sci, Gifu 5011194, Japan
关键词
Arteriolosclerosis; Hypertensive retinopathy; Retinal Fundus image; Arteriovenous crossing phenomenon; Blood vessel width measurement; Computer-aided diagnosis; VESSEL SEGMENTATION; BLOOD-VESSELS; ALGORITHM;
D O I
10.1117/12.877232
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Arteriolosclerosis is one cause of acquired blindness. Retinal fundus image examination is useful for early detection of arteriolosclerosis. In order to diagnose the presence of arteriolosclerosis, the physicians find the silver-wire arteries, the copper-wire arteries and arteriovenous crossing phenomenon on retinal fundus images. The focus of this study was to develop the automated detection method of the arteriovenous crossing phenomenon on the retinal images. The blood vessel regions were detected by using a double ring filter, and the crossing sections of artery and vein were detected by using a ring filter. The center of that ring was an interest point, and that point was determined as a crossing section when there were over four blood vessel segments on that ring. And two blood vessels gone through on the ring were classified into artery and vein by using the pixel values on red and blue component image. Finally, V-2-to-V-1 ratio was measured for recognition of abnormalities. V-1 was the venous diameter far from the blood vessel crossing section, and V-2 was the venous diameter near from the blood vessel crossing section. The crossing section with V-2-to-V-1 ratio over 0.8 was experimentally determined as abnormality. Twenty four images, including 27 abnormalities and 54 normal crossing sections, were used for preliminary evaluation of the proposed method. The proposed method was detected 73% of crossing sections when the 2.8 sections per image were mis-detected. And, 59% of abnormalities were detected by measurement of V-1-to-V-2 ratio when the 1.7 sections per image were mis-detected.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Automatic Generation of Synthetic Retinal Fundus Images: Vascular Network
    Bonaldi, Lorenza
    Menti, Elisa
    Ballerini, Lucia
    Ruggeri, Alfredo
    Trucco, Emanuele
    [J]. 20TH CONFERENCE ON MEDICAL IMAGE UNDERSTANDING AND ANALYSIS (MIUA 2016), 2016, 90 : 54 - 60
  • [42] An efficient microaneurysms detection approach in retinal fundus images
    Mohan, N. Jagan
    Murugan, R.
    Goel, Tripti
    Tanveer, M.
    Roy, Parthapratim
    [J]. INTERNATIONAL JOURNAL OF MACHINE LEARNING AND CYBERNETICS, 2023, 14 (04) : 1235 - 1252
  • [43] An efficient microaneurysms detection approach in retinal fundus images
    N. Jagan Mohan
    R. Murugan
    Tripti Goel
    M. Tanveer
    Parthapratim Roy
    [J]. International Journal of Machine Learning and Cybernetics, 2023, 14 : 1235 - 1252
  • [44] Retinal Hemorrhage Detection Using Splat Segmentation of Retinal Fundus Images
    Kurale, Nishigandha G.
    Vaidya, M. V.
    [J]. 2017 INTERNATIONAL CONFERENCE ON COMPUTING, COMMUNICATION, CONTROL AND AUTOMATION (ICCUBEA), 2017,
  • [45] Automated detection and segmentation of drusen in retinal fundus images
    Mittal, Deepti
    Kumari, Kajal
    [J]. COMPUTERS & ELECTRICAL ENGINEERING, 2015, 47 : 82 - 95
  • [46] Automatic Detection of Glaucoma in Retinal Images
    Xiong, Li
    Li, Huiqi
    Zheng, Yan
    [J]. PROCEEDINGS OF THE 2014 9TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2014, : 1016 - +
  • [47] Automatic Change Detection of Retinal Images
    Troglio, G.
    Nappo, A.
    Benediktsson, J. A.
    Moser, G.
    Serpico, S. B.
    Stefansson, E.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 11: BIOMEDICAL ENGINEERING FOR AUDIOLOGY, OPHTHALMOLOGY, EMERGENCY AND DENTAL MEDICINE, 2009, 25 (11): : 281 - +
  • [48] AUTOMATIC NOTCH DETECTION IN RETINAL IMAGES
    Tan, Mei Hui
    Sun, Ying
    Ong, Sim Heng
    Liu, Jiang
    Baskaran, Mani
    Aung, Tin
    Wong, Tien Yin
    [J]. 2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 1440 - 1443
  • [49] Automatic Detection of Microaneurysms and Hemorrhages in Digital Fundus Images
    Giri Babu Kande
    T. Satya Savithri
    P. Venkata Subbaiah
    [J]. Journal of Digital Imaging, 2010, 23 : 430 - 437
  • [50] Automatic Glaucoma Detection from Stereo Fundus Images
    Ong, Ee Ping
    Cheng, Jun
    Wong, Damon W. K.
    Tay, Elton L. T.
    Teo, Hwei Yee
    Loo, Rosalyn Grace
    Yip, Leonard W. L.
    [J]. 42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 1540 - 1543