Evaluation of manual and automatic segmentation of the mouse heart from CINE MR images

被引:33
|
作者
Heijman, Edwin [1 ]
Aben, Jean-Paul [2 ]
Penners, Cindy [2 ]
Niessen, Petra [3 ]
Guillaume, Rene [2 ]
van Eys, Guillaume [3 ]
Nicolay, Klaas [1 ]
Strijkers, Gustav J. [1 ]
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, Biomed NMR, NL-5600 MB Eindhoven, Netherlands
[2] Pie Med Imaging BV, Maastricht, Netherlands
[3] Univ Maastricht, Cardiovasc Res Inst Maastricht, Dept Mol Genet, Maastricht, Netherlands
关键词
mouse heart; segmentation; quantitative analysis; CINE MRI; automatic; global functional parameter;
D O I
10.1002/jmri.21236
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare global functional parameters determined from a stack of cinematographic MR images of mouse heart by a manual segmentation and an automatic segmentation algorithm. Materials and Methods: The manual and automatic segmentation results of 22 mouse hearts were compared. The automatic segmentation was based on propagation of a minimum cost algorithm in polar space starting from manually drawn contours in one heart phase. Intra- and interobserver variability as well as validity of the automatic segmentation was determined. To test the reproducibility of the algorithm the variability was calculated from the intra and interobserver input. Results: The mean time of segmentation for one dataset was around 10 minutes and approximate to 2.5 hours for automatic and manual segmentation, respectively. There were no significant differences between the automatic and the manual segmentation except for the end systolic epicardial volume. The automatically derived volumes correlated well with the manually derived volumes (R-2 = 0.90); left ventricular mass with and without papillary muscle showed a correlation R 2 of 0.74 and 0.76, respectively. The manual intraobserver variability was superior to the interobserver variability and the variability of the automatic segmentation, while the manual interobserver variability was comparable to the variability of the automatic segmentation. The automatic segmentation algorithm reduced the bias of the intra- and interobserver variability. Conclusion: We conclude that automatic segmentation of the mouse heart provides a fast and valid alternative to manual segmentation of the mouse heart.
引用
收藏
页码:86 / 93
页数:8
相关论文
共 50 条
  • [1] Left ventricular mass:: Manual and automatic segmentation of true FISP and FLASH cine MR images in dogs and pigs
    François, CJ
    Fieno, DS
    Shors, SM
    Finn, JP
    RADIOLOGY, 2004, 230 (02) : 389 - 395
  • [2] Automatic Segmentation and Disease Classification Using Cardiac Cine MR Images
    Wolterink, Jelmer M.
    Leiner, Tim
    Viergever, Max A.
    Isgum, Ivana
    STATISTICAL ATLASES AND COMPUTATIONAL MODELS OF THE HEART: ACDC AND MMWHS CHALLENGES, 2018, 10663 : 101 - 110
  • [3] Comprehensive Segmentation of Cine Cardiac MR Images
    Fradkin, Maxim
    Ciofolo, Cybele
    Mory, Benoit
    Hautvast, Gilion
    Breeuwer, Marcel
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2008, PT I, PROCEEDINGS, 2008, 5241 : 178 - +
  • [4] Fast Fully Automatic Segmentation of the Myocardium in 2D Cine MR Images
    Queiros, Sandro
    Barbosa, Daniel
    Heyde, Brecht
    Morais, Pedro
    Friboulet, Denis
    Claus, Piet
    Bernard, Olivier
    D'hooge, Jan
    FUNCTIONAL IMAGING AND MODELING OF THE HEART, 2013, 7945 : 71 - 79
  • [5] Automatic segmentation of right ventricle in cardiac cine MR images using a saliency analysis
    Atehortua, Angelica
    Zuluaga, Maria A.
    Garcia, Juan D.
    Romero, Eduardo
    MEDICAL PHYSICS, 2016, 43 (12) : 6270 - 6281
  • [6] Myocardial Segmentation of Late Gadolinium Enhanced MR Images by Propagation of Contours from Cine MR Images
    Wei, Dong
    Sun, Ying
    Chai, Ping
    Low, Adrian
    Ong, Sim Heng
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI 2011, PT III, 2011, 6893 : 428 - +
  • [7] Automatic Segmentation of the Left Ventricle Cavity from Cine MRI Images
    Hadhoud, Marwa M. A.
    2018 9TH CAIRO INTERNATIONAL BIOMEDICAL ENGINEERING CONFERENCE (CIBEC), 2018, : 126 - 129
  • [8] Automatic segmentation of the bones from MR images of the knee
    Fripp, Jurgen
    Ourselin, Sebastien
    Warfield, Simon K.
    Crozier, Stuart
    2007 4TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING : MACRO TO NANO, VOLS 1-3, 2007, : 336 - +
  • [9] Semi-Automatic segmentation of multiple mouse embryos in MR images
    Leila Baghdadi
    Mojdeh Zamyadi
    John G Sled
    Jürgen E Schneider
    Shuomo Bhattacharya
    R Mark Henkelman
    Jason P Lerch
    BMC Bioinformatics, 12
  • [10] AUTOMATIC SEGMENTATION OF THE SCOLIOTIC SPINE FROM MR IMAGES
    Guerroumi, Nassim
    Playout, Clement
    Laporte, Catherine
    Cheriet, Farida
    2019 IEEE 16TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2019), 2019, : 480 - 484