Validity and reliability of a novel optoelectronic device to measure movement velocity, force and power during the back squat exercise

被引:16
|
作者
Laza-Cagigas, Roberto [1 ]
Goss-Sampson, Mark [1 ]
Larumbe-Zabala, Eneko [2 ]
Termkolli, Leke [1 ]
Naclerio, Fernando [1 ]
机构
[1] Univ Greenwich, Dept Life & Sport Sci, Sparrow Lane,Avery Hill, New Eltham SE9 2BT, England
[2] Texas Tech Univ HSC, Clin Res Inst, Lubbock, TX 79409 USA
关键词
Resistance training; 3-D motion captures systems; force plate; accelerometers; linear transducers; RES; 0-10; SCALE; CORRELATION-COEFFICIENT; STRENGTH; LOAD; PREDICTION;
D O I
10.1080/02640414.2018.1527673
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
This study analysed the validity and reliability of a new optoelectronic device (Velowin) for the measurement of vertical displacement and velocity as well as to estimate force and mechanical power. Eleven trained males with Mean (SD) age = 27.4 (4.8) years, completed an incremental squat exercise test with 5 different loads (<30-90% of their 1-repetition maximum) while displacement and vertical velocity of the barbell were simultaneously measured using an integrated 3D system (3D motion capture system + force platform) and Velowin. Substantial to almost perfect correlation (concordance correlation coefficient = 0.75-0.96), root mean square error as coefficient of variation +/- 90% confidence interval <= 10% and good to excellent intraclass correlation coefficient = 0.84-0.99 were determined for all the variables. Passing and Bablock regression methods revealed no differences for average velocity. However, significant but consistent bias were determined for average or peak force and power while systematic and not proportional bias was found for displacement. In conclusion, Velowin, in holds of some potential advantages over traditionally used accelerometer or linear transducers, represents a valid and reliable alternative to monitor vertical displacement and velocity as well as to estimate average force and mechanical power during the squat exercise.
引用
收藏
页码:795 / 802
页数:8
相关论文
共 50 条
  • [1] VALIDITY AND RELIABILITY OF THE PUSH WEARABLE DEVICE TO MEASURE MOVEMENT VELOCITY DURING THE BACK SQUAT EXERCISE
    Balsalobre-Fernandez, Carlos
    Kuzdub, Matt
    Poveda-Ortiz, Pedro
    del Campo-Vecino, Juan
    [J]. JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2016, 30 (07) : 1968 - 1974
  • [2] Reliability and concurrent validity of the Velowin optoelectronic system to measure movement velocity during the free-weight back squat
    Garcia-Ramos, Amador
    Perez-Castilla, Alejandro
    Martin, Fernando
    [J]. INTERNATIONAL JOURNAL OF SPORTS SCIENCE & COACHING, 2018, 13 (05) : 737 - 742
  • [3] Validity and reliability of an optoelectronic system to measure movement velocity during bench press and half squat in a Smith machine
    Muniz-Pardos, Borja
    Lozano-Berges, Gabriel
    Marin-Puyalto, Jorge
    Gonzalez-Aguero, Alex
    Vicente-Rodriguez, German
    Casajus, Jose A.
    Garatachea, Nuria
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART P-JOURNAL OF SPORTS ENGINEERING AND TECHNOLOGY, 2020, 234 (01) : 88 - 97
  • [4] VALIDITY AND RELIABILITY OF A WEARABLE INERTIAL SENSOR TO MEASURE VELOCITY AND POWER IN THE BACK SQUAT AND BENCH PRESS
    Orange, Samuel T.
    Metcalfe, James W.
    Liefeith, Andreas
    Marshall, Phil
    Madden, Leigh A.
    Fewster, Connor R.
    Vince, Rebecca V.
    [J]. JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2019, 33 (09) : 2398 - 2408
  • [5] Validity and reliability of the WIMU® system to measure barbell velocity during the half-squat exercise
    Garcia-Pinillos, Felipe
    Latorre-Roman, Pedro A.
    Valdivieso-Ruano, Fernando
    Balsalobre-Fernandez, Carlos
    Parraga-Montilla, Juan A.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART P-JOURNAL OF SPORTS ENGINEERING AND TECHNOLOGY, 2019, 233 (03) : 408 - 415
  • [6] Validity of Various Methods for Determining Velocity, Force, and Power in the Back Squat
    Banyard, Harry G.
    Nosaka, Ken
    Sato, Kimitake
    Haff, G. Gregory
    [J]. INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2017, 12 (09) : 1170 - 1176
  • [7] Validity and Reliability of Inertial Measurement System for Linear Movement Velocity in Flywheel Squat Exercise
    Maroto-Izquierdo, Sergio
    Nosaka, Kazunori
    Alarcon-Gomez, Jesus
    Martin-Rivera, Fernando
    [J]. SENSORS, 2023, 23 (04)
  • [8] Force/velocity and power/velocity relationships in squat exercise
    Abderrehmane Rahmani
    Fabrice Viale
    Georges Dalleau
    Jean-René Lacour
    [J]. European Journal of Applied Physiology, 2001, 84 : 227 - 232
  • [9] Force/velocity and power/velocity relationships in squat exercise
    Rahmani, A
    Viale, F
    Dalleau, G
    Lacour, JR
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2001, 84 (03) : 227 - 232
  • [10] Reliability Of A Velocity Measuring Device During Four Intensities Of The Barbell Back Squat
    Tagesen, Emily C.
    Gant, Ryan W.
    Rivera, Jennifer
    Davis, Benjamin R.
    Pelka, Edward Z.
    Pinzone, Anthony G.
    Lebron, Modesto A.
    Jajtner, Adam R.
    [J]. MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2022, 54 (09) : 19 - 20