A fast and sensitive method for the separation of carotenoids using ultra-high performance supercritical fluid chromatography-mass spectrometry

被引:41
|
作者
Jumaah, Firas [1 ]
Plaza, Merichel [1 ]
Abrahamsson, Victor [1 ]
Turner, Charlotta [1 ]
Sandahl, Margareta [1 ]
机构
[1] Lund Univ, Dept Chem, Ctr Anal & Synth, POB 124, S-22100 Lund, Sweden
基金
瑞典研究理事会;
关键词
Carotene; Xanthophyll; Orthogonal column screening; Method development; Supercritical fluid; Mass spectrometry; THIN-LAYER-CHROMATOGRAPHY; LIQUID-CHROMATOGRAPHY; STATIONARY PHASES; BETA-CAROTENE; MAJOR CAROTENOIDS; ALPHA-CAROTENE; CIS ISOMERS; VEGETABLES; FRUITS; FOODS;
D O I
10.1007/s00216-016-9707-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this study, a rapid and sensitive ultra-high performance supercritical fluid chromatography-mass spectrometry (UHPSFC-MS) method has been developed and partially validated for the separation of carotenoids within less than 6 min. Six columns of orthogonal selectivity were examined, and the best separation was obtained by using a 1-aminoanthracene (1-AA) column. The length of polyene chain as well as the number of hydroxyl groups in the structure of the studied carotenoids determines their differences in the physiochemical properties and thus the separation that is achieved on this column. All of the investigated carotenoids were baseline separated with resolution values greater than 1.5. The effects of gradient program, back pressure, and column temperature were studied with respect to chromatographic properties such as retention and selectivity. Electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) were compared in both positive and negative mode, using both direct infusion and hyphenated with UHPSFC. The ESI in positive mode provided the highest response. The coefficient of determination (R (2)) for all calibration curves were greater than 0.998. Limit of detection (LOD) was in the range of 2.6 and 25.2 ng/mL for alpha-carotene and astaxanthin, respectively, whereas limit of quantification (LOQ) was in the range of 7.8 and 58.0 ng/mL for alpha-carotene and astaxanthin, respectively. Repeatability and intermediate precision of the developed UHPSFC-MS method were determined and found to be RSD < 3 % and RSD < 6 %, respectively. The method was applied in order to determine carotenoids in supercritical fluid extracts of microalgae and rosehip.
引用
收藏
页码:5883 / 5894
页数:12
相关论文
共 50 条
  • [1] A fast and sensitive method for the separation of carotenoids using ultra-high performance supercritical fluid chromatography-mass spectrometry
    Firas Jumaah
    Merichel Plaza
    Victor Abrahamsson
    Charlotta Turner
    Margareta Sandahl
    [J]. Analytical and Bioanalytical Chemistry, 2016, 408 : 5883 - 5894
  • [2] A rapid method for the separation of vitamin D and its metabolites by ultra-high performance supercritical fluid chromatography-mass spectrometry
    Jumaah, Firas
    Larsson, Sara
    Essen, Sofia
    Cunico, Larissa P.
    Holm, Cecilia
    Turner, Charlotta
    Sandahl, Margareta
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2016, 1440 : 191 - 200
  • [3] Ultra-high performance supercritical fluid chromatography-mass spectrometry procedure for analysis of monosaccharides from plant gum binders
    Pauk, Volodymyr
    Pluhacek, Tomas
    Havlicek, Vladimir
    Lemr, Karel
    [J]. ANALYTICA CHIMICA ACTA, 2017, 989 : 112 - 120
  • [4] Comparison of ultra-high performance supercritical fluid chromatography and ultra-high performance liquid chromatography for the separation of spirostanol saponins
    Zhu, Ling-ling
    Zhao, Yang
    Xu, Yong-wei
    Sun, Qing-long
    Sun, Xin-guang
    Kang, Li-ping
    Yan, Ren-yi
    Zhang, Jie
    Liu, Chao
    Ma, Bai-ping
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 120 : 72 - 78
  • [5] Enantiomeric separation and quantification of citalopram in serum by ultra-high performance supercritical fluid chromatography-tandem mass spectrometry
    Hegstad, Solfrid
    Havnen, Hilde
    Helland, Arne
    Falch, Berit Margrethe Hasle
    Spigset, Olav
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1061 : 103 - 109
  • [6] SUPERCRITICAL FLUID CHROMATOGRAPHY-MASS SPECTROMETRY OF CAROTENOIDS AND OTHER POLAR LIPIDS
    FREW, NM
    JOHNSON, CG
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1987, 193 : 19 - AGFD
  • [7] Application of ultra-high performance supercritical fluid chromatography for the determination of carotenoids in dietary supplements
    Li, Bing
    Zhao, Haiyan
    Liu, Jing
    Liu, Wei
    Fan, Sai
    Wu, Guohua
    Zhao, Rong
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2015, 1425 : 287 - 292
  • [8] Ultra-high performance supercritical fluid chromatography method for separation and quantitation of saikosaponins in herbal medicine
    Sun, Tingting
    Luo, Jiaoyang
    Xu, Yuanyuan
    Sun, Xinqi
    Yang, Shihai
    Yang, Meihua
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 199
  • [9] Simple, rapid, and environmentally friendly method for the separation of isoflavones using ultra-high performance supercritical fluid chromatography
    Wu, Wenjie
    Zhang, Yuan
    Wu, Hanqiu
    Zhou, Weie
    Cheng, Yan
    Li, Hongna
    Zhang, Chuanbin
    Li, Lulu
    Huang, Ying
    Zhang, Feng
    [J]. JOURNAL OF SEPARATION SCIENCE, 2017, 40 (13) : 2827 - 2837
  • [10] Ultra-high-performance supercritical fluid chromatography-mass spectrometry for the analysis of organic contaminants in sediments
    Lubeck, Josephine S.
    Christensen, Jan H.
    Tomasi, Giorgio
    [J]. JOURNAL OF SEPARATION SCIENCE, 2023, 46 (01)