Making the Case for Absorbed Radiation Response Biodosimetry - Utility of a High-Throughput Biodosimetry System

被引:2
|
作者
Hoffmeyer, Michaela R. [1 ]
Gillis, Kristin [2 ]
Park, Jin G. [2 ]
Murugan, Vel [2 ]
LaBaer, Joshua [2 ]
机构
[1] MRIGlobal, Global Hlth Surveillance & Diagnost, Kansas City, MO USA
[2] Arizona State Univ, Biodesign Inst, Tempe, AZ USA
关键词
NONHUMAN PRIMATE MODEL; EARLY DOSE ASSESSMENT; MEDICAL-MANAGEMENT; NUCLEAR DETONATION; IMPROVES SURVIVAL; H-ARS; PREDICTION; INJURIES;
D O I
10.1667/RADE-20-00029.1
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
There is an unmet need to provide medical personnel with a Food and Drug Administration (FDA)-approved biodosimetry method for quantifying individualized absorbed dose response to inform treatment decisions for a very large patient population potentially exposed to ionizing radiation in the event of a nuclear incident. Validation of biodosimetry devices requires comparison of absorbed dose estimates to delivered dose as an indication of accuracy; however, comparison to delivered dose does not account for biological variability or an individual's radiosensitivity. As there is no FDA-cleared gene-expression-based biodosimetry method for determining biological response to radiation, results from accuracy comparisons to delivered dose yield relatively wide tolerance intervals or uncertainty. The Arizona State University Biodesign Institute is developing a high-throughput, automated real-time polymerase chain reaction (RTPCR)-based biodosimetry system that provides absorbed dose estimates for patients exposed to 0-10 Gy from blood collected 1-7 days postirradiation. While the absorbed dose estimates result from a calibration against the actual exposed dose, the reported dose estimate is a measure of response to absorbed dose based on the exposure models used in developing the system. A central concern with biodosimetry test evaluation is how variability in the dose estimate results could affect medical decision-making, and if the biodosimetry test system performance is quantitatively sufficient to inform effective treatment. A risk:benefit analysis of the expected system performance in the proposed intended use environment was performed to address the potential medical utility of this biodosimetry system. Uncertainty analysis is based on biomarker variability in non-human primate (NHP) models. Monte Carlo simulation was employed to test multiple groups of biomarkers and their potential variation in response to determine uncertainty associated with dose estimate results. Dose estimate uncertainty ranges from 61.2-1.7 Gy depending on the exposure dose over a range of 2-10 Gy. The risk:benefit of individualized absorbed dose estimates within the context of medical interventions after a nuclear incident is considered and the application of the biodosimetry system is evaluated in this framework. NHP dose-response relationships, as measured by clinical outcome end points, show expected biological and radiosensitivity responses in the primate populations tested and corroborate the biological variability observed in the reported absorbed dose estimate. Performance is examined in relationship to current clinical management and treatment recommendations, with evaluation of potential patient risk in over- and underestimating absorbed dose. (C) 2021 by Radiation Research Society
引用
收藏
页码:535 / 546
页数:12
相关论文
共 50 条
  • [41] PROPOSED TRIAGE CATEGORIES FOR LARGE-SCALE RADIATION INCIDENTS USING HIGH-ACCURACY BIODOSIMETRY METHODS
    Rea, Michael E.
    Gougelet, Robert M.
    Nicolalde, Roberto J.
    Geiling, James A.
    Swartz, Harold M.
    HEALTH PHYSICS, 2010, 98 (02): : 136 - 144
  • [42] Development of an automated high-throughput screening system: a case history
    Harding, D
    Banks, M
    Fogarty, S
    Binnie, A
    DRUG DISCOVERY TODAY, 1997, 2 (09) : 385 - 390
  • [43] High-throughput metabolism: making the most of the technology
    Smith, D
    DRUG DISCOVERY TODAY, 2001, 6 (11) : 564 - 564
  • [44] Influences of TP53 expression on cellular radiation response and its relevance to diagnostic biodosimetry for mission environmental monitoring
    Lu-Hesselmann, J.
    van Beuningen, D.
    Meineke, V.
    Franke, E.
    RADIATION PROTECTION DOSIMETRY, 2006, 122 (1-4) : 237 - 243
  • [45] Biological effects of millimeter-wave radiation: A high-throughput screening system
    Pooley, DT
    Gibson, C
    Stewart, WR
    Magee, J
    Ellison, BN
    Lloyd, D
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (03): : 1296 - 1302
  • [46] HIGH-THROUGHPUT DNA PREPARATION SYSTEM
    GARNER, HR
    ARMSTRONG, B
    KRAMARSKY, DA
    GENETIC ANALYSIS-BIOMOLECULAR ENGINEERING, 1992, 9 (5-6): : 134 - 139
  • [47] Microfluidic system for high-throughput proteomics
    Le Gac, S
    Arscott, S
    Druon, C
    Tabourier, P
    Rolando, C
    NANOTECH 2003, VOL 1, 2003, : 70 - 73
  • [48] High-throughput genotyping: A complete system
    Nanthakumar, E
    Cunha, W
    Ederer, G
    Manaster, C
    Roter, A
    Gurevitch, D
    Watson, A
    Idury, R
    Cardon, L
    Hall, J
    AMERICAN JOURNAL OF HUMAN GENETICS, 1997, 61 (04) : A287 - A287
  • [49] Utility of high-throughput DNA sequencing in the study of the human papillomaviruses
    Escobar-Escamilla, Noe
    Ernesto Ramirez-Gonzalez, Jose
    Castro-Escarpulli, Graciela
    Alberto Diaz-Quinonez, Jose
    VIRUS GENES, 2018, 54 (01) : 17 - 24
  • [50] Utility of high-throughput DNA sequencing in the study of the human papillomaviruses
    Noé Escobar-Escamilla
    José Ernesto Ramírez-González
    Graciela Castro-Escarpulli
    José Alberto Díaz-Quiñonez
    Virus Genes, 2018, 54 : 17 - 24