Evaluation of a 4D Cone-Beam CT Reconstruction Approach using a Simulation Framework

被引:3
|
作者
Hartl, Alexander [1 ]
Yaniv, Ziv [1 ]
机构
[1] Georgetown Univ, Med Ctr, Imaging Sci & Informat Syst Ctr, Dept Radiol, Washington, DC 20007 USA
关键词
COMPUTED-TOMOGRAPHY; MOTION;
D O I
10.1109/IEMBS.2009.5333125
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Current image-guided navigation systems for thoracic abdominal interventions utilize three dimensional (3D) images acquired at breath-hold. As a result they can only provide guidance at a specific point in the respiratory cycle. The intervention is thus performed in a gated manner, with the physician advancing only when the patient is at the same respiratory cycle in which the 3D image was acquired. To enable a more continuous workflow we propose to use 4D image data. We describe an approach to constructing a set of 4D images from a diagnostic CT acquired at breath-hold and a set of intraoperative cone-beam CT (CBCT) projection images acquired while the patient is freely breathing. Our approach is based on an initial reconstruction of a gated 4D CBCT data set. The 3D CBCT images for each respiratory phase are then non-rigidly registered to the diagnostic CT data. Finally the diagnostic CT is deformed based on the registration results, providing a 4D data set with sufficient quality for navigation purposes. In this work we evaluate the proposed reconstruction approach using a simulation framework. A 3D CBCT dataset of an anthropomorphic phantom is deformed using internal motion data acquired from an animal model to create a ground truth 4D CBCT image. Simulated projection images are then created from the 4D image and the known CBCT scan parameters. Finally, the original 3D CBCT and the simulated X-ray images are used as input to our reconstruction method. The resulting 4D data set is then compared to the known ground truth by normalized cross correlation(NCC). We show that the deformed diagnostic CTs are of better quality than the gated reconstructions with a mean NCC value of 0.94 versus a mean 0.81 for the reconstructions.
引用
下载
收藏
页码:5729 / 5732
页数:4
相关论文
共 50 条
  • [41] Accuracy of 4D Cone Beam CT and 4D Fan Beam CT for Thoracic Radiation Therapy Simulation and Verification Imaging
    Nyflot, M.
    Bowen, S. R.
    Lee, T.
    Meyer, J.
    Sandison, G. A.
    Kinahan, P. E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S640 - S640
  • [42] Adaptive 4D cone beam CT
    Lu, J.
    Zhu, R.
    Munro, P.
    Jeung, A.
    Mostafave, H.
    Chi, P.
    Balter, P.
    Guerrero, T.
    Mohan, R.
    Pan, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S609 - S609
  • [43] Simulation of EUV Imaging and 3-D Cone-Beam CT Reconstruction on the Plasmasphere
    Chen Z.
    Zheng J.
    Li L.
    Xu R.
    Jin X.
    Huang Y.
    Tsinghua Science and Technology, 2010, 15 (01) : 127 - 132
  • [44] Simulation of EUV Imaging and 3-D Cone-Beam CT Reconstruction on the Plasmasphere
    陈志强
    郑杰
    李亮
    徐荣栏
    金鑫
    黄娅
    Tsinghua Science and Technology, 2010, 15 (01) : 127 - 132
  • [45] Dose Reconstruction for Lung Stereotactic Body Radiation Therapy (SBRT) Patients Using On-Board 4D Cone-Beam CT
    Huang, X.
    Zhang, Y.
    Wang, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E169 - E169
  • [46] Improved CT Reconstruction Resolution using Differential Cone-Beam CT Reconstruction
    Syahirah, Z.
    Zee, B.
    Liu, T.
    PROCEEDINGS OF THE 22ND INTERNATIONAL SYMPOSIUM ON THE PHYSICAL AND FAILURE ANALYSIS OF INTEGRATED CIRCUITS (IPFA 2015), 2015, : 520 - 523
  • [47] ScatterNet for 4D cone-beam CT intensity correction of lung cancer patients
    Schmitz, H.
    Lombardo, E.
    Kawula, M.
    Parodi, K.
    Belka, C.
    Kamp, F.
    Kurz, C.
    Landry, G.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S785 - S786
  • [48] Enhanced 4D cone-beam CT with inter-phase motion model
    Li, Tianfang
    Koong, Albert
    Xing, Lei
    MEDICAL PHYSICS, 2007, 34 (09) : 3688 - 3695
  • [49] A fast iteration approach to undersampled cone-beam CT reconstruction
    Zhu, Yechen
    Liu, Yangchuan
    Zhang, Qi
    Zhang, Cishen
    Gao, Xin
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2019, 27 (01) : 111 - 129
  • [50] Dosimetric Evaluation of DIR Mapped Contours for Image Guided Adaptive Radiotherapy with 4D Cone-Beam CT
    Balik, S.
    Weiss, E.
    Jan, N.
    Zhang, L.
    Roman, N.
    Christensen, G.
    Williamson, J.
    Hugo, G.
    MEDICAL PHYSICS, 2014, 41 (06) : 191 - 191