Slit device for FOCCoS - PFS - Subaru

被引:1
|
作者
de Oliveira, Antonio Cesar [1 ]
Gunn, James E. [2 ]
de Oliveira, Ligia Souza [3 ]
de Arruda, Marcio Vital [1 ]
Marrara, Lucas Souza [3 ]
dos Santos, Leandro Henrique [1 ]
Ferreira, Decio [1 ]
dos Santos, Jesulino Bispo [1 ]
Rosa, Josimar Aparecido [1 ]
Ribeiro, Flavio Felipe [1 ]
Vilaca, Rodrigo de Paiva [1 ]
Verducci Junior, Orlando [1 ]
Sodre Junior, Laerte [4 ]
de Oliveira, Claudia Mendes [4 ]
机构
[1] MCT LNA, Lab Nacl Astrofis, Itajuba, MG, Brazil
[2] Princeton Univ, Dept Astrophys Sci, Princeton, NJ 08544 USA
[3] OIO Oliveira Instrumentacao Opt LTDA, Sao Paulo, SP, Brazil
[4] Univ Sao Paulo, Inst Astron Geofis & Ciencias Atmosfer, IAG USP, Sao Paulo, SP, Brazil
关键词
Spectrograph; Optical Fibers; Slit device;
D O I
10.1117/12.2056400
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The Fiber Optical Cable and Connector System, "FOCCoS", subsystem of the Prime Focus Spectrograph, "PFS", for Subaru telescope, is responsible to feed four spectrographs with a set of optical fibers cables. The light injection for each spectrograph is assured by a convex curved slit with a linear array of 616 optical fibers. In this paper we present a design of a slit that ensures the right direction of the fibers by using masks of micro holes. This kind of mask is made by a technique called electroforming, which is able to produce a nickel plate with holes in a linear sequence. The precision error is around 1-mu m in the diameter and 1-mu m in the positions of the holes. This nickel plate may be produced with a thickness between 50 and 200 microns, so it may be very flexible. This flexibility allows the mask to be bent into the shape necessary for a curved slit. The concept requires two masks, which we call Front Mask, and Rear Mask, separated by a gap that defines the thickness of the slit. The pitch and the diameter of the holes define the linear geometry of the slit; the curvature of each mask defines the angular geometry of the slit. Obviously, this assembly must be mounted inside a structure rigid and strong enough to be supported inside the spectrograph. This structure must have a CTE optimized to avoid displacement of the fibers or increased FRD of the fibers when the device is submitted to temperatures around 3 degrees Celsius, the temperature of operation of the spectrograph. We have produced two models. Both are mounted inside a very compact Invar case, and both have their front surfaces covered by a dark composite, to reduce stray light. Furthermore, we have conducted experiments with two different internal structures to minimize effects caused by temperature gradients. This concept has several advantages relative to a design based on Vgrooves, which is the classical option. It is much easier and quicker to assemble, much cheaper, more accurate, easier to adjust; and it also offers the possibility of making a device much more strong, robust and completely miniaturized.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Prime Focus Spectrograph (PFS): A Very Wide-Field, Massively Multi-Object, Optical and Near-Infrared Fiber-Fed Spectrograph on the Subaru Telescope
    Tamura, Naoyuki
    MULTI-OBJECT SPECTROSCOPY IN THE NEXT DECADE: BIG QUESTIONS, LARGE SURVEYS, AND WIDE FIELDS, 2016, 507 : 387 - 391
  • [42] AN EXVIVO NARROW-SLIT FLOW DEVICE FOR EVALUATION OF BLOOD-MATERIAL INTERACTIONS
    WILSON, RS
    GOODE, MG
    LELAH, MD
    COOPER, SL
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1982, 28 : 420 - 425
  • [43] DEVICE FOR ELIMINATING CORNEAL LIGHT REFLECTIONS DURING RECORDING OF LATERAL IMAGES WITH A SLIT LAMP
    BOCCA, E
    FONDA, S
    VECCHI, D
    BARALDI, P
    DEGREGORIO, F
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1986, 224 (03) : 281 - 283
  • [44] Effect of the spectrometer slit width and charge-coupled device detector on Raman intensities
    Jakubek, Ryan S.
    JOURNAL OF RAMAN SPECTROSCOPY, 2021, 52 (07) : 1317 - 1333
  • [45] Clinical Observation of Allergic Conjunctival Diseases with Portable and Recordable Slit-Lamp Device
    Yazu, Hiroyuki
    Shimizu, Eisuke
    Sato, Shinri
    Aketa, Naohiko
    Katayama, Taiichiro
    Yokoiwa, Ryota
    Sato, Yasunori
    Fukagawa, Kazumi
    Ogawa, Yoko
    Tsubota, Kazuo
    Fujishima, Hiroshi
    DIAGNOSTICS, 2021, 11 (03)
  • [46] A STABLE SLIT LAMP MOUNTING DEVICE FOR 90 D LENS USE IN NONCONTACT OPHTHALMOSCOPY
    ROSENWASSER, GOD
    TIEDEMAN, JS
    OPHTHALMIC SURGERY AND LASERS, 1986, 17 (08): : 525 - 525
  • [47] An optimization design method for differential-based coupling power-slit device
    Yu, Xiangjun
    Wang, Jixin
    Yao, Mingyao
    Yao, Zongwei
    ADVANCES IN POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 614-615 : 1311 - +
  • [48] Infrared slit light-based scanning type portable device for monitoring of cataract
    Kaushik, Neelam
    Sasaki, Takashi
    Kamijo, Hiroyuki
    Nakazawa, Toru
    Hane, Kazuhiro
    OPTICAL ENGINEERING, 2022, 61 (03)
  • [49] PORTABLE OPHTHALMIC DEVICE FOR REMOTE SLIT-LAMP EXAMINATIONS AND VISUAL ACUITY SCREENING
    Phan, Alex
    Truong, Buu
    Suen, Benjamin
    Melles, Gerrit
    Talke, Frank E.
    PROCEEDINGS OF THE ASME 2021 30TH CONFERENCE ON INFORMATION STORAGE AND PROCESSING SYSTEMS (ISPS2021), 2021,
  • [50] Sorting of circulating tumor cells based on the microfluidic device of a biomimetic splenic interendothelial slit array
    Jianfeng Chen
    Zefan Yang
    Wenhu Xu
    Meirong Yi
    Min Zhong
    Xiaobing Li
    Hongwei Tian
    Microfluidics and Nanofluidics, 2021, 25