Signal Amplification in a Microfluidic Paper-based Analytical Device (μ-PAD) by Confinement of the Fluidic Flow

被引:11
|
作者
Choi, Seoyeon [1 ]
Lee, Jung-Hyun [2 ]
Kwak, Bong Seop [3 ]
Kim, Young Woo [2 ]
Lee, Joon Sang [2 ]
Choi, Jong-Soon [4 ,5 ]
Jung, Hyo-Il [1 ,2 ]
机构
[1] Yonsei Univ, Nanomed Natl Core Res Ctr, Seoul 120749, South Korea
[2] Yonsei Univ, Sch Mech Engn, Seoul 120749, South Korea
[3] Korea Inst Machinery & Mat, Daegu, South Korea
[4] Korea Basic Sci Inst, Div Life Sci, Taejon, South Korea
[5] Chungnam Natl Univ, Grad Sch Analyt Sci & Technol, Daejeon, South Korea
关键词
Microfluidic paper-based analytical devices; Wax printing; Colorimetric; Salivary cortisol; ENHANCED SENSITIVITY; BIOCHIP TECHNOLOGY; DIAGNOSTIC DEVICES; NETWORK FORMAT; BIOMARKERS; STRIP;
D O I
10.1007/s13206-015-9204-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This is a one-step POC biosensor that guarantees rapid assay times, low-cost analysis, simple handling, stability, and is easy to mass product. However, it has several drawbacks such as limited sample volume and relatively low sensitivity. To overcome these disadvantages, we have designed and fabricated the mu-PAD to confine fluid flow by creating a hydrophobic channel in the paper to improve the sensitivity. The channel pattern was drawn by a computer-aided design program and directly printed by a commercially available wax printer which generates the hydrophobic channel pattern. While maintaining a constant sample, absorption, and conjugation pad, the width of the detection pad was reduced from 5 mm to 2 mm at intervals of 1 mm The intensity of bands from the single- and double-orifice patterns increased identically compared with the device with no orifice. The relative intensity of the signal bands increased from 141 to 158. Also, numerical simulation was performed to validate the experimental result by using lattice Boltzmann method. We observed that the sensitivity was enhanced at a specific detection pad width (3 mm) Therefore, our simple structural change of the channel led to improve the colorimetric intensity. Cortisol, which is a known stress biomarker, was used to validation the device, an enhanced signal was obtained indicating that our device can be used for the detection psychological stress in humans.
引用
收藏
页码:116 / 123
页数:8
相关论文
共 50 条
  • [41] Application of Paper-Based Microfluidic Analytical Devices (μPAD) in Forensic and Clinical Toxicology: A Review
    Musile, Giacomo
    Grazioli, Cristian
    Fornasaro, Stefano
    Dossi, Nicolo
    De Palo, Elio Franco
    Tagliaro, Franco
    Bortolotti, Federica
    BIOSENSORS-BASEL, 2023, 13 (07):
  • [42] Hybrid paper-based microfluidics: combination of paper-based analytical device (µPAD) and digital microfluidics (DMF) on a single substrate
    Arash Abadian
    Samira Sepehri Manesh
    Shahin Jafarabadi Ashtiani
    Microfluidics and Nanofluidics, 2017, 21
  • [43] Hybrid paper-based microfluidics: combination of paper-based analytical device (μPAD) and digital microfluidics (DMF) on a single substrate
    Abadian, Arash
    Manesh, Samira Sepehri
    Ashtiani, Shahin Jafarabadi
    MICROFLUIDICS AND NANOFLUIDICS, 2017, 21 (04)
  • [44] Fabrication, Flow Control, and Applications of Microfluidic Paper-Based Analytical Devices
    Lim, Hosub
    Jafry, Ali Turab
    Lee, Jinkee
    MOLECULES, 2019, 24 (16):
  • [45] FLOW CHARACTERIZATION OF MICROFLUIDIC PAPER-BASED ANALYTICAL DEVICES WITH HOLLOW CHANNELS
    Zhang, Haipeng
    Barmore, Danielle
    Ryu, Sangjin
    PROCEEDINGS OF THE ASME/JSME/KSME JOINT FLUIDS ENGINEERING CONFERENCE, 2019, VOL 4, 2019,
  • [46] Development of a microfluidic paper-based analytical device for magnesium determination in saliva samples
    Aguiar, Juliana I. S.
    Silva, Mafalda T. S.
    Ferreira, Helena A. G.
    Pinto, Elisabete C. B.
    Vasconcelos, Marta W.
    Rangel, Antonio O. S. S.
    Mesquita, Raquel B. R.
    TALANTA OPEN, 2022, 6
  • [47] New microfluidic paper-based analytical device for iron determination in urine samples
    Francisca T. S. M. Ferreira
    Karina A. Catalão
    Raquel B. R. Mesquita
    António O. S. S. Rangel
    Analytical and Bioanalytical Chemistry, 2021, 413 : 7463 - 7472
  • [48] Colorimetric determination of acidity constant using a paper-based microfluidic analytical device
    Taghizadeh-Behbahani, Maryam
    Hemmateenejad, Bahram
    Shamsipur, Mojtaba
    CHEMICAL PAPERS, 2018, 72 (05) : 1239 - 1247
  • [49] Optimization of a paper-based fluidic device for nitrogen detection
    Luthardt, Jackie
    DeShano, Emily
    Cissell, Kyle
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 251
  • [50] New microfluidic paper-based analytical device for iron determination in urine samples
    Ferreira, Francisca T. S. M.
    Catalao, Karina A.
    Mesquita, Raquel B. R.
    Rangel, Antonio O. S. S.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (30) : 7463 - 7472