Improved Automatic Detection of New T2 Lesions in Multiple Sclerosis Using Deformation Fields

被引:26
|
作者
Cabezas, M. [1 ,3 ]
Corral, J. F. [1 ]
Oliver, A. [3 ]
Diez, Y. [3 ]
Tintore, M. [2 ]
Auger, C. [1 ]
Montalban, X. [2 ]
Llado, X. [3 ]
Pareto, D. [1 ]
Rovira, A. [1 ]
机构
[1] Autonomous Univ Barcelona, Vall dHebron Res Inst, Vall dHebron Univ Hosp, Sect Neuroradiol,Dept Radiol, Barcelona, Spain
[2] Autonomous Univ Barcelona, Ctr Esclerosi Multiple Catalunya, Vall dHebron Univ Hosp, Dept Neurol Neuroimmunol,Vall dHebron Res Inst, Barcelona, Spain
[3] Univ Girona, Visio Comp & Robt Grp, Girona, Spain
关键词
BRAIN MRI; DISEASE-ACTIVITY; INTERFERON-BETA; RECOMMENDATIONS; IMAGES; MS;
D O I
10.3174/ajnr.A4829
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Detection of disease activity, defined as new/enlarging T2 lesions on brain MR imaging, has been proposed as a biomarker in MS. However, detection of new/enlarging T2 lesions can be hindered by several factors that can be overcome with image subtraction. The purpose of this study was to improve automated detection of new T2 lesions and reduce user interaction to eliminate inter- and intraobserver variability. MATERIALS AND METHODS: Multiparametric brain MR imaging was performed at 2 time points in 36 patients with new T2 lesions. Images were registered by using an affine transformation and the Demons algorithm to obtain a deformation field. After affine registration, images were subtracted and a threshold was applied to obtain a lesion mask, which was then refined by using the deformation field, intensity, and local information. This pipeline was compared with only applying a threshold, and with a state-of-the-art approach relying only on image intensities. To assess improvements, we compared the results of the different pipelines with the expert visual detection. RESULTS: The multichannel pipeline based on the deformation field obtained a detection Dice similarity coefficient close to 0.70, with a false-positive detection of 17.8% and a true-positive detection of 70.9%. A statistically significant correlation (r = 0.81, P value = 2.2688e-09) was found between visual detection and automated detection by using our approach. CONCLUSIONS: The deformation field-based approach proposed in this study for detecting new/enlarging T2 lesions resulted in significantly fewer false-positives while maintaining most true-positives and showed a good correlation with visual detection annotations. This approach could reduce user interaction and inter- and intraobserver variability.
引用
收藏
页码:1816 / 1823
页数:8
相关论文
共 50 条
  • [1] Evaluating the sensitivity of subtraction imaging for the detection of new T2 multiple sclerosis lesions when using visual analysis, semiautomatic and automatic approaches
    Cabezas, M.
    Corral, J. F.
    Oliver, A.
    Llado, X.
    Auger, C.
    Sastre-Garriga, J.
    Tintore, M.
    Pareto, D.
    Montalban, X.
    Rovira, A.
    MULTIPLE SCLEROSIS JOURNAL, 2015, 21 : 175 - 175
  • [2] Improved interobserver agreement for visual detection of active T2 lesions on serial MR scans in multiple sclerosis using image registration
    Tan, IL
    van Schijndel, RA
    Fazekas, F
    Filippi, M
    Freitag, P
    Miller, DH
    Yousry, TA
    Pouwels, PJW
    Adèr, HJ
    Quist, MJ
    Barkhof, F
    JOURNAL OF NEUROLOGY, 2001, 248 (09) : 789 - 794
  • [3] Improved interobserver agreement for visual detection of active T2 lesions on serial MR scans in multiple sclerosis using image registration
    I Leng Tan
    Ronald A. van Schijndel
    Franz Fazekas
    Massimo Filippi
    Peter Freitag
    David H. Miller
    Tarek A. Yousry
    Petra J. W. Pouwels
    Hermann J. Adèr
    Marcel J. Quist
    Frederik Barkhof
    Journal of Neurology, 2001, 248 : 789 - 794
  • [4] Supervised detection of newly appearing T2-w multiple sclerosis lesions with subtraction and deformation fields features
    Salem, M.
    Cabezas, M.
    Valverde, S.
    Pareto, D.
    Oliver, A.
    Salvi, J.
    Rovira, A.
    Llado, X.
    MULTIPLE SCLEROSIS JOURNAL, 2017, 23 : 794 - 794
  • [5] T2 lesions and rate of progression of disability in multiple sclerosis
    Mostert, J. P.
    Koch, M. W.
    Steen, C.
    Heersema, D. J.
    de Groot, J. C.
    De Keyser, J.
    EUROPEAN JOURNAL OF NEUROLOGY, 2010, 17 (12) : 1471 - 1475
  • [6] Serial linking of T2 lesions in patients with multiple sclerosis
    Chandrasekhar, R
    Dwyer, MG
    Sampath, T
    Lema, JM
    Srinivasaraghavan, B
    Zivadinov, R
    MULTIPLE SCLEROSIS, 2005, 11 : S148 - S148
  • [7] Simultaneous T2 and T2*mapping of multiple sclerosis lesions with radial RARE-EPI
    Herrmann, Carl J. J.
    Els, Antje
    Boehmert, Laura
    Periquito, Joao
    Eigentler, Thomas Wilhelm
    Millward, Jason M.
    Waiczies, Sonia
    Kuchling, Joseph
    Paul, Friedemann
    Niendorf, Thoralf
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (03) : 1383 - 1402
  • [8] New T2 lesions enable an earlier diagnosis of multiple sclerosis in clinically isolated syndromes
    Dalton, CM
    Brex, PA
    Miszkiel, KA
    Fernando, K
    MacManus, DG
    Plant, GT
    Thompson, AJ
    Miller, DH
    ANNALS OF NEUROLOGY, 2003, 53 (05) : 673 - 676
  • [9] Editorial: Automatic methods for multiple sclerosis new lesions detection and segmentation
    Commowick, Olivier
    Combes, Benoit
    Cervenansky, Frederic
    Dojat, Michel
    FRONTIERS IN NEUROSCIENCE, 2023, 17
  • [10] Assessment of automatic decision-support systems for detecting active T2 lesions in multiple sclerosis patients
    Rovira, Alex
    Corral, Juan Francisco
    Auger, Cristina
    Valverde, Sergi
    Vidal-Jordana, Angela
    Oliver, Arnau
    de Barros, Andrea
    Ng Wong, Yiken Karelys
    Tintore, Mar
    Pareto, Deborah
    Aymerich, Francesc Xavier
    Montalban, Xavier
    Llado, Xavier
    Alonso, Juli
    MULTIPLE SCLEROSIS JOURNAL, 2022, 28 (08) : 1209 - 1218