Oxygen Transfer of Fine-Bubble Aeration in Activated Sludge Treating Saline Industrial Wastewater

被引:2
|
作者
Behnisch, Justus [1 ]
Schwarz, Maximilian [1 ]
Trippel, Jana [1 ]
Engelhart, Markus [1 ]
Wagner, Martin [1 ]
机构
[1] Tech Univ Darmstadt, Dept Civil & Environm Engn, Inst IWAR, Franziska Braun St 7, D-64287 Darmstadt, Germany
关键词
saline industrial wastewater; diffuser membrane design; critical coalescence concentration; transition concentration; disc diffuser; MASS-TRANSFER COEFFICIENT; AQUEOUS-SOLUTIONS; ELECTROLYTES; SYSTEMS; WWTPS; SIZE;
D O I
10.3390/w14121964
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Aeration is usually the most energy-intensive part of the activated sludge process, accounting for 50% to 80% of the total requirement. To achieve high efficiency, designers and operators of WWTPs must, therefore, consider all influencing factors, including salinity. With increasing salinity, oxygen transfer increases compared to tap water (TW), due to the inhibition of bubble coalescence. Previous saline water (SW) experiments showed that by using small slits in the diffuser membrane design, oxygen transfer and aeration efficiency increase further. In this study, we present a modified approach for considering the salt effect on oxygen transfer and assess the transferability of SW results to saline-activated sludge (sAS) conditions. Therefore, we operated a pilot-activated sludge plant over 269 days with a saline industrial wastewater influent. The oxygen transfer of disc-diffusers with two different membrane designs was measured continuously via the off-gas method. The salt concentration (c(Salt)) measured via ion analysis ranged between 4.9 and 11 g/L. Despite a high c(Salt) fluctuation, COD elimination was >90% all the time. Our results confirm previous SW results. Oxygen transfer in sAS is up to three times higher compared to non-saline conditions. Aeration efficiency shows that despite a higher pressure drop, diffusers with smaller slits are to be recommended in order to improve aeration in sAS.
引用
收藏
页数:21
相关论文
共 50 条
  • [21] Transfer number in fine bubble diffused aeration systems
    Capela, S
    Roustan, M
    Héduit, A
    [J]. WATER SCIENCE AND TECHNOLOGY, 2001, 43 (11) : 145 - 152
  • [22] Energy, cost and design aspects of coarse- and fine-bubble aeration systems in the MBBR IFAS process
    Sander, S.
    Behnisch, J.
    Wagner, M.
    [J]. WATER SCIENCE AND TECHNOLOGY, 2017, 75 (04) : 890 - 897
  • [23] Effects of air diffuser arrangement on hydrodynamics and oxygen transfer in activated sludge aeration tanks
    Fujie, K
    Kasakura, T
    Tsuchiya, K
    Tomita, Y
    [J]. ENVIRONMENTAL TECHNOLOGY, 1997, 18 (06) : 663 - 668
  • [25] Treatment of Hospital Wastewater Using Activated Sludge with Extended Aeration
    Custodio, Maria
    Cuadrado-Campo, Walter
    Penaloza, Richard
    Vicuna-Orihuela, Carmela
    Torres-Gutierrez, Elmer
    Orellana, Edith
    [J]. JOURNAL OF ECOLOGICAL ENGINEERING, 2022, 23 (11): : 24 - 32
  • [26] Effect of activated sludge acclimation aeration time on bayberry wastewater
    Shi, Liang
    He, Lingfeng
    Zhang, Yongli
    [J]. 2017 INTERNATIONAL SYMPOSIUM ON APPLICATION OF MATERIALS SCIENCE AND ENERGY MATERIALS (SAMSE 2017), 2018, 322
  • [27] CULTIVATION OF MARINE ACTIVATED SLUDGE TO TREAT SALINE WASTEWATER
    Tan, Songwen
    Acquah, Isaac
    Li, Weiguo
    [J]. FRESENIUS ENVIRONMENTAL BULLETIN, 2016, 25 (08): : 3134 - 3141
  • [28] Assessing biomass diversity and performance of an activated sludge process treating saline table olive processing wastewater
    Lazrak, Asma
    Mandi, Laila
    Djeni, Theodore N.
    Neffa, Mounsef
    Ouazzani, Naaila
    [J]. ENVIRONMENTAL TECHNOLOGY, 2019, 40 (20) : 2608 - 2619
  • [29] Factors affecting fine bubble creation and bubble size for activated sludge
    Alkhalidi, Ammar A. T.
    Amano, R. S.
    [J]. WATER AND ENVIRONMENT JOURNAL, 2015, 29 (01) : 105 - 113
  • [30] INFLUENCE OF MIXING ON ACTIVATED SLUDGE PROCESS IN INDUSTRIAL AERATION BASINS
    OTTENGRAF, SP
    RIETEMA, K