Evaluation of a Low-Fidelity Surgical Simulator for Large Loop Excision of the Transformation Zone (LLETZ)

被引:6
|
作者
Wilson, Erin B. [1 ]
Beckmann, Michael M. [2 ,3 ,4 ]
Hewett, David G. [4 ,5 ]
Jolly, Brian C. [6 ]
Janssens, Sarah [4 ,7 ]
机构
[1] Univ Queensland, Sch Med, Mater Res, Brisbane, Qld, Australia
[2] Univ Queensland, Sch Med, Mothers Babies & Womens Hlth Serv, Brisbane, Qld, Australia
[3] Univ Queensland, Sch Med, Mater Hlth Serv, South Brisbane Mater Res, Brisbane, Qld, Australia
[4] Univ Queensland, Sch Med, Brisbane, Qld, Australia
[5] Queen Elizabeth II Jubilee Hosp, Brisbane, Qld, Australia
[6] Univ Newcastle, Sch Med & Publ Hlth, Callaghan, NSW, Australia
[7] Mater Hlth Serv, South Brisbane, Qld, Australia
关键词
Simulator development; validation; gynecology; OBJECTIVE STRUCTURED ASSESSMENT; SKILLS; VALIDITY; VALIDATION; CURRICULUM; RESIDENTS; OUTCOMES; TRAINER; MODEL; OSATS;
D O I
10.1097/SIH.0000000000000242
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Introduction: Large loop excision of the transformation zone (LLETZ) is a common gynecological treatment for cervical dysplasia but can be challenging to teach. There is no widely adopted simulator for this procedure in Australia, so a new low-fidelity simulator was designed and evaluated. Method: A simulator for a LLETZ procedure was developed. Doctors (N = 29), varied in experience level in gynecology at a tertiary hospital, performed a LLETZ procedure using the simulator. The procedures were filmed, and two independent assessors rated the deidentified videos. The assessment involved a checklist (of crucial procedural steps) and global rating scale to evaluate whether the simulator facilitated the demonstration of LLETZ procedure skills. Participants completed a questionnaire evaluating the performance and utility of the simulator to determine participant perceptions of simulator realism and acceptability. Results: The participant questionnaire revealed positive evaluations of realism and acceptability of the simulator. Performance scores were significantly different across experience levels (P < 0.001) with post hoc pairwise comparison between levels confirming significant differences between each group in assessed simulator performance for global rating scale and overall performance scores. The interrater reliability of the assessors was high (0.84). Conclusions: A low-fidelity simulator for a LLETZ procedure seems to adequately demonstrate procedural performance reflecting doctor experience level. Participant questionnaire responses were positive, supporting further evaluation of the simulator for use in training.
引用
收藏
页码:304 / 307
页数:4
相关论文
共 50 条
  • [41] HISTOLOGICAL INCOMPLETE EXCISION OF CIN AFTER LARGE LOOP EXCISION OF THE TRANSFORMATION ZONE (LLETZ) MERITS CAREFUL FOLLOW-UP, NOT RETREATMENT - REPLY
    MONAGHAN, JM
    LOPES, A
    ROBERTSON, G
    BEYNON, DWG
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1993, 100 (08): : 795 - 795
  • [42] Large loop excision of the transformation zone: An outpatient procedure
    Gazvani, M.R.
    Öztürk, O.
    Turkish Journal of Medical Sciences, 2001, 31 (05) : 435 - 438
  • [43] PREGNANCY FOLLOWING LARGE LOOP EXCISION OF THE TRANSFORMATION ZONE
    HAFFENDEN, DK
    BIGRIGG, A
    CODLING, BW
    READ, MD
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1993, 100 (11): : 1059 - 1060
  • [44] Introducing a novel model for simulating large loop excision of the transformation zone (LLETZ) using 3D printing technique
    Kiesel, Matthias
    Beyers, Inga
    Kalisz, Adam
    Woeckel, Achim
    Herbert, Saskia-Laureen
    Curtaz, Carolin
    Diessner, Joachim
    Joukhadar, Ralf
    Wulff, Christine
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2022, 305 (03) : 703 - 712
  • [45] Introducing a novel model for simulating large loop excision of the transformation zone (LLETZ) using 3D printing technique
    Matthias Kiesel
    Inga Beyers
    Adam Kalisz
    Achim Wöckel
    Saskia-Laureen Herbert
    Carolin Curtaz
    Joachim Diessner
    Ralf Joukhadar
    Christine Wulff
    Archives of Gynecology and Obstetrics, 2022, 305 : 703 - 712
  • [46] LARGE LOOP EXCISION OF THE TRANSFORMATION ZONE (LLETZ) COMPARED TO CARBON-DIOXIDE LASER IN THE TREATMENT OF CIN - A SUPERIOR MODE OF TREATMENT
    GUNASEKERA, PC
    PHIPPS, JH
    LEWIS, BV
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1990, 97 (11): : 995 - 998
  • [47] LLETZ make it simple: Anxiety, pain and treatment outcomes with outpatient large loop excision of the transformation zone under local anaesthesia
    Yap, Shui-Jean
    Nathan, Elizabeth
    Farrell, Louise
    AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 2020, 60 (03): : 438 - 443
  • [48] LARGE LOOP EXCISION OF THE TRANSFORMATION ZONE (LLETZ) AS AN ALTERNATIVE TO BOTH LOCAL ABLATIVE AND CONE BIOPSY TREATMENT - A SERIES OF 1000 PATIENTS
    HALLAM, NF
    WEST, J
    HARPER, C
    EDWARDS, A
    HOPE, S
    MERRIMAN, H
    PANDHER, KS
    PINCHES, P
    SLADE, R
    MARSH, G
    CHARNOCK, M
    GRAY, W
    JOURNAL OF GYNECOLOGIC SURGERY, 1993, 9 (02) : 77 - 82
  • [49] Depth of glandular crypts and its involvement in squamous intraepithelial cervical neoplasia submitted to large loop excision of transformation zone (LLETZ)
    Okazaki, C.
    Focchi, G. R. A.
    Taha, N. S. A.
    Ahmeida, P. Q.
    Schimidt, M. A.
    Speck, N. M. G.
    Ribalta, J. C. L.
    EUROPEAN JOURNAL OF GYNAECOLOGICAL ONCOLOGY, 2013, 34 (01) : 48 - 50
  • [50] A prospective study of the correlation between Chlamydia trachomatis infection and secondary bleeding following large loop excision of the transformation zone (LLETZ)
    Arko, D
    Takac, I
    WIENER KLINISCHE WOCHENSCHRIFT, 2001, 113 : 11 - 13