Validity and Reliability of Inertial Measurement System for Linear Movement Velocity in Flywheel Squat Exercise

被引:2
|
作者
Maroto-Izquierdo, Sergio [1 ]
Nosaka, Kazunori [2 ]
Alarcon-Gomez, Jesus [3 ]
Martin-Rivera, Fernando [3 ]
机构
[1] European Univ Miguel Cervantes, i HeALTH, Valladolid 47012, Spain
[2] Edith Cowan Univ, Ctr Human Performance, Sch Med & Hlth Sci, Joondalup, WA 6027, Australia
[3] Univ Valencia, Res Grp Prevent & Hlth Exercise & Sport, Valencia 46010, Spain
关键词
isoinertial; velocity-based training; encoder; validity; reliability; PERFORMANCE; ADAPTATIONS; SINGLE;
D O I
10.3390/s23042193
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The aim of this study was to examine the validity and reliability of an Inertial Measurement System integrated into a secondary pulley (IMS) for determining linear velocity during flywheel squat exercises. Thirty-one male participants who were highly experienced in a flywheel resistance exercise training performed flywheel squat exercises with three incremental loads, and mean velocity (MV), mean propulsive velocity (MPV) and max velocity (Vmax) of the exercises were simultaneously recorded with a validated linear encoder and the IMS, in two different sessions. Validity was analyzed using ordinary least products regression (OLP), Lin's concordance correlation coefficient (CCC), and Hedge's g for the values from the linear encoder and the IMS. Test-retest reliability was determined by coefficient of variation (CV), Intraclass correlation coefficient (ICC), and standard error of measurement (SEM). Results showed a high degree of validity (OLP intercept = -0.09-0.00, OLP slope = 0.95-1.04, CCC = 0.96-0.99, Hedge's g < 0.192, SEM = 0.04-0.08) and reliability (CV < 0.21%, ICC > 0.88, SEM < 0.08). These results confirm that the IMS provides valid and reliable measures of movement velocity during flywheel squat exercises.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Validity and reliability of a flywheel squat test in sport
    Beato, Marco
    Fleming, Adam
    Coates, Alexander
    Dello Iacono, Antonio
    [J]. JOURNAL OF SPORTS SCIENCES, 2021, 39 (05) : 482 - 488
  • [2] VALIDITY AND RELIABILITY OF THE PUSH WEARABLE DEVICE TO MEASURE MOVEMENT VELOCITY DURING THE BACK SQUAT EXERCISE
    Balsalobre-Fernandez, Carlos
    Kuzdub, Matt
    Poveda-Ortiz, Pedro
    del Campo-Vecino, Juan
    [J]. JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2016, 30 (07) : 1968 - 1974
  • [3] Validity and reliability of the WIMU® system to measure barbell velocity during the half-squat exercise
    Garcia-Pinillos, Felipe
    Latorre-Roman, Pedro A.
    Valdivieso-Ruano, Fernando
    Balsalobre-Fernandez, Carlos
    Parraga-Montilla, Juan A.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART P-JOURNAL OF SPORTS ENGINEERING AND TECHNOLOGY, 2019, 233 (03) : 408 - 415
  • [4] Validity and reliability of a novel optoelectronic device to measure movement velocity, force and power during the back squat exercise
    Laza-Cagigas, Roberto
    Goss-Sampson, Mark
    Larumbe-Zabala, Eneko
    Termkolli, Leke
    Naclerio, Fernando
    [J]. JOURNAL OF SPORTS SCIENCES, 2019, 37 (07) : 795 - 802
  • [5] Concurrent validity and reliability of a novel wireless inertial measurement system to assess trunk movement
    Bauer, C. M.
    Rast, F. M.
    Ernst, M. J.
    Kool, J.
    Oetiker, S.
    Rissanen, S. M.
    Suni, J. H.
    Kankaanpaa, M.
    [J]. JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2015, 25 (05) : 782 - 790
  • [6] VALIDITY AND RELIABILITY OF A WEARABLE INERTIAL SENSOR TO MEASURE VELOCITY AND POWER IN THE BACK SQUAT AND BENCH PRESS
    Orange, Samuel T.
    Metcalfe, James W.
    Liefeith, Andreas
    Marshall, Phil
    Madden, Leigh A.
    Fewster, Connor R.
    Vince, Rebecca V.
    [J]. JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2019, 33 (09) : 2398 - 2408
  • [7] Validity and reliability of an optoelectronic system to measure movement velocity during bench press and half squat in a Smith machine
    Muniz-Pardos, Borja
    Lozano-Berges, Gabriel
    Marin-Puyalto, Jorge
    Gonzalez-Aguero, Alex
    Vicente-Rodriguez, German
    Casajus, Jose A.
    Garatachea, Nuria
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART P-JOURNAL OF SPORTS ENGINEERING AND TECHNOLOGY, 2020, 234 (01) : 88 - 97
  • [8] Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity
    Al-Amri, Mohammad
    Nicholas, Kevin
    Button, Kate
    Sparkes, Valerie
    Sheeran, Liba
    Davies, Jennifer L.
    [J]. SENSORS, 2018, 18 (03):
  • [9] Reliability and concurrent validity of the Velowin optoelectronic system to measure movement velocity during the free-weight back squat
    Garcia-Ramos, Amador
    Perez-Castilla, Alejandro
    Martin, Fernando
    [J]. INTERNATIONAL JOURNAL OF SPORTS SCIENCE & COACHING, 2018, 13 (05) : 737 - 742
  • [10] Validity and Test-Retest Reliability of the Vmaxpro Sensor for Evaluation of Movement Velocity in the Deep Squat
    Feuerbacher, Joshua F.
    Jacobs, Mats W.
    Dragutinovic, Boris
    Goldmann, Jan-Peter
    Cheng, Sulin
    Schumann, Moritz
    [J]. JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2023, 37 (01) : 35 - 40