Comparison of reendothelialization and neointimal formation with stents coated with antibodies against endoglin and CD34 in a porcine model

被引:4
|
作者
Cui, Song [1 ]
Song, Xian-Tao [1 ]
Ding, Chao [2 ]
Meng, Li-Jun [3 ]
Lv, Shu-Zheng [1 ]
Li, Kefeng [4 ,5 ]
机构
[1] Capital Med Univ, Anzhen Hosp, Dept Cardiol, Key Lab Remodeling Related Cardiovasc Dis, Beijing 100029, Peoples R China
[2] Huimin Peoples Hosp, Dept Cardiol, Binzhou, Peoples R China
[3] Binzhou Cent Hosp, Dept Cardiol, Binzhou, Peoples R China
[4] Univ Calif San Diego, Sch Med, San Diego, CA 92103 USA
[5] Tianjin SunnyPeak Biotech Co Ltd, Tianjin, Peoples R China
来源
DRUG DESIGN DEVELOPMENT AND THERAPY | 2015年 / 9卷
基金
中国博士后科学基金; 国家杰出青年科学基金; 美国国家科学基金会;
关键词
endothelialization; restenosis; anti-CD34; SIROLIMUS-ELUTING STENTS; GROWTH-FACTOR-BETA; RE-ENDOTHELIALIZATION; CORONARY; RESTENOSIS; RAPAMYCIN; PATHWAYS; INJURY; BLOOD; CELLS;
D O I
10.2147/DDDT.S81257
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Anti-CD34 coated stents are the only commercialized antibody-coated stents currently used for coronary artery diseases with various limitations. Endoglin plays important roles in the proliferation of endothelial cells and vascular remodeling and could be an ideal target surface molecule. The objective of this study was to investigate the efficacy of stents coated with anti-endoglin antibodies (ENDs) in terms of endothelial recovery and the reduction of neointimal formation. The performance of ENDs was evaluated by comparing with stents coated with anti-CD34 antibodies (CD34s), sirolimus-eluting stents (SESs), and bare metal stents (BMSs). Stents were randomly assigned and placed in the coronary arteries of juvenile pigs. Histomorphometric analysis and scanning electron microscopy were performed after stent implantation. Our results showed at 14 days after stent implantation, the neointima area and percent area stenosis in ENDs and CD34s were remarkably decreased compared with those in BMSs and SESs (P < 0.05). Moreover, the percentage of reendothelialization was significantly higher in ENDs and CD34s than that in SESs or BMSs at both 7 and 14 days (P < 0.05). There was no difference in the neointima area, percent area stenosis, and percentage of reendothelialization in ENDs compared with CD34s. The artery injury and the inflammation scores were similar in all groups at both 7 and 14 days. Our results demonstrate that the performance of ENDs is similar to the commercial CD34s, without the disadvantages of CD34s, and both are better than SESs and BMSs. ENDs potentially offer an alternative approach to reduce restenotic process and enhance reendothelialization after stent implantation.
引用
收藏
页码:2249 / 2256
页数:8
相关论文
共 50 条
  • [31] The expression of CD34 positive cells in neointima of coronary in-stent restenosis model in porcine
    Soda, T
    Suzuki, H
    Sato, T
    Shoji, M
    Iso, Y
    Shibata, M
    Koba, S
    Geshi, E
    Katagiri, T
    JOURNAL OF MOLECULAR AND CELLULAR CARDIOLOGY, 2003, 35 (11) : A36 - A36
  • [32] Study of the expression of CD34 antigen on acute non lymphoblastic leukemia (ANLL) blast cells using monoclonal antibodies directed against the three domains of the CD34 molecule
    Casasnovas, RO
    Campos, L
    Bene, MC
    Falckenrodt, A
    Lecalvez, G
    Bernier, M
    Faure, G
    Solary, E
    BRITISH JOURNAL OF HAEMATOLOGY, 1996, 93 : 1288 - 1288
  • [33] STEM CELL COATED METALLIC CORONARY STENTS SHOW ACCELERATED STRUT COVERAGE WITHOUT EXCESSIVE NEOINTIMAL PROLIFERATION IN A PORCINE MODEL
    Raina, Tushar
    Arnold, Nadine
    Moore, Harry
    Aflatoonian, Behrouz
    Walsh, Jim
    Whitehouse, Sam
    Al-Lamee, Kadem
    Francis, Sheila
    Gunn, Julian
    Iqbal, Javaid
    HEART, 2014, 100 : A88 - A89
  • [34] Trapidil-coated drug-eluting stents reduce neointimal hyperplasia at 28 days in a porcine model of coronary restenosis
    Sachar, R
    Furst, JG
    Brodbeck, WG
    Anderson, JM
    Whitlow, PL
    Yadav, JS
    CIRCULATION, 2004, 110 (17) : 756 - 757
  • [35] Cytochalasin D polymer-coated stents reduce neointima formation in a porcine coronary model
    Salu, KJ
    Bosmans, JM
    Huang, Y
    Liu, X
    Li, S
    De Scheerder, IK
    Bult, H
    Vrints, CJ
    EUROPEAN HEART JOURNAL, 2003, 24 : 426 - 426
  • [36] Comparison between Basic and Inverse Dual Drug and Peptide-coated Stents in a Porcine Restenosis Model
    Jang, Eun-Jae
    Lee, So-Youn
    Bae, In-Ho
    Park, Dae Sung
    Jeong, Myung Ho
    Park, Jun-Kyu
    APPLIED CHEMISTRY FOR ENGINEERING, 2020, 31 (05): : 502 - 508
  • [37] Monoclonal antibodies against human CD34 antigens do not cross-react with ovine umbilical cord blood cells
    Bonelli, Piero
    Nicolussi, Paola
    Manetti, Roberto
    Antuofermo, Elisabetta
    Dattena, Maria
    ITALIAN JOURNAL OF ANIMAL SCIENCE, 2010, 9 (01) : 26 - 28
  • [38] Sustained inhibition of neointimal hyperplasia after implanting novel biodegradable polymer-coated emodin-eluting stents in the porcine coronary model.
    Ge, J
    Liu, X
    Wang, KQ
    Qian, J
    Wang, X
    Jia, J
    Zhao, Y
    AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (6A): : 151E - 152E
  • [39] Paclitaxel-coated balloon catheter: influence of balloon insufflation time and high doses on neointimal formation in the porcine coronary model
    Scheller, B.
    Speck, U.
    Abramjuk, C.
    Nickenig, G.
    Boehm, M.
    EUROPEAN HEART JOURNAL, 2005, 26 : 236 - 236
  • [40] Paclitaxel-coated Gianturco-Roubin® IIAl (GR®II) stents reduce neointimal hyperplasia in a porcine coronary in-stent restenosis model
    Hong, MK
    Kornowski, R
    Bramwell, O
    Ragheb, AO
    Leon, MB
    CORONARY ARTERY DISEASE, 2001, 12 (06) : 513 - 515