Evaluation of Stopping-Power Prediction by Dual- and Single-Energy Computed Tomography in an Anthropomorphic Ground-Truth Phantom

被引:71
|
作者
Wohlfahrt, Patrick [1 ,2 ,3 ]
Moehler, Christian [4 ,5 ]
Richter, Christian [1 ,2 ,3 ,6 ,7 ,8 ]
Greilich, Steffen [4 ,5 ]
机构
[1] Tech Univ Dresden, Helmholtz Zentrum Dresden Rossendorf, Fac Med, OncoRay Natl Ctr Radiat Res Oncol, Dresden, Germany
[2] Tech Univ Dresden, Helmholtz Zentrum Dresden Rossendorf, Univ Hosp Carl Gustav Carus, Dresden, Germany
[3] Helmholtz Zentrum Dresden Rossendorf, Inst Radiooncol OncoRay, Dresden, Germany
[4] German Canc Res Ctr, Heidelberg, Germany
[5] Heidelberg Inst Radiat Oncol HIRO, Natl Ctr Radiat Res Oncol NCRO, Heidelberg, Germany
[6] Tech Univ Dresden, Fac Med, Dept Radiotherapy & Radiat Oncol, Dresden, Germany
[7] Tech Univ Dresden, Univ Hosp Carl Gustav Carus, Dresden, Germany
[8] German Canc Consortium DKTK, Partner Site Dresden, Dresden, Germany
关键词
MULTILAYER IONIZATION-CHAMBER; PROTON RANGE VERIFICATION; STOICHIOMETRIC CALIBRATION; CT SCANS; THERAPY; UNCERTAINTIES; RADIOGRAPHY; PRECISION; RADIATION; ACCURACY;
D O I
10.1016/j.ijrobp.2017.09.025
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To determine the accuracy of particle range prediction for proton and heavier ion radiation therapy based on dual-energy computed tomography (DECT) in a realistic inhomogeneous geometry and to compare it with the state-of-the-art clinical approach. Methods and Materials: A 3-dimensional ground-truth map of stopping-power ratios (SPRs) was created for an anthropomorphic head phantom by assigning measured SPR values to segmented structures in a high-resolution CT scan. This reference map was validated independently comparing proton transmission measurements with Monte Carlo transport simulations. Two DECT-based methods for direct SPR prediction via the Bethe formula (DirectSPR) and 2 established approaches based on Hounsfield look-up tables (HLUTs) were chosen for evaluation. The SPR predictions from the 4 investigated methods were compared with the reference, using material-specific voxel statistics and 2-dimensional gamma analysis. Furthermore, range deviations were analyzed in an exemplary proton treatment plan. Results: The established reference SPR map was successfully validated for the discrimination of SPR and range differences well below 0.3% and 1 mm, respectively, even in complex inhomogeneous settings. For the phantom materials of larger volume (mainly brain, soft tissue), the investigated methods were overall able to predict SPR within 1% median deviation. The DirectSPR methods generally performed better than the HLUT approaches. For smaller phantom parts (such as cortical bone, air cavities), all methods were affected by image smoothing, leading to considerable SPR under-or overestimation. This effect was superimposed on the general SPR prediction accuracy in the exemplary treatment plan. Conclusions: DirectSPR predictions proved to be more robust, with high accuracy in particular for larger volumes. In contrast, HLUT approaches exhibited a fortuitous component. The evaluation of accuracy in a realistic phantom with validated ground-truth SPR represents a crucial step toward possible clinical application of DECT-based SPR prediction methods. (C) 2017 The Author(s). Published by Elsevier Inc.
引用
收藏
页码:244 / 253
页数:10
相关论文
共 50 条
  • [1] Experimental verification of stopping-power prediction from single- and dual-energy computed tomography in biological tissues
    Moehler, Christian
    Russ, Tom
    Wohlfahrt, Patrick
    Elter, Alina
    Runz, Armin
    Richter, Christian
    Greilich, Steffen
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (02):
  • [2] EXPERIMENTAL EXAMINATION OF RADIATION DOSES OF DUAL- AND SINGLE-ENERGY COMPUTED TOMOGRAPHY IN CHEST AND UPPER ABDOMEN IN A PHANTOM STUDY
    Bos, Denise
    Koenig, Britta
    Blex, Sebastian
    Zensen, Sebastian
    Opitz, Marcel
    Maier, Sandra
    Forsting, Michael
    Zylka, Waldemar
    Kuehl, Hilmar
    Wetter, Axel
    Guberina, Nika
    RADIATION PROTECTION DOSIMETRY, 2021, 193 (3-4) : 237 - 246
  • [3] Dosimetric Comparison between Single-energy Computed Tomography and Dual-energy Computed Tomography Relative to Stopping Power Estimation in Proton Therapy
    Chirdchid, Thamonwan
    Ruangchan, Sirinya
    Sanghangthum, Taweap
    JOURNAL OF MEDICAL PHYSICS, 2023, 48 (03) : 292 - 297
  • [4] Accuracy of Dual-Energy Computed Tomography Techniques for Fat Quantification in Comparison With Magnetic Resonance Proton Density Fat Fraction and Single-Energy Computed Tomography in an Anthropomorphic Phantom Environment
    Wu, Zi Jun
    Hippe, Daniel S.
    Zamora, David A.
    Briller, Noah
    Amin, Kathan A.
    Kolokythas, Orpheus
    Mileto, Achille
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2021, 45 (06) : 877 - 887
  • [5] A comparison of relative proton stopping power measurements across patient size using dual- and single-energy CT
    Michalak, Gregory
    Taasti, Vicki
    Krauss, Bernhard
    Deisher, Amanda
    Halaweish, Ahmed
    McCollough, Cynthia
    ACTA ONCOLOGICA, 2017, 56 (11) : 1465 - 1471
  • [6] Dual- and multi-energy CT for particle stopping-power estimation: current state, challenges and potential
    Yang, Ming
    Wohlfahrt, Patrick
    Shen, Chenyang
    Bouchard, Hugo
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (04):
  • [7] Dual-Energy Computed Tomography: Is There a Penalty in Image Quality and Radiation Dose Compared With Single-Energy Computed Tomography?
    Thomas, Christoph
    Ketelsen, Dominik
    Tsiflikas, Ilias
    Reimann, Anja
    Brodoefel, Harald
    Claussen, Claus D.
    Heuschmid, Martin
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (02) : 309 - 315
  • [8] Performance of single-energy metal artifact reduction in cardiac computed tomography: A clinical and phantom study
    Groves, Daniel W.
    Acharya, Tushar
    Steveson, Chloe
    Schuzer, John L.
    Rollison, Shirley F.
    Nelson, Evan A.
    Sirajuddin, Arlene
    Sathya, Bharath
    Bronson, Kathie
    Shanbhag, Sujata M.
    Chen, Marcus Y.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2020, 14 (06) : 510 - 515
  • [9] Stopping-power ratio estimation for proton radiotherapy using dual-energy computed tomography and prior-image constrained denoising
    Zimmerman, Jens
    Thor, Daniel
    Poludniowski, Gavin
    MEDICAL PHYSICS, 2023, 50 (03) : 1481 - 1495
  • [10] Effect of extended field-of-view approaches on the accuracy of stopping power ratio estimation for single-energy computed tomography simulators
    Lin, Chang-Shiun
    Tsai, Yi-Chun
    Chen, Liang-Hsin
    Wang, Chun-Wei
    Wu, Chia-Jung
    Chen, Wan-Yu
    Liang, Hsiang-Kung
    Kuo, Sung-Hsin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (09):