Improved Automatic Detection of New T2 Lesions in Multiple Sclerosis Using Deformation Fields

被引:26
|
作者
Cabezas, M. [1 ,3 ]
Corral, J. F. [1 ]
Oliver, A. [3 ]
Diez, Y. [3 ]
Tintore, M. [2 ]
Auger, C. [1 ]
Montalban, X. [2 ]
Llado, X. [3 ]
Pareto, D. [1 ]
Rovira, A. [1 ]
机构
[1] Autonomous Univ Barcelona, Vall dHebron Res Inst, Vall dHebron Univ Hosp, Sect Neuroradiol,Dept Radiol, Barcelona, Spain
[2] Autonomous Univ Barcelona, Ctr Esclerosi Multiple Catalunya, Vall dHebron Univ Hosp, Dept Neurol Neuroimmunol,Vall dHebron Res Inst, Barcelona, Spain
[3] Univ Girona, Visio Comp & Robt Grp, Girona, Spain
关键词
BRAIN MRI; DISEASE-ACTIVITY; INTERFERON-BETA; RECOMMENDATIONS; IMAGES; MS;
D O I
10.3174/ajnr.A4829
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Detection of disease activity, defined as new/enlarging T2 lesions on brain MR imaging, has been proposed as a biomarker in MS. However, detection of new/enlarging T2 lesions can be hindered by several factors that can be overcome with image subtraction. The purpose of this study was to improve automated detection of new T2 lesions and reduce user interaction to eliminate inter- and intraobserver variability. MATERIALS AND METHODS: Multiparametric brain MR imaging was performed at 2 time points in 36 patients with new T2 lesions. Images were registered by using an affine transformation and the Demons algorithm to obtain a deformation field. After affine registration, images were subtracted and a threshold was applied to obtain a lesion mask, which was then refined by using the deformation field, intensity, and local information. This pipeline was compared with only applying a threshold, and with a state-of-the-art approach relying only on image intensities. To assess improvements, we compared the results of the different pipelines with the expert visual detection. RESULTS: The multichannel pipeline based on the deformation field obtained a detection Dice similarity coefficient close to 0.70, with a false-positive detection of 17.8% and a true-positive detection of 70.9%. A statistically significant correlation (r = 0.81, P value = 2.2688e-09) was found between visual detection and automated detection by using our approach. CONCLUSIONS: The deformation field-based approach proposed in this study for detecting new/enlarging T2 lesions resulted in significantly fewer false-positives while maintaining most true-positives and showed a good correlation with visual detection annotations. This approach could reduce user interaction and inter- and intraobserver variability.
引用
收藏
页码:1816 / 1823
页数:8
相关论文
共 50 条
  • [41] Improved Clinical Detection of Cerebellar Lesions in Multiple Sclerosis Patients
    Ayeni, Oluwasheyi
    Krieger, Stephen
    Brandstadter, Rachel
    Harel, Asaff
    Petracca, Maria
    Lewis, Christina
    Lublin, Fred
    Miller, Aaron
    Pelle, Gabrielle
    Pepe, Alessio
    Inglese, Matilde
    Sumowski, James
    NEUROLOGY, 2018, 90
  • [42] MIMoSA: An Approach to Automatically Segment T2 Hyperintense and T1 Hypointense Lesions in Multiple Sclerosis
    Valcarcel, Alessandra M.
    Linn, Kristin A.
    Khalid, Fariha
    Vandekar, Simon N.
    Tauhid, Shahamat
    Satterthwaite, Theodore D.
    Muschelli, John
    Bakshi, Rohit
    Shinohara, Russell T.
    BRAINLESION: GLIOMA, MULTIPLE SCLEROSIS, STROKE AND TRAUMATIC BRAIN INJURIES, BRAINLES 2018, PT I, 2019, 11383 : 47 - 56
  • [43] Automated White Matter Hyperintensity Detection in Multiple Sclerosis Using 3D T2 FLAIR
    Zhong, Yi
    Utriainen, David
    Wang, Ying
    Kang, Yan
    Haacke, E. Mark
    INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2014, 2014
  • [44] T2 relaxation time histograms in multiple sclerosis
    Grenier, D
    Pelletier, D
    Normandeau, M
    Newitt, D
    Nelson, S
    Goodkin, DE
    Majumdar, S
    MAGNETIC RESONANCE IMAGING, 2002, 20 (10) : 733 - 741
  • [45] Cortical and subcortical T2 shortening in multiple sclerosis
    Russo, C
    Smoker, WRK
    Kubal, W
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1997, 18 (01) : 124 - 126
  • [46] Assessing the usability of synthetic images to improve the detection of new T2 lesions
    Valencia, L.
    Valverde, S.
    Clerigues, A.
    Oliver, A.
    Corral, J. F.
    Rovira, A.
    Llado, X.
    MULTIPLE SCLEROSIS JOURNAL, 2021, 27 (2_SUPPL) : 480 - 480
  • [47] Improved Visualization of Cortical Lesions in Multiple Sclerosis Using 7T MP2RAGE
    Beck, E. S.
    Sati, P.
    Sethi, V.
    Kober, T.
    Dewey, B.
    Bhargava, P.
    Nair, G.
    Cortese, I. C.
    Reich, D. S.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (03) : 459 - 466
  • [48] Improved visualization of cortical lesions in multiple sclerosis using MP2RAGE at 7T
    Beck, E. S.
    Sati, P.
    Sethi, V.
    Kober, T.
    Bhargava, P.
    Dewey, B.
    Nair, G.
    Cortese, I. C.
    Reich, D. S.
    MULTIPLE SCLEROSIS JOURNAL, 2017, 23 : 230 - 230
  • [49] Fully automatic detection of deep white matter T1 hypointense lesions in multiple sclerosis
    Spies, Lothar
    Tewes, Anja
    Suppa, Per
    Opfer, Roland
    Buchert, Ralph
    Winkler, Gerhard
    Raji, Alaleh
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (23): : 8323 - 8337
  • [50] Automatic segmentation of white matter and detection of active lesions in multiple sclerosis
    Afzal, H. M. R.
    Luo, S.
    Ramadan, S.
    Lechner-Scott, J.
    MULTIPLE SCLEROSIS JOURNAL, 2018, 24 : 180 - 180