Modelling Curved Contact Flexible Microstrip Applicators for Patient-Specific Superficial Hyperthermia Treatment Planning

被引:7
|
作者
Kok, H. Petra [1 ]
Groen, Jort [1 ]
Bakker, Akke [1 ]
Crezee, Johannes [1 ]
机构
[1] Univ Amsterdam, Amsterdam UMC, Dept Radiat Oncol, NL-1105 AZ Amsterdam, Netherlands
关键词
hyperthermia; electromagnetic; antenna; treatment planning; RF heating; WAVE-GUIDE APPLICATOR; CFMA-434; APPLICATORS; BREAST-CANCER; 70; MHZ; RADIOTHERAPY; TEMPERATURE; PERFORMANCE; TUMORS;
D O I
10.3390/cancers12030656
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
This paper describes a method to reconstruct bendable superficial hyperthermia applicators for routine clinical patient-specific treatment planning. The reconstruction uses a CT scan with a flexible silicone dummy applicator positioned on the patient. The curvature was approximated by two second-degree polynomial functions. A realistic treatment series was mimicked using a standard Alderson radiation therapy phantom and a treatment planning model was reconstructed from a CT scan. The variation among treatment curvatures was compared to the modelled curvature. The mathematical approximation of the applicator curvature was validated for this phantom experiment, as well as for clinical treatments. The average maximum variation among the successive mimicked sessions was 3.67 +/- 0.69 mm (range 2.98-4.60 mm). The maximum deviation between the treatment curvature and the modelled curvature was 4.35 mm. Comparing the treatment and approximated curvature yielded a maximum deviation between 2.98 mm and 4.12 mm. For clinical treatments the maximum deviation of the treatment and approximated curvature varied between 0.48 mm and 1.98 mm. These results allow adequate reconstruction of bendable hyperthermia applicators for treatment planning, which can further improve treatment quality, for example by optimizing the water bolus temperature for patient-specific tumor depths. Predictive parameters for hyperthermia treatment outcome can easily be evaluated and compared for various input parameters.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] SAR characteristics of three types of contact flexible microstrip applicators for superficial hyperthermia
    LaMaitre, G
    VanDijk, JDP
    Gelvich, EA
    Wiersma, J
    Schneider, CJ
    [J]. INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1996, 12 (02) : 255 - 269
  • [2] Advanced patient-specific hyperthermia treatment planning
    Gavazzi, Soraya
    van Lier, Astrid L. H. M. W.
    Zachiu, Cornel
    Jansen, Eric
    Lagendijk, Jan J. W.
    Stalpers, Lukas J. A.
    Crezee, Hans
    Kok, H. Petra
    [J]. INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2020, 37 (01) : 992 - 1007
  • [3] Body Conformal Antennas for Superficial Hyperthermia: The Impact of Bending Contact Flexible Microstrip Applicators on Their Electromagnetic Behavior
    Correia, Davi
    Kok, H. Petra
    de Greef, Martijn
    Bel, Arjan
    van Wieringen, Niek
    Crezee, Johannes
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (12) : 2917 - 2926
  • [4] 3D Printed Patient-Specific Surface Mould Applicators for Brachytherapy Treatment of Superficial Lesions
    Cumming, I.
    Joshi, C. P.
    Lasso, A.
    Rankin, A.
    Falkson, C.
    Schreiner, L. John
    Fichtinger, G.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 222 - 222
  • [5] Theoretical modelling of thermal response in the tissue, made by contact flexible applicators at microwave hyperthermia
    Pavlysh, VA
    Kostjuk, IV
    Stasevich, SP
    [J]. 11TH INTERNATIONAL CONFERENCE MICROWAVE & TELECOMMUNICATION TECHNOLOGY, CONFERENCE PROCEEDINGS, 2001, : 90 - 91
  • [6] Patient-specific treatment planning for intraoperative radiotherapy of glioblastoma
    Alvarez, David Santiago Ayala
    Popovic, Marij
    Heng, Veng Jean
    Watson, Peter G. F.
    Evans, Michael D. C.
    Seuntjens, Jan
    [J]. MEDICAL PHYSICS, 2022, 49 (08) : 5711 - 5712
  • [7] Flexible Graphene Sheet Loaded Curved Patch Applicator for Superficial Hyperthermia Treatment Planning Utilizing Ripple Effect of Armchair and Zigzag Bending
    Singla, Alka
    Marwaha, Anupma
    Marwaha, Sanjay
    Rani, Surekha
    [J]. CURRENT NANOSCIENCE, 2023, 19 (04) : 589 - 600
  • [8] A New Approach to High-Quality Patient-Specific Hyperthermia Treatment
    Capstick, Myles
    Neufeld, Esra
    Gosselin, Marie-Christine
    Iliev, Dimce
    Renggli, Julien
    Selic, Danilo
    Rivara, Bruno
    Deubler, Steffen
    Guidon, Manuel
    Kuster, Niels
    [J]. 2015 9TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP), 2015,
  • [9] Dynamic, patient-specific mitral valve modelling for planning transcatheter repairs
    Ginty, Olivia K.
    Moore, John T.
    Eskandari, Mehdi
    Carnahan, Patrick
    Lasso, Andras
    Jolley, Matthew A.
    Monaghan, Mark
    Peters, Terry M.
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2019, 14 (07) : 1227 - 1235
  • [10] Dynamic, patient-specific mitral valve modelling for planning transcatheter repairs
    Olivia K. Ginty
    John T. Moore
    Mehdi Eskandari
    Patrick Carnahan
    Andras Lasso
    Matthew A. Jolley
    Mark Monaghan
    Terry M. Peters
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2019, 14 : 1227 - 1235