The Amsterdam UMC protocol for computer-assisted mandibular and maxillary reconstruction; A cadaveric study

被引:1
|
作者
van Baar, Gustaaf J. C. [1 ,2 ]
Lodders, Johannes N. [1 ,2 ]
Chhangur, Chayenne [1 ,2 ]
Leeuwrik, Lars [1 ,2 ]
Forouzanfar, Tymour [1 ,2 ]
Liberton, Niels P. T. J. [3 ]
Berkhout, W. Erwin R. [4 ]
Winters, Henri A. H. [5 ]
Leusink, Frank K. J. [1 ,2 ]
机构
[1] Vrije Univ Amsterdam, Amsterdam UMC, Dept Oral & Maxillofacial Surg Pathol, Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Acad Ctr Dent Amsterdam ACTA, Amsterdam, Netherlands
[3] Vrije Univ Amsterdam, Dept Med Technol, 3D Innovat Lab, Amsterdam UMC, Amsterdam, Netherlands
[4] Acad Ctr Dent Amsterdam ACTA, Dept Oral & Maxillofacial Radiol, Amsterdam, Netherlands
[5] Vrije Univ Amsterdam, Dept Plast Reconstruct & Hand Surg, Amsterdam UMC, Amsterdam, Netherlands
关键词
Maxillofacial Reconstruction; Fibula Free Flap; Surgery; Computer-Assisted; Dental Implant; Cadaver; Accuracy; FIBULA-FREE FLAPS; QUALITY-OF-LIFE; VASCULARIZED FIBULA; REHABILITATION; ACCURACY; DEFECTS; SURGERY; HEAD; PLACEMENT; MORBIDITY;
D O I
10.1016/j.oraloncology.2022.106050
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objectives: In this cadaveric study, the accuracy of CAS guided mandibular and maxillary reconstruction including immediate dental implant placement in different Brown defect classes is assessed. Materials and methods: The virtual planning and surgical procedure was conducted according to a newly proposed Amsterdam UMC reconstruction protocol. Postoperative evaluation was performed according to a previously proposed evaluation guideline. Results: Fourteen mandibular and 6 maxillary reconstructions were performed. Average mandibular angle deviations were 1.52 degrees +/- 1.32, 1.85 degrees +/- 1.58, 1.37 degrees +/- 1.09, 1.78 degrees +/- 1.37, 2.43 degrees +/- 1.52 and 2.83 degrees +/- 2.37, respectively for the left and right axial angles, left and right coronal angles and left and right sagittal angles. A total of 62 dental implants were placed in neomandibles with an average dXYZ values of 3.68 +/- 2.21 mm and 16 in neomaxillas with an average dXYZ values of 3.24 +/- 1.7 mm. Conclusion: Promising levels of accuracy were achieved for all mandibular angles. Dental implant positions approached the preoperative preferred positions well, within the margin to manufacture prosthetic devices.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Computer-assisted system on mandibular canal detection
    Cheng, Da-Chuan
    Chen, Li-Wei
    Shen, Yen-Wen
    Fuh, Lih-Jyh
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2017, 62 (06): : 575 - 580
  • [22] Evaluation of computer-assisted mandibular reconstruction with vascularized fibular flap compared to conventional surgery
    Zhang, Lei
    Liu, Zhixu
    Li, Biao
    Yu, Hongbo
    Shen, Steve Guofang
    Wang, Xudong
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2016, 121 (02): : 139 - 148
  • [23] Evaluation of accuracy and sensory outcomes of mandibular reconstruction using computer-assisted surgical simulation
    Zhou, Zhihang
    Zhao, Haoming
    Zhang, Shanyong
    Zheng, Jisi
    Yang, Chi
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2019, 47 (01) : 6 - 14
  • [24] Fibular osteofasciocutaneous flap in computer-assisted mandibular reconstruction: technical aspects in oral malignancies
    Berrone, M.
    Crosetti, E.
    Tos, P. L.
    Pentenero, M.
    Succo, G.
    ACTA OTORHINOLARYNGOLOGICA ITALICA, 2016, 36 (06) : 469 - 478
  • [25] Computer-assisted versus traditional freehand technique in fibular free flap mandibular reconstruction: a morphological comparative study
    Thibault De Maesschalck
    Delphine S. Courvoisier
    Paolo Scolozzi
    European Archives of Oto-Rhino-Laryngology, 2017, 274 : 517 - 526
  • [26] Computer-assisted versus traditional freehand technique in fibular free flap mandibular reconstruction: a morphological comparative study
    Maesschalck, Thibault De
    Courvoisier, Delphine S.
    Scolozzi, Paolo
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2017, 274 (01) : 517 - 526
  • [27] Computer-assisted versus traditional technique in fibular free-flap mandibular reconstruction: A CT symmetry study
    Bartier, S.
    Mazzaschi, O.
    Benichou, L.
    Sauvaget, E.
    EUROPEAN ANNALS OF OTORHINOLARYNGOLOGY-HEAD AND NECK DISEASES, 2021, 138 (01) : 23 - 27
  • [28] Computer-Assisted Navigation for Dorsal Percutaneous Scaphoid Screw Placement: A Cadaveric Study
    Kam, Check C.
    Greenberg, Jeffrey A.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (04): : 613 - 620
  • [29] Computer-assisted orbital floor reconstruction
    Kuehnel, T. V.
    Vairaktaris, E.
    Alexiou, C.
    Schlegel, K. A.
    Neukam, F. W.
    Nkenke, E.
    HNO, 2008, 56 (11) : 1142 - 1147
  • [30] Computer-assisted temporomandibular joint reconstruction
    Zwetyenga, N.
    Mommers, X. -A.
    Cheynet, F.
    REVUE DE STOMATOLOGIE DE CHIRURGIE MAXILLO-FACIALE ET DE CHIRURGIE ORALE, 2013, 114 (04) : 255 - 262