Dynamic, patient-specific mitral valve modelling for planning transcatheter repairs

被引:20
|
作者
Ginty, Olivia K. [1 ]
Moore, John T. [1 ]
Eskandari, Mehdi [2 ]
Carnahan, Patrick [1 ]
Lasso, Andras [3 ]
Jolley, Matthew A. [4 ]
Monaghan, Mark [2 ]
Peters, Terry M. [1 ,5 ]
机构
[1] Western Univ, Robarts Res Inst, London, ON N6A 5B7, Canada
[2] Kings Coll Hosp London, Denmark Hill, London SE5 9RS, England
[3] Queens Univ, Lab Percutaneous Surg, Kingston, ON K7L 3N6, Canada
[4] Univ Penn, Childrens Hosp Philadelphia, Dept Anesthesiol & Crit Care Med, Perelman Sch Med,Div Pediat Cardiol, Philadelphia, PA 19104 USA
[5] Western Univ, Sch Biomed Engn, Med Imaging, Dept Med Biophys, London, ON N6A 3K7, Canada
关键词
Modelling; Mitral valve; Mitral valve models; Surgical simulation; Transcatheter devices; 3D printing; REPLACEMENT;
D O I
10.1007/s11548-019-01998-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose:Transcatheter, beating heart repair techniques for mitral valve regurgitation is a very active area of development. However, it is difficult to both simulate and predict the clinical outcomes of mitral repairs, owing to the complexity of mitral valve geometry and the influence of hemodynamics. We aim to produce a workflow for manufacturing dynamic patient-specific models to simulate the mitral valve for transcatheter repair applications.Methods:In this paper, we present technology and associated workflow, for using transesophageal echocardiography to generate dynamic physical replicas of patient valves. We validate our workflow using six patient datasets representing patients with unique or particularly challenging pathologies as selected by a cardiologist. The dynamic component of the models and their resultant potential as procedure planning tools is due to a dynamic pulse duplicator that permits the evaluation of the valve models experiencing realistic hemodynamics.Results:Early results indicate the workflow has excellent anatomical accuracy and the ability to replicate regurgitation pathologies, as shown by colour Doppler ultrasound and anatomical measurements comparing patients and models. Analysis of all measurements successfully resulted in t critical two-tail > t stat and p values > 0.05, thus demonstrating no statistical difference between the patients and models, owing to high fidelity morphological replication.Conclusions:Due to the combination of a dynamic environment and patient-specific modelling, this workflow demonstrates a promising technology for simulating the complete morphology of mitral valves undergoing transcatheter repairs.
引用
收藏
页码:1227 / 1235
页数:9
相关论文
共 50 条
  • [1] Dynamic, patient-specific mitral valve modelling for planning transcatheter repairs
    Olivia K. Ginty
    John T. Moore
    Mehdi Eskandari
    Patrick Carnahan
    Andras Lasso
    Matthew A. Jolley
    Mark Monaghan
    Terry M. Peters
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2019, 14 : 1227 - 1235
  • [2] Patient-Specific Computer Modeling for the Planning of Transcatheter Mitral Valve Replacement
    de Jaegere, Peter
    Rajani, Ronak
    Prendergast, Bernard
    Van Mieghem, Nicolas M.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (08) : 956 - 958
  • [3] REPLY: Patient-Specific Computer Modeling for the Planning of Transcatheter Mitral Valve Replacement
    Guerrero, Mayra
    Urena, Marina
    Wang, Dee Dee
    O'Neill, William
    Feldman, Ted
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (08) : 958 - 958
  • [4] Patient-specific computational modelling of the mitral valve
    Kalozoumis, P.
    Morticelli, L.
    Haverich, A.
    Korossis, S.
    [J]. BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S882 - S882
  • [5] PATIENT-SPECIFIC MITRAL VALVE REPLICAS FOR PREOPERATIVE PLANNING OF MITRAL VALVE REPAIR
    Kruttschnitt, Michael
    Hassan, Nouray N.
    Tiemann, Klaus
    Hitschrich, Niklas
    Sodian, Ralf
    Lueth, Tim C.
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2019, VOL 3, 2020,
  • [6] Dynamic, Patient-Specific Mitral Valve Replicas for Anatomically Accurate Surgical Modelling
    Ginty, Olivia
    Moore, John
    Bainbridge, Dan
    Chu, Michael W. A.
    Peters, Terry
    [J]. FASEB JOURNAL, 2017, 31
  • [7] Patient-specific computer modelling - its role in the planning of transcatheter aortic valve implantation
    El Faquir, N.
    Ren, B.
    Van Mieghem, N. M.
    Bosmans, J.
    de Jaegere, P. P.
    [J]. NETHERLANDS HEART JOURNAL, 2017, 25 (02) : 100 - 105
  • [8] Patient-specific computer modelling – its role in the planning of transcatheter aortic valve implantation
    N. El Faquir
    B. Ren
    N. M. Van Mieghem
    J. Bosmans
    P. P. de Jaegere
    [J]. Netherlands Heart Journal, 2017, 25 : 100 - 105
  • [9] Patient-specific fluid simulation of transcatheter mitral valve replacement in mitral annulus calcification
    Hill, Samuel Joseph
    Young, Alistair
    Prendergast, Bernard
    Redwood, Simon
    Rajani, Ronak
    De Vecchi, Adelaide
    [J]. FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [10] Patient-specific access planning in minimally invasive mitral valve surgery
    Di Perna, Dario
    Castro, Miguel
    Gasc, Yannig
    Haigron, Pascal
    Verhoye, Jean-Philippe
    Anselmi, Amedeo
    [J]. MEDICAL HYPOTHESES, 2020, 136