The AX-PET demonstrator-Design, construction and characterization

被引:32
|
作者
Beltrame, P. [2 ]
Bolle, E. [7 ]
Braem, A. [2 ]
Casella, C. [1 ]
Chesi, E. [5 ]
Clinthorne, N. [6 ]
De Leo, R. [4 ]
Dissertori, G. [1 ]
Djambazov, L. [1 ]
Fanti, V. [2 ]
Heller, M. [2 ]
Joram, C. [2 ]
Kagan, H. [5 ]
Lustermann, W. [1 ]
Meddi, F. [8 ]
Nappi, E. [4 ]
Nessi-Tedaldi, F. [1 ]
Oliver, J. F. [3 ]
Pauss, F. [1 ]
Rafecas, M. [3 ]
Renker, D. [1 ]
Rudge, A. [5 ]
Schinzel, D. [1 ]
Schneider, T. [2 ]
Seguinot, J. [5 ]
Solevi, P. [3 ]
Stapnes, S. [7 ]
Weilhammer, P. [5 ]
机构
[1] ETH, Inst Particle Phys, CH-8093 Zurich, Switzerland
[2] CERN, PH Dept, CH-1211 Geneva, Switzerland
[3] Univ Valencia, CSIC, IFIC, E-46071 Valencia, Spain
[4] Ist Nazl Fis Nucl, Sez Bari, I-70122 Bari, Italy
[5] Ohio State Univ, Columbus, OH 43210 USA
[6] Univ Michigan, Ann Arbor, MI 48109 USA
[7] Univ Oslo, NO-0317 Oslo, Norway
[8] Univ Roma La Sapienza, I-00185 Rome, Italy
关键词
PET; Axial geometry; Geiger-mode Avalanche Photo Diodes (G-APD); SiPM; BRAIN; DETECTOR; SCANNER;
D O I
10.1016/j.nima.2011.06.059
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Axial PET is a novel geometrical concept for Positron Emission Tomography (PET), based on layers of long scintillating crystals axially aligned with the bore axis. The axial coordinate is obtained from arrays of wavelength shifting (WLS) plastic strips placed orthogonally to the crystals. This article describes the design, construction and performance evaluation of a demonstrator set-up which consists of two identical detector modules, used in coincidence. Each module comprises 48 LYSO crystals of 100 mm length and 156 WLS strips. Crystals and strips are readout by Geiger-mode Avalanche Photo Diodes (G-APDs). The signals from the two modules are processed by fully analog front-end electronics and recorded in coincidence by a VME-based data acquisition system. Measurements with point-like Na-22 sources, with the modules used both individually and in coincidence mode, allowed for a complete performance evaluation up to the focal plane reconstruction of point sources. The results obtained are in good agreement with expectations and proved the set-up to be ready for the next evaluation phase with PET phantoms filled with radiotracers. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:546 / 559
页数:14
相关论文
共 50 条
  • [21] Characterization of the demonstrator of the fast silicon monolithic ASIC for the TT-PET project
    Paolozzi, L.
    Bandi, Y.
    Cardarelli, R.
    Debieux, S.
    Favre, Y.
    Ferrere, D.
    Forshaw, D.
    Hayakawa, D.
    Iacobucci, G.
    Kaynak, M.
    Miucci, A.
    Nessi, M.
    Ripiccini, E.
    Ruecker, H.
    Valerio, P.
    Weber, M.
    JOURNAL OF INSTRUMENTATION, 2019, 14 (02)
  • [22] Characterization and design of digital pointing subsytem for optical communication demonstrator
    Racho, C
    Portillo, A
    FREE-SPACE LASER COMMUNICATION TECHNOLOGIES XI, 1999, 3615 : 250 - 261
  • [23] Construction and tests of an in-beam PET-like demonstrator for hadrontherapy beam ballistic control
    Montarou, G.
    Bony, M.
    Busato, E.
    Chadelas, R.
    Donnarieix, D.
    Force, P.
    Guicheney, C.
    Insa, C.
    Lambert, D.
    Lestand, L.
    Magne, M.
    Martin, F.
    Millardet, C.
    Nivoix, M.
    Podlyski, F.
    Rozes, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 845 : 673 - 678
  • [24] Design, construction, and testing of an anthropomorphic oncology phantom for PET/CT scanner characterization.
    Sunderland, John
    Muzic, Raymond
    Lodge, Martin
    Nye, Jonathon
    Zimmermann, Leonard
    Burrell, Lance
    Czachowski, Michael
    Wojtylak, Patrick
    Christian, Paul
    Bender, Benjamin
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [25] DESIGN AND CONSTRUCTION OF AN ACTIVE ALIGNMENT DEMONSTRATOR FOR A FREE-SPACE OPTICAL INTERCONNECT
    BOISSET, GC
    ROBERTSON, F
    HINTON, HS
    IEEE PHOTONICS TECHNOLOGY LETTERS, 1995, 7 (06) : 676 - 678
  • [26] Design and construction of Xenoscope - a full-scale vertical demonstrator for the DARWIN observatory
    Baudis, L.
    Biondi, Y.
    Galloway, M.
    Girard, F.
    Manfredini, A.
    McFadden, N.
    Peres, R.
    Sanchez-Lucas, P.
    Thieme, K.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (08):
  • [27] Construction and tests of demonstrator modules for a 3-D axial PET system for brain or small animal imaging
    Beltrame, P.
    Bolle, E.
    Braem, A.
    Casella, C.
    Chesi, E.
    Clinthorne, N.
    Cochran, E.
    De Leo, R.
    Dissertori, G.
    Djambazov, G.
    Fanti, V.
    Honscheid, K.
    Huh, S.
    Johnson, I.
    Joram, C.
    Kagan, H.
    Lustermann, W.
    Meddi, F.
    Nappi, E.
    Nessi-Tedaldi, F.
    Oliver, J. F.
    Pauss, P.
    Rafecas, M.
    Renker, D.
    Rudge, A.
    Schinzel, D.
    Schneider, T.
    Seguinot, J.
    Smith, S.
    Solevi, P.
    Stapnes, S.
    Weilhammer, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 636 : S226 - S230
  • [28] Monolithic Multi-Element HPGe Detector Equipped With CMOS Preamplifiers: Construction and Characterization of a Demonstrator
    Tartoni, Nicola
    Crook, R.
    Krings, T.
    Protic, D.
    Ross, C.
    Bombelli, L.
    Alberti, R.
    Frizzi, T.
    Astromskas, V.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (01) : 387 - 394
  • [29] Design considerations and construction of a small animal PET prototype
    Tzanakos, G.
    Nikolaou, M.
    Drakoulakos, D.
    Karamitros, D.
    Kontaxakis, G.
    Logaras, E.
    Panayiotakis, G.
    Pavlopoulos, S.
    Skiadas, M.
    Spyrou, G.
    Thireou, T.
    Vamvakas, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (02): : 235 - 239
  • [30] Construction and First Tests of an in-beam PET Demonstrator Dedicated to the Ballistic Control of Hadrontherapy Treatments With 65 MeV Protons
    Binet, S.
    Bongrand, A.
    Busato, E.
    Force, P.
    Guicheney, C.
    Insa, C.
    Lambert, D.
    Magne, M.
    Martin, F.
    Perrin, H.
    Podlyski, F.
    Rozes, A.
    Montarou, G.
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2018, 2 (01) : 51 - 60