Whole body [18F]fluorodeoxyglucose positron emission tomography imaging for the diagnosis of pacemaker or implantable cardioverter defibrillator infection: a preliminary prospective study

被引:94
|
作者
Bensimhon, L. [1 ]
Lavergne, T. [2 ]
Hugonnet, F. [1 ]
Mainardi, J. -L. [3 ]
Latremouille, C. [4 ]
Maunoury, C. [1 ]
Lepillier, A. [2 ]
Le Heuzey, J. -Y. [2 ]
Faraggi, M. [1 ]
机构
[1] Paris Descartes Univ, Hop Europeen Georges Pompidou Paris, Dept Nucl Med, Paris, France
[2] Paris Descartes Univ, Hop Europeen Georges Pompidou Paris, Dept Cardiol, Paris, France
[3] Paris Descartes Univ, Hop Europeen Georges Pompidou Paris, Dept Microbiol, Paris, France
[4] Paris Descartes Univ, Hop Europeen Georges Pompidou Paris, Dept Cardiovasc Surg, Paris, France
关键词
F-18-FDG; infection; pacemaker; PET-CT; FDG-PET;
D O I
10.1111/j.1469-0691.2010.03312.x
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
We studied the potential use of [F-18]fluorodeoxyglucose (F-18-FDG) whole body positron emission tomography (PET)-computed tomography for the diagnosis of device infection and extension of infection. Twenty-one patients with suspected device infection were prospectively included and compared with 14 controls free of infection. F-18-FDG uptake on the box and on the leads was visually and quantitatively interpreted (using the maximal standard uptake value). The final diagnosis was obtained either from bacteriological data after device culture (n = 11) or by a 6-month follow-up according to modified Duke's criteria (n = 10). Ten patients finally showed infection on bacteriological study (n = 8) or during follow-up (n = 2). Sensitivity, specificity, positive predictive value and negative predictive value were, respectively, 80%, 100%, 100% and 84.6% on patient-based analysis (presence or absence of infection). They were 100%, 100%, 100% and 100% for boxes, but only 60%, 100%, 100% and 73% for leads. Quantitative analysis could be useful for boxes but not for leads, for which the presence of a mild hot spot was the best criterion of infection. The four false negatives on leads received antibiotics for longer than the six true positives (20 +/- 7.2 vs. 3.2 +/- 2.3 days, p < 0.01). Although the study was not designed for this purpose, management could have been modified by PET results in six of 21 patients. F-18-FDG PET imaging may be useful for the diagnosis of device infection, and could impact on clinical management. Interpretation of negative cases should be performed with caution if patients have received antibiotics.
引用
收藏
页码:836 / 844
页数:9
相关论文
共 50 条
  • [41] Pacemaker-related infection detected by 18F-fluorodeoxyglucose positron emission tomography-computed tomography
    Peixoto, Giselle de Lima
    Siciliano, Rinaldo Focaccia
    Camargo, Raphael Abegao
    Bueno, Fabiana Lucas
    Soares Junior, Jose
    Costa, Roberto
    Mara, Tania
    Strabelli, Varejao
    Martinelli Filho, Martino
    [J]. INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2014, 19 : 87 - 90
  • [42] Diagnosis of prostatitis by 18-F-fluorodeoxyglucose positron emission tomography
    Thien Anh Ho
    Lonneux, Max
    Devuyst, Olivier
    [J]. CLINICAL KIDNEY JOURNAL, 2009, 2 (01): : 87 - 88
  • [43] The role of 18F-fluorodeoxyglucose positron emission tomography/computed tomography whole body imaging in the evaluation of focal thyroid incidentaloma
    G. Zhai
    M. Zhang
    H. Xu
    C. Zhu
    B. Li
    [J]. Journal of Endocrinological Investigation, 2010, 33 : 151 - 155
  • [44] The role of 18F-fluorodeoxyglucose positron emission tomography/computed tomography whole body imaging in the evaluation of focal thyroid incidentaloma
    Zhai, G.
    Zhang, M.
    Xu, H.
    Zhu, C.
    Li, B.
    [J]. JOURNAL OF ENDOCRINOLOGICAL INVESTIGATION, 2010, 33 (03) : 151 - 155
  • [45] Is F 18 Fluorodeoxyglucose Positron Emission Tomography Too Sensitive for the Diagnosis of Vascular Endograft Infection?
    Zimmerman, Pamela M.
    Cherr, Gregory S.
    Angelos, George C.
    Gona, Jayakumari
    Dosluoglu, Hasan H.
    [J]. VASCULAR, 2008, 16 (06) : 346 - 349
  • [46] The use of positron emission tomography with (18) F-Fluorodeoxyglucose for the diagnosis of vascular graft infection
    Lauwers, Patrick
    Van den Broeck, Sylvie
    Carp, Laurens
    Hendriks, Jeroen
    Van Schil, Paul
    Blockx, Pierre
    [J]. ANGIOLOGY, 2007, 58 (06) : 717 - 724
  • [47] Controlled prospective study of positron emission tomography using the glucose analogue [18F]fluorodeoxyglucose in the evaluation of pulmonary nodules
    Präuer, HW
    Weber, WA
    Römer, W
    Treumann, T
    Ziegler, SI
    Schwaiger, M
    [J]. BRITISH JOURNAL OF SURGERY, 1998, 85 (11) : 1506 - 1511
  • [48] [18F]Fluorodeoxyglucose Positron Emission Tomography for Lung Antiinflammatory Response Evaluation
    Chen, Delphine L.
    Bedient, Timothy J.
    Kozlowski, James
    Rosenbluth, Daniel B.
    Isakow, Warren
    Ferkol, Thomas W.
    Thomas, Betsy
    Mintun, Mark A.
    Schuster, Daniel P.
    Walter, Michael J.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 180 (06) : 533 - 539
  • [49] [18F]-Fluorodeoxyglucose-Positron Emission Tomography in Patients With Active Myelopathy
    Flanagan, Eoin P.
    Hunt, Christopher H.
    Lowe, Val
    Mandrekar, Jay
    Pittock, Sean J.
    O'Neill, Brian Patrick
    Keegan, B. Mark
    [J]. MAYO CLINIC PROCEEDINGS, 2013, 88 (11) : 1204 - 1212
  • [50] Early clinical experience and impact of [18F]fluorodeoxyglucose positron emission tomography
    Uludag, ATA
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2006, 27 (04) : 405 - 405