Improved performance lead iodide nuclear radiation detectors

被引:61
|
作者
Deich, V [1 ]
Roth, M [1 ]
机构
[1] HEBREW UNIV JERUSALEM,SCH APPL SCI,IL-91904 JERUSALEM,ISRAEL
关键词
D O I
10.1016/S0168-9002(96)00303-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Melt-grown lead iodide single crystals with an improved transport of positive charge carriers (holes) have been developed. It is shown that an energy resolution of about 3% can be obtained for gamma-radiation at 60 keV (Am-241 isotope source). Improvement of the spectrometric performance of lead iodide detectors at lower gamma-ray energies has been achieved as well due to better purification of the starting material and optimization of the etching procedure. Correlation between the detector performance and the structure of lead iodide crystals has been studied using X-ray diffraction analysis.
引用
收藏
页码:169 / 172
页数:4
相关论文
共 50 条
  • [41] Improved performance of GaAs radiation detectors with low temperature ohmic contacts
    Nava, F
    Bertuccio, G
    Vanni, P
    Canali, C
    Cavallini, A
    Castaldini, A
    Polenta, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) : 943 - 949
  • [42] STATE-OF-ART OF CRYSTAL-GROWTH AND NUCLEAR SPECTROSCOPIC EVALUATION OF MERCURIC IODIDE RADIATION DETECTORS
    SCHIEBER, M
    BEINGLASS, I
    DISHON, G
    HOLZER, A
    YARON, G
    NUCLEAR INSTRUMENTS & METHODS, 1978, 150 (01): : 71 - 77
  • [43] ELECTRONIC NOISE IN LEAD IODIDE X-RAY-DETECTORS
    SHAH, KS
    LUND, JC
    OLSCHNER, F
    BENNETT, P
    ZHANG, J
    MOY, LP
    SQUILLANTE, MR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3): : 85 - 88
  • [44] Growth of lead iodide single crystals used for nuclear radiation detection of Gamma-rays
    Liu, Jing
    Zhang, Yu
    CRYSTAL RESEARCH AND TECHNOLOGY, 2017, 52 (03)
  • [45] Current instability and polarization phenomena in lead iodide crystalline detectors
    Ponpon, JP
    Amann, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 526 (03): : 447 - 454
  • [46] Fabrication and performance of mercuric iodide pixellated detectors
    van den Berg, Lodewijk
    Bastian, Lloyd F.
    Zhang, Feng
    Lenos, Howard
    Capote, M. Albert
    HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS IX, 2007, 6706
  • [47] CADMIUM TELLURIDE NUCLEAR RADIATION DETECTORS
    SIFFERT, P
    CORNET, A
    STUCK, R
    TRIBOULET, R
    MARFAING, Y
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1975, NS22 (01) : 211 - 225
  • [48] ROLE OF CONTACTS TO NUCLEAR RADIATION DETECTORS
    TOVE, PA
    NUCLEAR INSTRUMENTS & METHODS, 1976, 133 (03): : 445 - 452
  • [49] Avalanche heterodiodes as detectors of nuclear radiation
    Burbaev, T.M.
    Kalyuzhnaya, G.A.
    Kashevarov, N.L.
    Kravchenko, V.V.
    Kurbatov, V.A.
    Mironov, N.I.
    Osina, T.I.
    Pavlychenko, L.N.
    Sokol, G.A.
    Starodubtsev, N.F.
    Shubin, V.E.
    Sbornik - Kratkie Soobshcheniya po Fizike AN SSSR, 1992, (3-4): : 34 - 38
  • [50] Cadmium telluride detectors for nuclear radiation
    Tkachuk, PN
    Tkachuk, VI
    Plyuta, DI
    Raranskii, AN
    INORGANIC MATERIALS, 1996, 32 (11) : 1184 - 1186