Submillisievert imaging protocol using full reconstruction and advanced patient motion correction in 320-row area detector coronary CT angiography

被引:6
|
作者
Kawaguchi, Yuko [1 ]
Fujimoto, Shinichiro [1 ]
Takamura, Kazuhisa [1 ]
Kato, Etsuro [1 ]
Suda, Shoko [1 ]
Matsumori, Rie [1 ]
Hiki, Makoto [1 ]
Kumamaru, Kanako K. [2 ]
Daida, Hiroyuki [1 ]
机构
[1] Juntendo Univ, Dept Cardiovasc Med, Grad Sch Med, Bunkyo Ku, 2-1-1 Hongo, Tokyo 1138421, Japan
[2] Juntendo Univ, Dept Radiol, Grad Sch Med, Tokyo, Japan
来源
关键词
320-row area detector coronary computed tomography angiography; Full reconstruction; Advanced patient motion correction; Radiation dosing; Submillisievert; ROW COMPUTED-TOMOGRAPHY; ITERATIVE RECONSTRUCTION; DIAGNOSTIC-ACCURACY; ARTERY STENOSIS; QUALITY; FEASIBILITY; PERFORMANCE; SUBTRACTION; DISEASE;
D O I
10.1007/s10554-017-1237-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Radiation exposure remains a concern in the use of coronary CT angiography (CCTA). Full reconstruction (Full) and reconstruction using advanced patient motion correction (APMC) could obtain a lower radiation dose using low tube current scanning in a 320-row Area Detector CT (320-ADCT). The radiation dose for an imaging protocol using Full and APMC in daily practice was estimated. A total of 209 patients who underwent CCTA in 1 rotation scanning with 100 kv and adaptive iterative dose reduction 3D in 320-ADCT were enrolled. Imaging protocols were classified into 3 groups based on estimated slow filling time: (1) slow filling time >= 275 msec, Full with 30% of usual tube current (N = 43)(Full30%mA) (2) 206.3 msec <= slow filling time < 275 msec, APMC with 50% of usual tube current (N = 48)(APMC50%mA); and (3) 137.5 msec <= slow filling time < 206.3 msec, Half reconstruction with usual tube current (N = 118)(Half100%mA). Radiation dose was estimated by the effective dose. The diagnostic accuracy of CCTA was compared with that of invasive coronary angiography in 28 patients. The effective doses of Full30%mA, APMC50%mA, and Half100%mA were 0.77 +/- 0.31, 1.30 +/- 0.85, and 1.98 +/- 0.68, respectively. Of 28 patients, the sensitivity, specificity, accuracy, positive predictive value, and negative predictive value in vessel-based analyses were: Full30%mA, 66.7, 82.4, 80.0, 40.0, and 93.3%; APMC50%mA, 100.0, 80.0, 83.3, 50.05, and 100.0%; and Half100%mA, 90.9, 83.0, 86.3, 78.95, and 92.9%, respectively. An imaging protocol using Full30%mA and APMC50%mA was one of the methods how radiation dose could be reduced radiation dose maintained diagnostic accuracy compared to imaging using conventional Half100%mA.
引用
收藏
页码:465 / 474
页数:10
相关论文
共 50 条
  • [41] Subtraction Coronary CT Angiography for the Evaluation of Severely Calcified Lesions Using a 320-Detector Row Scanner
    Yoshioka K.
    Tanaka R.
    Current Cardiovascular Imaging Reports, 2011, 4 (6) : 437 - 446
  • [42] Quantification of coronary flow using dynamic angiography with 320-detector row CT and motion coherence image processing: Detection of ischemia for intermediate coronary stenosis
    Nagao, Michinobu
    Yamasaki, Yuzo
    Kamitani, Takeshi
    Kawanami, Satoshi
    Sagiyama, Koji
    Yamanouchi, Torahiko
    Shimomiya, Yamato
    Matoba, Tetsuya
    Mukai, Yasushi
    Odashiro, Keita
    Baba, Shingo
    Maruoka, Yasuhiro
    Kitamura, Yoshiyuki
    Nishie, Akihiro
    Honda, Hiroshi
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (05) : 996 - 1003
  • [43] Quantification of coronary flow using dynamic angiography with 320-detector row CT and motion coherence image processing: Detection of ischemia for intermediate coronary stenosis
    Qin, Jie
    Cai, Songwang
    Quan, Li
    Tang, Wenjie
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (16) : C126 - C126
  • [44] Body Size-Adapted Dose of Contrast Material and Scanning Protocol in 320-Detector Row CT Coronary Angiography
    Tatsugami, Fuminari
    Matsuki, Mitsuru
    Nakai, Go
    Inada, Yuki
    Kanazawa, Shuji
    Takeda, Yoshihiro
    Morita, Hideaki
    Takada, Haruhiko
    Yoshikawa, Shushi
    Fukumura, Katsunori
    Narumi, Yoshifumi
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (04) : 475 - 479
  • [45] Dynamic flow imaging using 320-detector row CT and motion coherence analysis in coronary aneurysms associated with Kawasaki disease
    Shimomiya, Yamato
    Nagao, Michinobu
    Yamasaki, Yuzo
    Shirasaka, Takashi
    Kondo, Masatoshi
    Kojima, Tsukasa
    Nishie, Akihiro
    Yamamura, Kenichiro
    Honda, Hiroshi
    CARDIOLOGY IN THE YOUNG, 2018, 28 (03) : 416 - 420
  • [46] Movement of the Eustachian Tube During Sniffing in Patients With Patulous Eustachian Tube: Evaluation Using a 320-Row Area Detector CT Scanner
    Yoshioka, Satoshi
    Naito, Kensei
    Fujii, Naoko
    Katada, Kazuhiro
    OTOLOGY & NEUROTOLOGY, 2013, 34 (05) : 877 - 883
  • [47] A “one-stop-shop” 4D CTA protocol using 320-row CT for advanced imaging in acute ischemic stroke: a technical note
    Julien Ognard
    Brieg Dissaux
    Karim Haioun
    Michel Nonent
    Jean-Christophe Gentric
    Douraïed Ben Salem
    European Radiology, 2019, 29 : 4930 - 4936
  • [48] The effect of bolus volume on laryngeal closure and UES opening in swallowing: Kinematic analysis using 320-row area detector CT study
    Shibata, S.
    Inamoto, Y.
    Saitoh, E.
    Kagaya, H.
    Aoyagi, Y.
    Ota, K.
    Akahori, R.
    Fujii, N.
    Palmer, J. B.
    Gonzalez-Fernandez, M.
    JOURNAL OF ORAL REHABILITATION, 2017, 44 (12) : 974 - 981
  • [49] A "one-stop-shop" 4D CTA protocol using 320-row CT for advanced imaging in acute ischemic stroke: a technical note
    Ognard, Julien
    Dissaux, Brieg
    Haioun, Karim
    Nonent, Michel
    Gentric, Jean-Christophe
    Ben Salem, Douraied
    EUROPEAN RADIOLOGY, 2019, 29 (09) : 4930 - 4936
  • [50] Dynamic Volumetric CT Angiography for the Detection and Classification of Endoleaks: Application of Cine Imaging Using a 320-Row CT Scanner with 16-cm Detectors
    Koike, Yuya
    Ishida, Kazufumi
    Hase, Soichiro
    Kobayashi, Yasuyuki
    Nishimura, Jun-ichi
    Yamasaki, Motoshige
    Hosaka, Norifumi
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 25 (08) : 1172 - 1180