Limits of mass transfer enhancement in lithium bromide-water absorbers by active techniques

被引:28
|
作者
Tsai, BB [1 ]
Perez-Blanco, H [1 ]
机构
[1] Penn State Univ, Dept Mech Engn, University Pk, PA 16802 USA
关键词
D O I
10.1016/S0017-9310(97)00287-1
中图分类号
O414.1 [热力学];
学科分类号
摘要
A model to predict the theoretical limits of mass transfer enhancement in a falling film absorber using LiBr aqueous solution has been developed and it provides a means of comparative absorber performance evaluation. During vapor absorption, the vapor-liquid interface becomes saturated immediately after it is exposed to vapor. Further absorption can only be sustained by mass diffusion and heat conduction into the fluid bulk, assuming a stationary interface. Due to the relatively small heat and mass diffusivities of LiBr aqueous solution, the mass absorption rates sustained by pure diffusion and conduction processes are small. To increase the mass absorption rates, mixing of the solution is favored. Therefore, every mass transfer enhancement technique, passive or active, consists of basically disturbing the film and causing mixing of the solution near the interface. The higher the mixing rate, the higher the mass absorption rate. To assess the effect of a mixed interface, a mathematical model is formulated. This model solves one-dimensional heat and mass differential equations coupled at the interface. An asymptote of the mass transfer rate as the mixing rate increases is derived. The model, which lakes into account all relevant parameters such as temperatures, pressures, concentrations, mass flow rates, and geometry, is an ideal tool for rating absorber performance. Results show that, under typical operating conditions found in commercial chillers, the theoretically possible maximum mass absorption rate is 0.049 kg m(2) . s(-1) and that, at a mechanically feasible mixing frequency of 1000 Hz, a mass absorption rate of 0.0256 kg m(2) . s(-1) is possible. The latter rate is about an order of magnitude larger than that found in commercial chillers. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
下载
收藏
页码:2409 / 2416
页数:8
相关论文
共 50 条
  • [21] Energy analysis of lithium bromide-water and lithium chloride-water based single effect vapour absorption refrigeration system: A comparison study
    Ahmad, Tausif
    Azhar, Md
    Sinha, M. K.
    Meraj, Md
    Mahbubul, Islam Mohammed
    Ahmad, Akbar
    CLEANER ENGINEERING AND TECHNOLOGY, 2022, 7
  • [22] Parametric Study of a Single Effect Lithium Bromide-Water Absorption Chiller Powered by a Renewable Heat Source
    Tawalbeh, Muhammad
    Salameh, Tareq
    Albawab, Mona
    Al-Othman, Amani
    Assad, Mamdouh El Haj
    Alami, Abdul H.
    JOURNAL OF SUSTAINABLE DEVELOPMENT OF ENERGY WATER AND ENVIRONMENT SYSTEMS-JSDEWES, 2020, 8 (03): : 464 - 475
  • [23] Optimization of a lithium bromide-water solar absorption cooling system with evacuated tube collectors using the genetic algorithm
    Iranmanesh, A.
    Mehrabian, M. A.
    ENERGY AND BUILDINGS, 2014, 85 : 427 - 435
  • [24] Performance analysis and optimization of new double effect lithium bromide-water absorption chiller with series and parallel flows
    Chahartaghi, Mahmood
    Golmohammadi, Hesam
    Shojaei, Arsalan Faghih
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 97 : 73 - 87
  • [25] Exergy analysis of single to triple effect lithium bromide-water vapour absorption cycles and optimization of the operating parameters
    Azhar, Md.
    Siddiqui, M. Altamush
    ENERGY CONVERSION AND MANAGEMENT, 2019, 180 : 1225 - 1246
  • [26] Surface tension of aqueous lithium bromide with heat/mass transfer enhancement additives: the effect of additive vapor transport
    Kulankara, S
    Herold, KE
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2002, 25 (03): : 383 - 389
  • [27] Experimental evaluation of a direct air-cooled lithium bromide-water absorption prototype for solar air conditioning
    Gonzalez-Gil, A.
    Izquierdo, M.
    Marcos, J. D.
    Palacios, E.
    APPLIED THERMAL ENGINEERING, 2011, 31 (16) : 3358 - 3368
  • [28] Influence of the Average Daily Outdoor Air Parameters on the Efficiency of Solar Lithium Bromide-Water Absorption Refrigeration Machine
    Malinina, O. S.
    Baranenko, A. V.
    Zaitsev, A. V.
    OIL AND GAS ENGINEERING (OGE-2018), 2018, 2007
  • [29] HEAT AND MASS-TRANSFER STUDIES ON WATER LITHIUM BROMIDE ABSORPTION HEAT-PUMP SYSTEMS
    EISA, MAR
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1991, 34 (03) : 891 - 894
  • [30] Experimental study about heat and mass transfer during absorption of water by an aqueous lithium bromide solution
    Francés, VMS
    Ojer, JMP
    THERMAL SCIENCES 2000, 2000, : 535 - +