Cyclodextrins as a chiral mobile phase additive in nano-liquid chromatography: comparison of reversed-phase silica monolithic and particulate capillary columns

被引:32
|
作者
Rocco, Anna [1 ,2 ]
Maruska, Audrius [1 ]
Fanali, Salvatore [2 ]
机构
[1] Vytautas Magnus Univ, Dept Chem, LT-44404 Kaunas, Lithuania
[2] CNR, Ist Metodol Chim, Area Ric Roma 1, I-00015 Rome, Italy
关键词
Enantioseparations; Nano-liquid chromatography; Monolithic column; Chiral mobile phase additive; Cyclodextrins; NSAIDs; NONSTEROIDAL ANTIINFLAMMATORY DRUGS; HYDROXYPROPYL-BETA-CYCLODEXTRIN; ENANTIOMERIC SEPARATION; SELECTOR; HPLC;
D O I
10.1007/s00216-012-5764-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Enantioseparations of racemic nonsteroidal anti-inflammatory drugs (naproxen, ibuprofen, ketoprofen, flurbiprofen, suprofen, indoprofen, cicloprofen, and carprofen) were performed by nano-liquid chromatography, employing achiral capillary columns and heptakis(2,3,6-tri-O-methyl)-beta-cyclodextrin (TM-beta-CD) or hydroxylpropyl-beta-cyclodextrin (HP-beta-CD) as a chiral mobile phase additive (CMPA). Working under the same experimental conditions (in terms of mobile phase and linear velocity), the performance of a RP-C18 monolithic column was compared with that of a RP-C18 packed column of the same dimensions (100 mu m i.d. x 10 cm). Utilizing a mobile phase composed of 30% ACN (v/v) buffered with 50 mM sodium acetate at pH 3, and containing 30 mM TM-beta-CD, the monolithic column provided faster analysis but lower resolution than the packed column. This behavior was ascribed to the high permeability of the monolithic column, as well as to its minor selectivity. HP-beta-CD was chosen as an alternative to TM-beta-CD. Employing the monolithic column, the effects of different parameters such as HP-beta-CD concentration, mobile phase composition, and pH on the retention factor and the chiral resolution of the analytes were studied. For the most of the analytes, enantioresolution (which ranged from R (s) = 1.80 for naproxen to R (s) = 0.86 for flurbiprofen) was obtained with a mobile phase consisting of sodium acetate buffer (25 mM, pH 3), 10% MeOH, and 15 mM HP-beta-CD. When the same experimental conditions were used with the packed column, no compound eluted within 1 h. Upon increasing the percentage of organic modifier to favor analyte elution, only suprofen eluted within 30 min, with an R (s) value of 1.14 (20% MeOH). Replacing MeOH with ACN resulted in a loss of enantioresolution, except for naproxen (R (s) = 0.89).
引用
收藏
页码:2935 / 2943
页数:9
相关论文
共 50 条
  • [31] Resolution of enantiomers of tropicamide by reversed-phase high performance liquid chromatography using hydroxypropyl-β-cyclodextrin as chiral mobile phase additive
    Hefnawy, MM
    Stewart, JT
    ANALYTICAL LETTERS, 1998, 31 (04) : 659 - 667
  • [32] Mobile Phase Effects in Reversed-Phase and Hydrophilic Interaction Liquid Chromatography
    Jandera, Pavel
    Hajek, Tarns
    ADVANCES IN CHROMATOGRAPHY, VOL 57, 2021, 57 : 1 - 58
  • [33] Preparation and Chromatographic Evaluation of Columns for Reversed-Phase Liquid Chromatography
    Zhang, Mengyao
    Wang, Haibo
    Chen, Hui
    Sun, Xiaoli
    Jiang, Ru
    ACTA CHIMICA SLOVENICA, 2011, 58 (01) : 60 - 68
  • [34] Preparation of high efficiency and highly retentive monolithic silica capillary columns for reversed-phase chromatography by chemical modification by polymerization of octadecyl methacrylate
    Nunez, Oscar
    Ikegami, Tohru
    Kajiwara, Wataru
    Miyamoto, Kosuke
    Horie, Kanta
    Tanaka, Nobuo
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1156 (1-2) : 35 - 44
  • [35] Comparison of ethylammonium formate to methanol as a mobile-phase modifier for reversed-phase liquid chromatography
    Waichigo, MM
    Danielson, ND
    JOURNAL OF SEPARATION SCIENCE, 2006, 29 (05) : 599 - 606
  • [36] Simultaneous determination of three alkaloids in Huangbo using an ionic liquid as a mobile phase additive in reversed-phase liquid chromatography
    Ding, Xiaoyuan
    Tang, Yan
    Sun, Ailing
    Liu, Renmin
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (03) : 374 - 380
  • [37] COMPARISON OF REVERSED-PHASE LIQUID-CHROMATOGRAPHY COLUMNS USING ROHRSCHNEIDER TYPE CONSTANTS
    SMITH, RM
    JOURNAL OF CHROMATOGRAPHY, 1982, 236 (02): : 321 - 328
  • [38] Enantiomeric separation of linezolid by chiral reversed-phase liquid chromatography
    Nirogi, Ramakrishna
    Kota, Srinivasulu
    Katta, Raja Rajeswari
    Vennila, Saritha
    Kanclikere, Vishwottam
    Mudigonda, Koteshwara
    Vurimindi, Hima Bindu
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2008, 46 (09) : 764 - 766
  • [39] CYCLODEXTRINS AS MOBILE-PHASE COMPONENTS FOR SEPARATION OF ISOMERS BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    SYBILSKA, D
    ACS SYMPOSIUM SERIES, 1987, 342 : 218 - 234
  • [40] Preparation of a monolithic column with a mixed-mode stationary phase of reversed-phase/hydrophilic interaction for capillary liquid chromatography
    Zhang, Meng
    Gong, Li
    Liu, Guizhen
    Kang, Jingwu
    JOURNAL OF SEPARATION SCIENCE, 2019, 42 (03) : 662 - 669