A hydrogen peroxide sensor for exhaled breath measurement

被引:35
|
作者
Anh, DTV [1 ]
Olthuis, W [1 ]
Bergveld, P [1 ]
机构
[1] Univ Twente, MESA Res Inst, Lab Chip Grp, NL-7500 AE Enschede, Netherlands
来源
关键词
hydrogen peroxide sensor; (MOSFET)-M-E; exhaled breath; lung diseases;
D O I
10.1016/j.snb.2005.03.107
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An increase in hydrogen peroxide concentration in exhaled breath (EB) of patients, who suffer from some diseases related to the lung, function, has been observed and considered as a reliable indicator of lung diseases. In the EB of these patients, hydrogen peroxide is present in the vapour phase together with water, thus one of the approaches of monitoring hydrogen peroxide in the EB is to condense it and then to perform the hydrogen peroxide measurement in the condensate. Earlier, a hydrogen peroxide sensor based on an electrolyte metal oxide semiconductor field-effect transistor ((MOSFET)-M-E) has been investigated. The sensor shows the possibility to measure hydrogen peroxide at a concentration of micro-molar level. Due to its miniaturizability, the sensor is able to detect hydrogen peroxide in a small volume and is thus especially suitable for monitoring of hydrogen peroxide in the EB. In this paper, a simple set-up for condensation of hydrogen peroxide in the EB is introduced. The set-up consists of a cooling tube using a Peltier element for condensation of the exhaled breath air and the (MOSFET)-M-E-based hydrogen peroxide sensor. Using this cooling tube, primary results on the collection and measurement of hydrogen peroxide in artificial EB are given. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:494 / 499
页数:6
相关论文
共 50 条
  • [21] Quantitative analysis of 8-isoprostane and hydrogen peroxide in exhaled breath condensate
    Van Hoydonck, PGA
    Wuyts, WA
    Vanaudenaerde, BM
    Schouten, EG
    Dupont, LJ
    Temme, EHM
    EUROPEAN RESPIRATORY JOURNAL, 2004, 23 (02) : 189 - 192
  • [22] Collection and analysis of exhaled breath condensate hydrogen peroxide in conscious healthy dogs
    Wyse, CA
    Hammond, J
    Arteaga, A
    Cumming, D
    Cooper, JM
    McEwan, JD
    Yam, PS
    VETERINARY RECORD, 2004, 155 (23) : 744 - 746
  • [23] Apocynin decreases hydrogen peroxide and nirtate concentrations in exhaled breath in healthy subjects
    Stefanska, J.
    Sokolowska, M.
    Sarniak, A.
    Wlodarczyk, A.
    Doniec, Z.
    Nowak, D.
    Pawliczak, R.
    PULMONARY PHARMACOLOGY & THERAPEUTICS, 2010, 23 (01) : 48 - 54
  • [24] Exhaled breath condensate pH and hydrogen peroxide as non-invasive markers for asthma
    Al-Obaidy, Amina H.
    Al-Samarai, Abdul-Ghani M.
    SAUDI MEDICAL JOURNAL, 2007, 28 (12) : 1860 - 1863
  • [25] Exhaled breath condensate hydrogen peroxide and pH for the assessment of lower airway inflammation in the horse
    Duz, M.
    Whittaker, A. G.
    Love, S.
    Parkin, T. D. H.
    Hughes, K. J.
    RESEARCH IN VETERINARY SCIENCE, 2009, 87 (02) : 307 - 312
  • [26] Determination of hydrogen peroxide in exhaled breath condensate by flow injection analysis with fluorescence detection
    Svensson, S
    Olin, AC
    Lärstad, M
    Ljungkvist, G
    Torén, K
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 809 (02): : 199 - 203
  • [27] Fractionated Exhaled Breath Condensate Collection Shows High Hydrogen Peroxide Release in the Airways
    Moeller, Winfried
    Heimbeck, Irene
    Weber, Norbert
    Saba, Guelnaz Khadem
    Koerner, Benjamin
    Neiswirth, Margot
    Kohlhaeufl, Martin
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2010, 23 (03) : 129 - 135
  • [28] Increased amounts of hydrogen peroxide in the exhaled breath of ozone-exposed human subjects
    Madden, MC
    Hanley, N
    Harder, S
    Velez, G
    Raymer, JH
    INHALATION TOXICOLOGY, 1997, 9 (04) : 317 - 330
  • [29] BEDSIDE MEASUREMENT OF EXHALED BREATH CONDENSATE HYDROGEN PEROXIDE DIFFERENTIATES LUNG CANCER AND INTERSTITIAL LUNG DISEASE FROM HEALTHY CONTROLS
    Lodge, D. M.
    Neville, D.
    Brown, T.
    Rupani, H.
    Babu, K. S.
    Bishop, L.
    Heiden, E.
    Gates, J.
    Longstaff, J.
    Winter, J.
    Begum, S.
    Chauhan, A. J.
    THORAX, 2019, 74 : A133 - A133
  • [30] Investigation of a Plasmonic Optical Sensor for Acetone Detection in Exhaled Breath and Exhaled Breath Condensate
    Fernandes, Gabriel Bruno Monteiro
    Nascimento, Helder
    Cruz, Rossana Moreno Santa
    Marques, Jefferson Luiz Brum
    Moreira, Cleumar da Silva
    PLASMONICS, 2024, 19 (05) : 2527 - 2535