Comparison between a screen-film system and a selenium radiography system - An ROC study using simulated thoracic lesions

被引:5
|
作者
Kotter, E [1 ]
Einert, A [1 ]
Merz, C [1 ]
Allmann, KH [1 ]
Altehoefer, C [1 ]
Ghanem, N [1 ]
Langer, M [1 ]
机构
[1] Freiburg Univ Hosp, Dept Diagnost Radiol, D-79106 Freiburg, Germany
关键词
phantoms; radiography; digital; technology; receiver operating characteristics curve; thorax;
D O I
10.1097/00004424-199904000-00007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. TO evaluate the diagnostic image quality of the hard copies of a commercially available selenium detector-based computed radiography system compared to that of a conventional screen-film system, METHODS. Ten radiographs of an anthropomorphic chest phantom with simulated nodular and linear-reticular lesions were produced using either system, Each radiograph was sub-divided into 15 fields containing zero lesions, one nodular lesion, one linear-reticular lesion, or both lesions, The total or 150 Gelds for each modality was reviewed by six radiologists, and receiver operating analysis was performed, RESULTS. The conventional screen-film system performed significantly better for nodular lesions, whereas no statistically significant difference was found between the detection rates of both systems for linear-reticular lesions, CONCLUSIONS. The better detection of nodules with the dedicated selenium detector can be explained by the higher dynamic range of the system, Detection of linear-reticular lesions was slightly but not significantly better with the screen-film system, but the detection rate of the selenium detector might be further improved with a different image processing technique.
引用
收藏
页码:296 / 302
页数:7
相关论文
共 50 条
  • [21] CLINICAL-TESTING OF THE ULTRA-VISION SCREEN-FILM SYSTEM FOR MAXILLOFACIAL RADIOGRAPHY
    SEWERIN, IP
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1994, 77 (03): : 302 - 307
  • [22] Performance comparison of an active matrix flat panel imager, computed radiography system, and a screen-film system at four standard radiation qualities
    Monnin, P
    Gutierrez, D
    Bulling, S
    Lepori, D
    Valley, JF
    Verdun, FR
    MEDICAL PHYSICS, 2005, 32 (02) : 343 - 350
  • [23] Screening Mammography Efficacy: A Comparison Between Screen-Film, Computed Radiography and Digital Mammography in Taiwan
    Elbakkoush, Abdallah Ahmed
    Atique, Suleman
    Chiang, I-Jen
    MEDINFO 2015: EHEALTH-ENABLED HEALTH, 2015, 216 : 914 - 914
  • [24] Performance of a new digital flat-panel detector system in the detection of simulated rheumathoid erosions: A comparison with a speed class 200 screen-film system, a mammography screen-film system and a storage-phosphor system at different levels of exposure
    Ludwig, K
    Henschel, A
    Bernhardt, T
    Lenzen, H
    Wormanns, D
    Diederich, S
    Heindel, W
    MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 423 - 426
  • [25] X-RAY EXAMINATIONS OF PERIPHERAL JOINTS - COMPARISON OF DIGITAL LUMINESCENT RADIOGRAPHY (DLR) AND SCREEN-FILM SYSTEM COMBINATIONS
    KRUG, B
    FISCHBACH, R
    HERRMANN, S
    DIETLEIN, M
    KUPPER, T
    DOLKEN, W
    HARNISCHMACHER, U
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1993, 158 (02): : 133 - 140
  • [26] URORADIOGRAPHIC DOSIMETRY USING A RARE-EARTH SCREEN-FILM SYSTEM
    SEGAL, AJ
    MAILLIE, HD
    LEMKIN, JA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 139 (05) : 923 - 926
  • [27] Interpretation of normal anatomic structures on chest radiography: Comparison of Fuji computed radiography (FCR) 5501D with FCR 5000 and screen-film system
    Nakashima, K
    Ashizawa, K
    Ochi, M
    Goto, S
    Igarashi, A
    Hayashi, K
    RADIOLOGY, 2001, 221 : 160 - 161
  • [28] BARIUM ENEMA CARRIED OUT BY DIGITAL LUMINESCENT RADIOGRAPHY (DLR) AND CONVENTIONAL SCREEN-FILM SYSTEM COMBINATIONS
    KRUG, B
    STEINBRICH, W
    LORENZ, R
    GLATHE, S
    DIETLEIN, M
    SCHIRRMEISTER, J
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1990, 152 (02): : 131 - 136
  • [29] COMPARISON OF IMAGING PROPERTIES OF A COMPUTED RADIOGRAPHY SYSTEM AND SCREEN FILM SYSTEMS
    SANADA, S
    DOI, K
    XU, XW
    YIN, FF
    GIGER, ML
    MACMAHON, H
    MEDICAL PHYSICS, 1991, 18 (03) : 414 - 420
  • [30] Contrast-detail comparison of a full-field digital mammography system and a screen-film system
    Rosol, MS
    Niklason, LT
    Venkatakrishnan, V
    Silvenoinnen, H
    Kopans, DB
    Hamberg, LM
    RADIOLOGY, 1999, 213P : 151 - 151