Experiences with packed capillary electrochromatography at ambient pressure

被引:103
|
作者
vandenBosch, SE [1 ]
Heemstra, S [1 ]
Kraak, JC [1 ]
Poppe, H [1 ]
机构
[1] UNIV AMSTERDAM,ANALYT CHEM LAB,AMSTERDAM INST MOL STUDIES,NL-1018 WV AMSTERDAM,NETHERLANDS
关键词
air bubbles; electrochromatography; capillary columns; packed capillary columns; packing retainers; frits; phenols; polynuclear aromatic hydrocarbons;
D O I
10.1016/S0021-9673(96)00612-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The practical execution of packed capillary electrochromatography is evaluated. The most serious problem is the generation of air bubbles in the system. This occurs especially in frits which were fabricated by glueing particles differing from the packing particles. No air bubbles were generated with frits which were prepared by locally sintering a narrow band of the reversed-phase packing by means of a heating filament, while flushing the column with water. In this way electrochromatography can be performed simply without pressurizing the buffer vials, providing the mobile phase is frequently degassed with helium. The performance under electrically driven conditions appears to be excellent and for 5 mu m reversed-phase particles reduced plate heights down to 1.8 were achieved. Compared to pressure driven conditions, 25-40% smaller plate heights were obtained under electrically driven conditions.
引用
收藏
页码:165 / 177
页数:13
相关论文
共 50 条
  • [21] Packed-column capillary electrochromatography and capillary electrochromatography-mass spectrometry using a lithocholic acid stationary phase
    Norton, Dean
    Shamsi, Shahab A.
    ELECTROPHORESIS, 2008, 29 (10) : 2004 - 2015
  • [22] A Novel Approach to Prepare a Glass-Fiber-Packed Capillary Column for Capillary Electrochromatography
    Shi, Zhi-Guo
    Wei, Fang
    Feng, Yu-Qi
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2008, 31 (20) : 3094 - 3104
  • [23] Enantiomer separation by CEC——Enantiomer separation by packed-capillary electrochromatography
    朱军
    邹汉法
    施维
    芮建中
    倪坚毅
    张玉奎
    Science in China(Series B), 1999, (05) : 511 - 519
  • [24] Kinetic performance evaluation and perspectives of contemporary packed column capillary electrochromatography
    De Smet, Seppe
    Lynen, Frederic
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1355 : 261 - 268
  • [25] Practical experiences and applications of capillary electrochromatography in the pharmaceutical industry
    Euerby, MR
    Johnson, CM
    Bartle, KD
    LC GC-MAGAZINE OF SEPARATION SCIENCE, 1998, 16 (04): : 386 - +
  • [26] Practical Experiences and Applications of Capillary Electrochromatography in the Pharmaceutical Industry
    Euerby, M. R.
    Johnson, C. M.
    Bartle, K. D.
    LG -GC, 16 (04):
  • [27] Light-scattering studies of packed stationary phases for capillary electrochromatography
    Owens, PK
    Johansson, J
    ANALYTICAL CHEMISTRY, 2000, 72 (04) : 740 - 746
  • [28] Photopolymerized sol-gel frits for packed columns in capillary electrochromatography
    Kato, M
    Dulay, MT
    Bennett, BD
    Quirino, JP
    Zare, RN
    JOURNAL OF CHROMATOGRAPHY A, 2001, 924 (1-2) : 187 - 195
  • [29] Magnetically immobilized frits for the preparation of packed columns used in capillary electrochromatography
    Wang, Hongling
    Cao, Jingjing
    Bi, Yanping
    Chen, Lei
    Wan, Qian-Hong
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (31) : 5882 - 5887
  • [30] Enantiomer separation by CEC - Enantiomer separation by packed-capillary electrochromatography
    Zhu, J
    Zou, HF
    Shi, W
    Rui, JZ
    Ni, JY
    Zhang, YK
    SCIENCE IN CHINA SERIES B-CHEMISTRY, 1999, 42 (05): : 511 - 519