Miniature polymer transducers for high frequency medical imaging

被引:11
|
作者
Lockwood, GR [1 ]
Hazard, CR [1 ]
机构
[1] Cleveland Clin Fdn, Dept Biomed Engn, Cleveland, OH 44195 USA
关键词
high frequency ultrasound; polymer transducers; signal-to-noise ratio estimation; KLM model;
D O I
10.1117/12.308005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
High frequency (30-100 MHz) polymer transducers have been used in a variety of medical imaging applications(1,2) since they were first introduced by Sherar and Foster(3) in the late 1980s. The transducers are intrinsically broadband and the flexibility of the polymer material makes fabrication relatively easy. Unfortunately, piezoelectric polymer materials have a low dielectric constant. Unless a large aperture is used, the electrical impedance of the transducer will be high, and the receiver sensitivity will be poor. This problem can be avoided by placing a high impedance pre-amplifier inside the transducer housing. Placing the preamplifier close to the transducer is important to avoid standing waves between the high output impedance of the transducer and the high input impedance of the pre-amplifier. We have recently developed a process for fabricating high frequency spherically shaped polymer transducers in which an integrated circuit die is mounted just beneath the surface of the transducer. In this paper we describe a theoretical and experimental analysis of the noise performance of these devices. The signal-to-noise ratio at the output of the pre-amplifier is estimated by combining a simple noise model for the amplifier with a KLM model of the transducer. This analysis provides a useful way of evaluating different transducer/pre-amplifier combinations. Excellent agreement between the model predictions and experimental results proves the validity of this approach.
引用
收藏
页码:228 / 236
页数:9
相关论文
共 50 条
  • [21] Volume fraction gradient piezoelectric ceramic polymer composites for ultrasonic medical imaging transducers
    Panda, RK
    Kholkin, A
    Danforth, SC
    Safari, A
    [J]. DIELECTRIC CERAMIC MATERIALS, 1999, 100 : 409 - 418
  • [23] Ultrasonic transducers for medical diagnostic imaging
    Lee W.
    Roh Y.
    [J]. Biomedical Engineering Letters, 2017, 7 (2) : 91 - 97
  • [24] Fundamental Performance Characterisation of High Frequency Piezocomposites made with Net-shape Viscous Polymer Processing for Medical Ultrasound Transducers
    MacLennan, D.
    Button, T. W.
    Elgoyhen, J.
    Hughes, H.
    Meggs, C.
    Corner, G.
    Demore, C. E. M.
    Cochran, S.
    Zhang, D.
    [J]. 2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 58 - +
  • [25] High frequency ultrasound arrays for medical imaging
    Ritter, TA
    Shung, KK
    Cannata, J
    Shrout, TR
    [J]. 2000 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2000, : 1261 - 1264
  • [26] High frequency transducer arrays for medical imaging
    Ritter, T
    Shung, KK
    Tutwiler, R
    Shrout, T
    [J]. MEDICAL IMAGING 2000: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2000, 3982 : 208 - 216
  • [27] Ultrasonic transducers for high resolution imaging: From piezoelectric structures to medical diagnostics
    Lethiecq, M
    Levassort, F
    Tran-Huu-Hue, LP
    [J]. INFORMACIJE MIDEM-JOURNAL OF MICROELECTRONICS ELECTRONIC COMPONENTS AND MATERIALS, 2005, 35 (04): : 177 - 186
  • [28] Piezoceramics for high frequency (50 to 100 MHz) single element imaging transducers
    Zipparo, MJ
    Shung, KK
    Shrout, TR
    [J]. ULTRASONIC TRANSDUCER ENGINEERING: MEDICAL IMAGING 1997, 1997, 3037 : 148 - 157
  • [29] Design of 20 MHz convex array transducers for high frequency ophthalmic imaging
    Kim, Hyung Ham
    Chang, Jin Ho
    Cannata, Jonathan M.
    Shung, K. Kirk
    [J]. 2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 88 - 91
  • [30] Fabrication and Evaluation of High Frequency Ultrasound Receive Transducers for Intravascular Photoacoustic Imaging
    Lee, Jun-Su
    Chang, Jin Ho
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF KOREA, 2014, 33 (05): : 300 - 308