Development of a skin temperature measuring system for non-contact stress evaluation

被引:0
|
作者
Kataoka, H [1 ]
Kano, H [1 ]
Yoshida, H [1 ]
Saijo, A [1 ]
Yasuda, M [1 ]
Osumi, M [1 ]
机构
[1] Sanyo Elect Co Ltd, Mechatron Res Ctr, Hirakata, Osaka 5738534, Japan
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Skin temperature is an effective indicator for objectively evaluating human sensations, because it is controlled by sympathetic nerve activity which reflects the course of information processing in the brain. In this paper, we show a method to evaluate stress from skin temperature and an equipment which continuously measures skin temperature of an subject working in front of a computer terminal. An experiment is performed to investigate a relationship between stressfull task and the skin temperature. The experiment shows that there is a high correlation among stress, skin temperatures on nose and forehead. From this experiment, a regression equation is derived which computes the intensity of stress from skin temperatures on nose and forehead. A non-contact skin temperature measuring system is developed based on knowledge obtained in the experiment. The system comprised of an infrared camera, color camera, image processing unit and work station. The features are the abilities to track nose and forehead positions of an subject doing computer operation automatically and to evaluate the stress continuously.
引用
收藏
页码:940 / 943
页数:4
相关论文
共 50 条
  • [41] Study of a non-contact position measuring method
    Wang, Zhi-Qian
    Xie, Mu-Jun
    Qiao, Yan-Feng
    Guangxue Jishu/Optical Technique, 2003, 29 (04): : 431 - 433
  • [42] Non-contact measuring - A comparison of position sensors
    Dorißen, Hans Theo
    Dürkopp, Klaus
    Irle, Henning
    AutoTechnology, 2005, 5 (APR.): : 68 - 71
  • [43] Non-contact transport system
    Morishita, M
    JOURNAL OF JAPANESE SOCIETY OF TRIBOLOGISTS, 1997, 42 (11) : 859 - 864
  • [44] INDUCTIVE NON-CONTACT METHOD FOR MEASURING A VELOCITY
    GAJEWSKI, JB
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1983, 16 (07): : 622 - 624
  • [45] Non-Contact Measuring of Manufacturing Technology.
    Pfeifer, Tilo
    Steger, Hans-Werner
    VDI-Z, 1986, 128 (17): : 629 - 634
  • [46] Social development in contact and non-contact sports
    Baledi, Reza
    Mohammadi, Farzad
    Asefirad, Arash
    4TH WORLD CONFERENCE ON EDUCATIONAL SCIENCES (WCES-2012), 2012, 46 : 347 - 349
  • [47] Evaluation of biometric methods for measuring the anterior chamber depth in the non-contact mode
    Meinhardt, B
    Stachs, O
    Stave, J
    Beck, R
    Guthoff, R
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 244 (05) : 559 - 564
  • [48] Design and Clinical Evaluation of a Non-Contact Heart Rate Variability Measuring Device
    Kranjec, Jure
    Begus, Samo
    Gersak, Gregor
    Sinkovec, Matjaz
    Drnovsek, Janko
    Hudoklin, Domen
    SENSORS, 2017, 17 (11)
  • [49] Evaluation of biometric methods for measuring the anterior chamber depth in the non-contact mode
    B. Meinhardt
    O. Stachs
    J. Stave
    R. Beck
    R. Guthoff
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2006, 244 : 559 - 564
  • [50] Robustness evaluation of the non-contact inner diameter measuring device with micrometer order
    Mitsunari, Toshiyasu
    Okamoto, Yuji
    Nozawa, Itta
    Yamazaki, Kazunori
    OPTICAL METROLOGY AND INSPECTION FOR INDUSTRIAL APPLICATIONS V, 2018, 10819