An acetylcholinesterase/choline oxidase-based amperometric biosensor as a liquid chromatography detector for acetylcholine and choline determination in brain tissue homogenates

被引:67
|
作者
Guerrieri, A [1 ]
Palmisano, F [1 ]
机构
[1] Univ Bari, Dipartimento Chim, I-70126 Bari, Italy
关键词
D O I
10.1021/ac000852h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A liquid chromatography (LC) detector based on a fast response and sensitive bienzyme amperometric biosensor for acetylcholine (ACh) and choline (Ch) is described. The detector fabrication consisted of glutaraldehyde co-crosslinking of acetylcholinesterase and choline oxidase with bovine serum albumin on the Pt working electrode of a conventional thin-layer electrochemical flow cell. The influence of some experimental parameters (e,g,, enzyme loading, thickness of the bienzyme layer, flow rate) on the detector characteristics has been studied in order to optimize the analyte response while minimizing band-broadening and distortion. A mobile phase consisting of a phosphate buffer (I, 0.1 M; pH, 6.5) containing 5 mM sodium hexane sulfonate and 10 mM tetramethylammonium phosphate was found to give very satisfactory resolution and peak shape in ion-pair, reversed-phase LC, Linear responses were observed over at least four decades and absolute detection limits (at a signal-to-noise ratio of 3) were 12 and 27 fmol injected for Ch and ACh, respectively. After one month of intensive use in the LC system, the detector retained about 70% of its initial sensitivity. The potential of the described approach is demonstrated by the simultaneous determination of Ch and ACh in rat brain tissue homogenates.
引用
下载
收藏
页码:2875 / 2882
页数:8
相关论文
共 50 条
  • [1] Development of an acetylcholinesterase-choline oxidase based biosensor for acetylcholine determination
    Tunc, Ayse Tugce
    Koyuncu, Elif Aynaci
    Arslan, Fatma
    ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY, 2016, 44 (07) : 1659 - 1664
  • [2] Acetylcholinesterase - Choline Oxidase Biosensor for Pirimicarb Determination
    Sousa, S. C. A.
    Rebelo, M. J. F.
    PORTUGALIAE ELECTROCHIMICA ACTA, 2008, 26 (01) : 65 - 75
  • [3] Flow amperometric biosensor based on two enzymatic reactors (acetylcholinesterase-choline oxidase) for the detection of neurotransmitter acetylcholine
    Tvorynska, Sofiia
    Barek, Jiri
    Josypcuk, Bohdan
    PROCEEDINGS OF THE 15TH INTERNATIONAL STUDENTS CONFERENCE MODERN ANALYTICAL CHEMISTRY, 2019, : 61 - 66
  • [4] An amperometric biosensor for acetylcholine determination prepared from acetylcholinesterase-choline oxidase immobilized in polypyrrole-polyvinylsulpfonate film
    Aynaci, Elif
    Yasar, Ahmet
    Arslan, Fatma
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 202 : 1028 - 1036
  • [5] Construction of an acetylcholinesterase-choline oxidase biosensor for aldicarb determination
    Kök, FN
    Bozoglu, F
    Hasirci, V
    NOVEL PROCESSES AND CONTROL TECHNOLOGIES IN THE FOOD INDUSTRY, 2001, 338 : 49 - 62
  • [6] Construction of an acetylcholinesterase-choline oxidase biosensor for aldicarb determination
    Kok, FN
    Bozoglu, F
    Hasirci, V
    BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7): : 531 - 539
  • [7] EVALUATION OF THE USE OF FREE AND IMMOBILIZED ACETYLCHOLINESTERASE FOR PARAOXON DETECTION WITH AN AMPEROMETRIC CHOLINE OXIDASE BASED BIOSENSOR
    CREMISINI, C
    DISARIO, S
    MELA, J
    PILLOTON, R
    PALLESCHI, G
    ANALYTICA CHIMICA ACTA, 1995, 311 (03) : 273 - 280
  • [8] Ascorbic Acid Determination by an Amperometric Ascorbate Oxidase-based Biosensor
    Pisoschi, Aurelia-Magdalena
    Negulescu, Gheorghe-Petre
    Pisoschi, Aurel
    REVISTA DE CHIMIE, 2010, 61 (04): : 339 - 344
  • [9] An amperometric biosensor for choline determination prepared from choline oxidase immobilized in polypyrrole-polyvinylsulfonate film
    Ozdemir, Merve
    Arslan, Fatma
    Arslan, Halit
    ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2012, 40 (04): : 280 - 284
  • [10] Determination of binary pesticide mixtures by an acetylcholinesterase-choline oxidase biosensor
    Kok, FN
    Hasirci, V
    BIOSENSORS & BIOELECTRONICS, 2004, 19 (07): : 661 - 665