Reducing post-extubation failure rates in very preterm infants: is BiPAP better than CPAP?

被引:6
|
作者
Capasso, Letizia [1 ]
Borrelli, Angela Carla [1 ]
Cerullo, Julia [1 ]
Caiazzo, Maria Angela [1 ]
Coppola, Clara [1 ]
Palma, Marta [1 ]
Raimondi, Francesco [1 ]
机构
[1] Univ Federico II, Dept Translat Med Sci, Div Neonatol, Via Pansini 5, I-80131 Naples, Italy
来源
关键词
BiPAP; CPAP; preterm neonates; RDS; non-invasive respiratory support; POSITIVE AIRWAY PRESSURE; MANAGEMENT;
D O I
10.1080/14767058.2020.1749256
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Background and Aim: Continuous positive airway pressure (CPAP) is currently used in neonates after mechanical ventilation though it may occasionally be associated with air leaks syndromes or it may fail to support the baby. The pressure difference offered by bilevel continuous positive distending pressure (BiPAP) respect to CPAP may be an advantage to the spontaneously breathing patient. In this study, we compared the efficacy of CPAP and BiPAP in the firstweek post-extubation in a series of very preterm infants. Methods: Inborn neonates less than 30 weeks of gestational age who were intubated shortly after birth from January 2011 to December 2017 were enrolled in a retrospective study. The attending clinician assessed the patients for non-invasive respiratory support readiness and allocated them to CPAP (PEEP 4-6 cmH(2)O) or BiPAP (PEEP 4-5 cmH(2)O, rate 10-40; Thigh 0.7-1.2; upper-pressure level 8-10 cmH(2)O). Both techniques were compared for preventing extubation failure within 7 days from extubation as defined per local protocol (primary outcome). Secondary outcomes were: definitive failure of extubation, pneumothorax during non-invasive respiratory support, periventricular leukomalacia, bronchopulmonary dysplasia, sepsis, patent ductus arteriosus and retinopathy of prematurity at discharge. Results: We enrolled 134 neonates; the CPAP group included 89 babies while 45 received BiPAP. Patients did not differ for their general characteristics (EG, antenatal steroids, incidence of SGA, maternal hypertension, surfactant replacement therapy). Short term extubation failure was significantly higher in the former group (23/89 in CPAP vs 5/45 in BiPAP; p = .005). No infant developed air leak syndrome. Secondary outcomes were comparable between groups. Multivariate analysis showed that on the whole population the extubation failure was correlated to the insurgence of late-onset sepsis. Conclusion: BiPAP safely reduced early extubation failure compared to CPAP in our cohort of very preterm neonates within 7 days from extubation.
引用
收藏
页码:1272 / 1277
页数:6
相关论文
共 44 条
  • [1] Post-extubation respiratory support for preterm infants
    Burki, Talha Khan
    LANCET RESPIRATORY MEDICINE, 2013, 1 (09): : 678 - 678
  • [2] Preterm VLBW infants: post-extubation respiratory support
    Maureen M Gilmore
    Journal of Perinatology, 2006, 26 : 449 - 451
  • [3] Preterm VLBW infants: post-extubation respiratory support
    Gilmore, Maureen M.
    JOURNAL OF PERINATOLOGY, 2006, 26 (08) : 449 - 451
  • [4] EFFICACY OF THEOPHYLLINE FOR PREVENTION OF POST-EXTUBATION RESPIRATORY-FAILURE IN INFANTS LESS THAN 1250 GRAMS
    VISCARDI, RM
    FAIX, RG
    GRASELA, TH
    NICKS, JJ
    PEDIATRIC RESEARCH, 1985, 19 (04) : A369 - A369
  • [5] EFFICACY OF THEOPHYLLINE FOR PREVENTION OF POST-EXTUBATION RESPIRATORY-FAILURE IN VERY LOW BIRTH-WEIGHT INFANTS
    VISCARDI, RM
    FAIX, RG
    NICKS, JJ
    GRASELA, TH
    JOURNAL OF PEDIATRICS, 1985, 107 (03): : 469 - 472
  • [6] Preventing extubation failure in preterm infants: nasal CPAP remains the standard of care
    Sherlock, Laurie G.
    Wright, Clyde J.
    ACTA PAEDIATRICA, 2017, 106 (08) : 1364 - 1364
  • [7] Extubation failure due to post-extubation stridor is better correlated with neurologic impairment than with upper airway lesions in critically ill pediatric patients
    Harel, Y
    Vardi, A
    Quigley, R
    Brink, LW
    Manning, SC
    Carmody, TJ
    Levin, DL
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 1997, 39 (02) : 147 - 158
  • [8] COMPARISON OF CARDIORESPIRATORY BEHAVIOR IN EXTREME PRETERM INFANTS RECEIVING NASAL CPAP AND HIGH FLOW NASAL CANNULA DURING THE IMMEDIATE POST-EXTUBATION PERIOD
    Kanbar, L.
    Shalish, W.
    Brown, K.
    Kearney, R.
    Sant'Anna, G.
    EUROPEAN JOURNAL OF PEDIATRICS, 2016, 175 (11) : 1594 - 1594
  • [9] Association between pulmonary hemorrhage and CPAP failure in very preterm infants
    Wang, Li
    Zhao, Li-li
    Xu, Jia-ju
    Yu, Yong-hui
    Li, Zhong-liang
    Zhang, Feng-juan
    Wen, Hui-min
    Wu, Hai-huan
    Deng, Li-ping
    Yang, Hui-yu
    Li, Li
    Ding, Lan-lan
    Wang, Xiao-kang
    Zhang, Cheng-yuan
    Wang, Hui
    FRONTIERS IN PEDIATRICS, 2022, 10
  • [10] EFFICACY OF THEOPHYLLINE FOR PREVENTION OF POST-EXTUBATION RESPIRATORY-FAILURE IN VERY LOW-BIRTH-WEIGHT INFANTS (LESS-THAN-OR-EQUAL-TO 1250 GM)
    VISCARDI, RM
    FAIX, RG
    GRASELA, TH
    NICKS, JJ
    CLINICAL RESEARCH, 1984, 32 (04): : A808 - A808