Comparison of open versus percutaneous pedicle screw insertion in a sheep model

被引:57
|
作者
Lehmann, W. [1 ]
Ushmaev, A. [1 ]
Ruecker, A. [1 ]
Nuechtern, J. [1 ]
Grossterlinden, L. [1 ]
Begemann, P. G. [2 ]
Baeumer, T. [3 ]
Rueger, J. M. [1 ]
Briem, D. [1 ]
机构
[1] Univ Hamburg, Sch Med, Dept Trauma Hand & Reconstruct Surg, D-20246 Hamburg, Germany
[2] Univ Hamburg, Sch Med, Dept Diagnost & Intervent Radiol, D-20246 Hamburg, Germany
[3] Univ Hamburg, Sch Med, Dept Neurol, D-20246 Hamburg, Germany
关键词
spine; minimal-invasive surgery; pedicle screw; animal study;
D O I
10.1007/s00586-008-0652-7
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Minimally invasive surgery has become more and more important for the treatment of traumatic spine fractures. Besides, some clinical studies, objective data regarding the possible lower damage to the surrounding tissue of the spine is still missing. Here we report a sheep model where we compared a percutaneous versus an open approach for dorsal instrumentation with pedicle screws to the spine. Twelve skeletally mature sheep underwent bilateral pedicle screw fixation at the L4-L6 level. Forty-eight pedicle screws were bilaterally inserted into the pedicles and connected with rods using either an open dorsal standard or a percutaneous approach. Operation time, blood flow, compartment pressure, radiation time, loss of blood, laboratory findings and EMG were evaluated to objectify possible advantages for the percutaneous operation technique. Loss of blood and the distribution of CK-MM as a marker for muscle damage were significantly lower in the percutaneous group. However, radiation time was significantly longer in the percutaneous group. Other parameters like compartment pressure, blood flow and also measurement of the EMG at different time points did not reveal significant differences. Based on the results we found in the present study, percutaneous screw insertion can bring moderate advantages but it should be noted that essential functional deficits to the muscle could not be detected.
引用
收藏
页码:857 / 863
页数:7
相关论文
共 50 条
  • [41] Comparison of Superior-Level Facet Joint Violations During Open and Percutaneous Pedicle Screw Placement
    Babu, Ranjith
    Park, Jong G.
    Mehta, Ankit I.
    Shan, Tony
    Grossi, Peter M.
    Brown, Christopher R.
    Richardson, William J.
    Isaacs, Robert E.
    Bagley, Carlos A.
    Kuchibhatla, Maragatha
    Gottfried, Oren N.
    NEUROSURGERY, 2012, 71 (05) : 962 - 969
  • [42] Lumbar Percutaneous Pedicle Screw Breach Rates A Comparison of Robotic Navigation Platform Versus Conventional Techniques
    Panchmatia, Jaykar R.
    Vaccaro, Alexander R.
    Wang Wenhai
    Harris, Jonathan A.
    Bucklen, Brandon S.
    CLINICAL SPINE SURGERY, 2020, 33 (04): : E162 - E167
  • [43] Pedicle Screw Insertion Surgical Simulator
    Du, Zhechen
    Zeller, Reihard
    Wang, David
    Zabjek, Karl
    DIGITAL HUMAN MODELING: APPLICATIONS IN HEALTH, SAFETY, ERGONOMICS, AND RISK MANAGEMENT, 2018, 10917 : 395 - 409
  • [44] Navigation system for pedicle screw insertion
    Denis, F
    Gautier, H
    Baskurt, A
    CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 1154 - 1154
  • [45] Comparison of outcome between percutaneous pedicle screw fixation and the Mini-Open Wiltse Approach with pedicle screw fixation for neurologically intact thoracolumbar fractures: A retrospective study
    Sheng, Wenbo
    Jiang, Haitao
    Hong, Chao
    Hu, Hongkui
    Yuan, Hantao
    Gu, Xiaohua
    Li, Sibo
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2022, 27 (03) : 594 - 599
  • [46] Slippage reduction of lumbar spondylolisthesis using percutaneous pedicle screw with reduction fixation system after interbody fusion: A comparison with traditional open fusion and pedicle screw fixation
    Heo, Dong-Hwa
    Jang, Jae-Won
    Lee, Jung-Kil
    Park, Choon-Keun
    JOURNAL OF CLINICAL NEUROSCIENCE, 2019, 67 : 156 - 162
  • [47] Krag Versus Caudad Trajectory Technique for Pedicle Screw Insertion in Osteoporotic Vertebrae
    Yuan, Qiang
    Han, Xiaoguang
    Han, Xiao
    He, Da
    Liu, Bo
    Tian, Wei
    SPINE, 2014, 39 (26B) : B27 - B35
  • [48] Comparison of Superior-Level Facet Joint Violations During Open and Percutaneous Pedicle Screw Placement COMMENTS
    Refai, Daniel
    Tu, Tsung-Hsi
    Mummaneni, Praveen
    NEUROSURGERY, 2012, 71 (05) : 969 - 970
  • [49] Percutaneous cortical bone trajectory screw fixation versus traditional open pedicle screw fixation for type A thoracolumbar fractures without neurological deficit
    Zheng, Zhangan
    Zhang, Li
    Zhu, Yu
    Chen, Jun
    Zhang, Xiaohai
    Xia, Taibao
    Wu, Tianliang
    Quan, Liangzhong
    Zhao, Guangchao
    Ji, Xuelei
    Gui, Zhaoliu
    Xue, Shuangtao
    Yin, Zongsheng
    JOURNAL OF ROBOTIC SURGERY, 2023, 17 (01) : 233 - 241
  • [50] Percutaneous cortical bone trajectory screw fixation versus traditional open pedicle screw fixation for type A thoracolumbar fractures without neurological deficit
    Zhangan Zheng
    Li Zhang
    Yu Zhu
    Jun Chen
    Xiaohai Zhang
    Taibao Xia
    Tianliang Wu
    Liangzhong Quan
    Guangchao Zhao
    Xuelei Ji
    Zhaoliu Gui
    Shuangtao Xue
    Zongsheng Yin
    Journal of Robotic Surgery, 2023, 17 : 233 - 241