Study of the behavior of induction motors under stator faults

被引:0
|
作者
Villada Duque, Fernando [1 ]
Parra, Diego [1 ]
Ocampo, Guillermo [1 ]
机构
[1] Univ Antioquia, Dept Ingn Elect, GIMEL, Medellin, Colombia
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Results of a study of the behavior of induction motors under stator faults are presented in this paper. Laboratory controlled short-circuits are induced between stator turns of induction motors. Mechanical vibrations, axial leakage flux and stator current are sensed in these motors; signals are then identified and compared to find the main harmonic components showing larger amplitude variations.
引用
收藏
页码:76 / 94
页数:19
相关论文
共 50 条
  • [21] A simplified technique for detecting mechanical faults using stator current in small induction motors
    Obaid, RR
    Habetler, TG
    Gritter, DJ
    IAS 2000 - CONFERENCE RECORD OF THE 2000 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-5, 2000, : 479 - 483
  • [22] Stator Current and Motor Efficiency as Indicators for Different Types of Bearing Faults in Induction Motors
    Frosini, Lucia
    Bassi, Ezio
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (01) : 244 - 251
  • [23] Advanced Residual Optimal Mapping Approach for Precise Detection of Stator Faults in Induction Motors
    Allal, Abderrahim
    Lammouchi, Zakaria
    Khechekhouche, Abderrahmane
    Mohamed, Naoui
    Alqunun, Khalid
    Alghadhban, Amer
    Marouani, Ismail
    Guesmi, Tawfik
    IEEE ACCESS, 2024, 12 : 143515 - 143530
  • [24] Stator Faults Detection on Induction Motors Using Harmonic Sequence Current Components Analysis
    Mazzoletti, Manuel A.
    Donolo, Pablo D.
    Pezzani, Carlos M.
    Oliveira, Mario O.
    Bossio, Guillermo R.
    De Angelo, Cristian H.
    IEEE LATIN AMERICA TRANSACTIONS, 2021, 19 (05) : 726 - 734
  • [25] Detection of turn to turn faults in stator winding with axial magnetic flux in induction motors
    Toni, Krstevski
    Slobodan, Mircevski
    Aleksandar, Buckovski
    IEEE IEMDC 2007: PROCEEDINGS OF THE INTERNATIONAL ELECTRIC MACHINES AND DRIVES CONFERENCE, VOLS 1 AND 2, 2007, : 826 - +
  • [26] Advanced Diagnosis of Stator Faults in Large Induction Motors Based on Internal Flux Measurement
    Saad, Khalid
    Mirzaeva, Galina
    2016 52ND ANNUAL MEETING OF THE IEEE INDUSTRY APPLICATIONS SOCIETY (IAS), 2016,
  • [27] Predicting behavior of induction motors during service faults and interruptions
    Key, Thomas S.
    IEEE Industry Applications Magazine, 1995, 1 (01):
  • [28] Analytic Model for Induction Motors Under Localized Bearing Faults
    Ojaghi, Mansour
    Sabouri, Mahdi
    Faiz, Jawad
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2018, 33 (02) : 617 - 626
  • [29] An accurate model of squirrel cage induction machines under stator faults
    Devanneaux, V
    Dagues, B
    Faucher, J
    Barakat, G
    MATHEMATICS AND COMPUTERS IN SIMULATION, 2003, 63 (3-5) : 377 - 391
  • [30] The Effect of Stator Inter-Turn Short Circuit Faults on Electromagnetic Performances of Induction Motors
    Chen, Peng
    Xie, Ying
    Hu, Shengming
    2019 22ND INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2019), 2019, : 622 - 626