White-light Sagnac interferometer for snapshot multispectral imaging

被引:31
|
作者
Kudenov, Michael W. [1 ]
Jungwirth, Matthew E. L. [1 ]
Dereniak, Eustace L. [1 ]
Gerhart, Grant R. [2 ]
机构
[1] Univ Arizona, Coll Opt Sci, Tucson, AZ 85721 USA
[2] US Army TACOM, Warren, MI 48397 USA
关键词
CHLOROPHYLL CONTENT; POLARIMETER; REFLECTANCE; CALIBRATION;
D O I
10.1364/AO.49.004067
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The theoretical and experimental demonstration of a multispectral Sagnac interferometer (MSI) is presented. The MSI was created by including two multiple-order blazed diffraction gratings in both arms of a standard polarization Sagnac interferometer (PSI). By introducing these high-order diffractive structures, unique spectral passbands can be amplitude modulated onto coincident carrier frequencies. Extraction of the modulated multispectral images, corresponding to each passband, is accomplished within the Fourier domain. This yields a unique multispectral sensor capable of imaging all the passbands in a single snapshot. First, the theoretical operating principles of a PSI are discussed to provide a context for the MSI. This is followed by the theoretical and experimental development of the MSI, which is an extension of a dispersion-compensated PSI. Indoor and outdoor testing and validation of the MSI are performed by observing vegetation, demonstrating the ability of our experimental setup to detect four distinct spectral passbands. (C) 2010 Optical Society of America
引用
收藏
页码:4067 / 4076
页数:10
相关论文
共 50 条
  • [31] IMAGING White-light diffraction tomography
    Bouwens, Arno
    Lasser, Theo
    NATURE PHOTONICS, 2014, 8 (03) : 173 - 174
  • [32] OPTICAL-IMAGE SUBTRACTION USING A LCTV SLM AND WHITE-LIGHT IMAGING GRATING INTERFEROMETER
    CAI, LZ
    CHAO, TH
    JOURNAL OF MODERN OPTICS, 1990, 37 (06) : 1127 - 1138
  • [33] Spectral anomalies due to temporal correlation in a white-light interferometer
    Brundavanam, Maruthi M.
    Viswanathan, Nirmal K.
    Desai, Narayana Rao
    OPTICS LETTERS, 2007, 32 (16) : 2279 - 2281
  • [34] Nanorelief Measurements Errors for a White-Light Interferometer with Chromatic Aberrations
    Sysoev, Evgeny V.
    MEASUREMENT TECHNOLOGY AND INTELLIGENT INSTRUMENTS IX, 2010, 437 : 51 - 55
  • [35] Self-calibrating lateral scanning white-light interferometer
    Munteanu, Florin
    APPLIED OPTICS, 2010, 49 (12) : 2371 - 2375
  • [36] A white-light Michelson interferometer in the visible and near infrared regions
    Fuji, T
    Arakawa, M
    Hattori, T
    Nakatsuka, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (08): : 2854 - 2858
  • [37] ADJUSTMENT OF MACH-ZEHNDER INTERFEROMETER FOR WHITE-LIGHT FRINGES
    CLARK, RJ
    HAUSE, CD
    BENNETT, GS
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1953, 43 (05) : 408 - 409
  • [38] WHITE-LIGHT INTERFEROMETER FOR REAL-TIME PHASE PSEUDOCOLORING
    TORROBA, RD
    ARIZAGA, R
    OPTICS COMMUNICATIONS, 1987, 64 (03) : 221 - 223
  • [39] Measurement of group delay of dispersive mirrors with white-light interferometer
    Amotchkina, Tatiana V.
    Tikhonravov, Alexander V.
    Trubetskov, Michael K.
    Grupe, Dirk
    Apolonski, Alexander
    Pervak, Vladimir
    APPLIED OPTICS, 2009, 48 (05) : 949 - 956
  • [40] Dispersion optimized white-light interferometer based on a Schwarzschild objective
    Kuehnhold, Peter
    Lehmann, Peter
    Niehues, Jan
    OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION VII, 2011, 8082