Non-Invasive Measurement for Cardiac Variations Using a Fiber Optic Sensor

被引:20
|
作者
Lyu, Weimin [1 ]
Xu, Wei [2 ,3 ]
Yang, Fangang [4 ]
Chen, Shuyang [5 ]
Tan, Fengze [1 ]
Yu, Changyuan [5 ]
机构
[1] Hong Kong Polytech Univ, Shenzhen Res Inst, Shenzhen 518057, Peoples R China
[2] Chinese Acad Sci, State Key Lab Transient Opt & Photon, Xian Inst Opt & Precis Mech, Xian 710119, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Natl Univ Singapore, Dept Elect & Comp Engn, Singapore 119077, Singapore
[5] Hong Kong Polytech Univ, Dept Elect & Informat Engn, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
Optical fibers; fiber optic sensors; optical fiber interference; biomedical transducers; PULSE-WAVE VELOCITY; BALLISTOCARDIOGRAM;
D O I
10.1109/LPT.2021.3078757
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Cardiovascular diseases (CVDs) are very common in modern society, such as atherosclerosis, hypertension, etc., which have a great impact on heart function. Therefore, hospitalization monitoring alone is far from enough. Long-term monitoring of the heart is needed in daily life. The technology of non-invasive monitoring of the cardiovascular system can meet the needs of long-term monitoring of the heart condition, helping to promote the improvement of lifestyle and daily care, reducing the overall risk of developing CVDs. The purpose of this study is to investigate the cardiac response after different exercises using a 3 x 3 demodulation scheme-based ballisto-cardiography (BCG) monitoring system. A fiber optic sensor (FOS)-based smart cushion is used to replace the traditional inconvenient electrocardiogram (ECG) for heart rate variability (HRV). The correlation between BCG inter-beat interval (IBI) and ECG IBI is 0.9862, and the RMSE is 0.0139. The BCG signal can assess cardiac contractility by analyzing RJ interval with ECG, which is a practical alternative to the pre-ejection period (PEP).
引用
收藏
页码:990 / 993
页数:4
相关论文
共 50 条
  • [21] MEASUREMENT OF CARDIAC, PULMONARY AND VASCULAR FUNCTION USING NON-INVASIVE TECHNIQUES
    SHELLEY, T
    PHYSICS IN MEDICINE AND BIOLOGY, 1971, 16 (03): : 538 - &
  • [22] Helical long period fiber grating sensor for non-invasive measurement of vital signs
    Chen, Weijuan
    Zhang, Yi
    Chen, Zhihao
    Zhang, Hao
    Chen, Xiaogang
    Zhang, Yu
    Huang, Shuyan
    Hu, Xiaohua
    Zhang, Xianzeng
    OPTICS AND LASER TECHNOLOGY, 2023, 162
  • [23] Velocity measurement using MEMS ultrasonic sensor for non-invasive blood pressure measurement
    Takei Y.
    Matsui R.
    Minh-Dung N.
    Takahata T.
    Matsumoto K.
    Shimoyama I.
    IEEJ Transactions on Sensors and Micromachines, 2018, 138 (02) : 54 - 58
  • [24] Non-invasive Psychological signal Measurement with Photoelectric sensor
    Liou, Jian-Chiun
    Fang, Kuan-Wen
    2017 6TH INTERNATIONAL SYMPOSIUM ON NEXT GENERATION ELECTRONICS (ISNE), 2017,
  • [25] Non-Invasive Blood Components Measurement Using Optical Sensor System Interface
    Raikham, Pamshangphy
    Kumar, Rohit
    Shah, Rahul Kumar
    Hazarika, Mery
    Sonkar, R. K.
    2018 3RD INTERNATIONAL CONFERENCE ON MICROWAVE AND PHOTONICS (ICMAP), 2018,
  • [26] Non-invasive Measurement of Complex permittivity using a Compact Planar Microwave Sensor
    Moolat, Remsha
    Mani, Manoj
    Pezholil, Mohanan
    2022 3RD URSI ATLANTIC AND ASIA PACIFIC RADIO SCIENCE MEETING (AT-AP-RASC), 2022,
  • [27] Non-invasive measurement of chick embryo cardiac work
    Pawlak, K
    Niedziólka, J
    CZECH JOURNAL OF ANIMAL SCIENCE, 2004, 49 (01) : 8 - 15
  • [28] A novel approach to non-invasive measurement of cardiac output
    Klein, Michael
    Machina, Matt
    Battisti, Anne
    Pucci, Olivia
    Minkovich, Leonid
    Duffin, James
    Fisher, Joseph
    FASEB JOURNAL, 2011, 25
  • [29] NON-INVASIVE DOPPLER MEASUREMENT OF CARDIAC-OUTPUT
    TOUCHE, T
    NITENBERG, A
    LAFFAY, N
    DAHAN, M
    PRASQUIER, R
    PRESSE MEDICALE, 1984, 13 (27): : 1687 - 1692
  • [30] NON-INVASIVE METHOD FOR THE MEASUREMENT OF CARDIAC-OUTPUT
    NARUMI, J
    SUMA, K
    OHE, Y
    IWABUCHI, K
    UCHIYAMA, A
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1982, 46 (08): : 801 - 802