The effects of polyethylene cup thickness on wear of total hip prostheses

被引:18
|
作者
Oonishi, H
Iwaki, H
Kin, N
Kushitani, S
Murata, N
Wakitani, S
Imoto, K
机构
[1] Osaka Minami Natl Hosp, Biomat Res Lab, Kawachinagano, Osaka 586, Japan
[2] Osaka Minami Natl Hosp, Dept Orthopaed Surg, Artificial Joint Sect, Kawachinagano, Osaka 586, Japan
关键词
Polymer; Alumina; Molecular Weight; Polyethylene; Femoral Head;
D O I
10.1023/A:1008823518381
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The wear rate of the ultrahigh molecular weight polyethylene cups in combination with a 28 mm alumina femoral head was measured on the radiographs of patients without any complications, and on cups retrieved due to slight loosening of the prosthesis or due to late infection between bone and components. The wear rate on the radiographs did not include the initial wear, but the wear rate on the retrieved cups did include the initial wear. The wear rate on the retrieved cups was higher, by 50%, than that measured on the radiographs. In both cases, the thicker the polyethylene cups, the lower was the wear rate measured. The average wear rate of the 7 and 8 mm thick cups was about twice that of cups 10 and 11 mm thick. From these results, we conclude that: polyethylene cups more than 11 mm thick should be used.
引用
收藏
页码:475 / 478
页数:4
相关论文
共 50 条
  • [41] POLYETHYLENE WEAR AND LATE LOOSENING IN TOTAL HIP-REPLACEMENT - NEW PROSPECTIVES FOR METAL METAL PAIRING FOR BALL AND CUP
    WEBER, BG
    FIECHTER, T
    [J]. ORTHOPADE, 1989, 18 (05): : 370 - 376
  • [42] Low-wear effect of high-dose gamma-irradiated crosslinked polyethylene in total hip prostheses
    Oonishi, H
    Clarke, IC
    Good, VD
    Tsuji, E
    Ikada, Y
    Ishimaru, H
    Tateishi, T
    Fujisawa, A
    Masuda, S
    Kumakura, M
    [J]. JOINT ARTHROPLASTY, 1999, : 97 - 108
  • [43] WEAR OF THE POLYETHYLENE ACETABULAR CUP - METALLIC AND CERAMIC HEADS COMPARED IN A HIP SIMULATOR
    SAIKKO, VO
    PAAVOLAINEN, PO
    SLATIS, P
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1993, 64 (04): : 391 - 402
  • [44] A ROUGH-SURFACE AS A CAUSE OF WEAR OF THE CUP IN THE CHRISTIANSEN TOTAL HIP
    OHLIN, A
    ERIKSON, T
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (01): : 101 - 101
  • [45] FRICTION AND WEAR STUDIES ON TOTAL HIP-JOINT REPLACEMENT PROSTHESES
    SIMON, SR
    WEIGHTMA.BO
    PAUL, IL
    ROSE, RM
    RADIN, EL
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (03): : 661 - &
  • [46] Reduction of wear in total hip replacement prostheses by amorphous diamond coatings
    Lappalainen, R
    Selenius, M
    Anttila, A
    Konttinen, YT
    Santavirta, SS
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2003, 66B (01) : 410 - 413
  • [47] THE INFLUENCE OF CONTACT STRESS ON THE WEAR OF UHMWPE FOR TOTAL REPLACEMENT HIP PROSTHESES
    BARBOUR, PSM
    BARTON, DC
    FISHER, J
    [J]. WEAR, 1995, 181 : 250 - 257
  • [48] An in vitro wear study of alumina-alumina total hip prostheses
    Smith, SL
    Unsworth, A
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2001, 215 (H5) : 443 - 446
  • [49] Comparison of polyethylene wear in machined versus molded polyethylene in total hip prosthesis
    Courpied, JP
    Delhoume, J
    Kerboull, L
    Kerboull, M
    [J]. REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2000, 86 (01): : 10 - 14
  • [50] Influence of the manufacturing process in performance concerning wear of total hip prostheses
    A. L. L. Oliveira
    [J]. Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2014, 36 : 787 - 795