Modeling and Control of a Cable-Driven Rotary Series Elastic Actuator for an Upper Limb Rehabilitation Robot

被引:25
|
作者
Zhang, Qiang [1 ,2 ]
Sun, Dingyang [1 ]
Qian, Wei [1 ]
Xiao, Xiaohui [1 ,3 ]
Guo, Zhao [1 ,3 ]
机构
[1] Wuhan Univ, Sch Power & Mech Engn, Wuhan, Peoples R China
[2] NC State Univ, UNC NCSU Joint Dept Biomed Engn, Raleigh, NC USA
[3] Wuhan Univ Shenzhen Res Inst, Shenzhen, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
series elastic actuator (SEA); rehabilitation robot; bowden cable; torque control; impedance control; disturbance observer (DOB); IMPEDANCE CONTROL; DESIGN; EXOSKELETON;
D O I
10.3389/fnbot.2020.00013
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
This paper focuses on the design, modeling, and control of a novel remote actuation, including a compact rotary series elastic actuator (SEA) and Bowden cable. This kind of remote actuation is used for an upper limb rehabilitation robot (ULRR) with four powered degrees of freedom (DOFs). The SEA mainly consists of a DC motor with planetary gearheads, inner/outer sleeves, and eight linearly translational springs. The key innovations include (1) an encoder for direct spring displacement measurement, which can be used to calculate the output torque of SEA equivalently, (2) the embedded springs can absorb the negative impact of backlash on SEA control performance, (3) and the Bowden cable enables long-distance actuation and reduces the bulky structure on the robotic joint. In modeling of this actuation, the SEA's stiffness coefficient, the dynamics of the SEA, and the force transmission of the Bowden cable are considered for computing the inputs on each powered joint of the robot. Then, both torque and impedance controllers consisting of proportional-derivative (PD) feedback, disturbance observer (DOB), and feedforward compensation terms are developed. Simulation and experimental results verify the performance of these controllers. The preliminary results show that this new kind of actuation can not only implement stable and friendly actuation over a long distance but also be customized to meet the requirements of other robotic system design.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Wrench FeasibilityWorkspace Analysis and Adaptive Rotation Algorithm of Cable-Driven Upper Limb Rehabilitation Robot
    Li, Ye
    Song, Aiguo
    Lai, Jianwei
    Li, Huijun
    Shi, Ke
    PROCEEDINGS OF 2023 9TH INTERNATIONAL CONFERENCE ON ROBOTICS AND ARTIFICIAL INTELLIGENCE, ICRAI 2023, 2023, : 32 - 37
  • [32] A Cable-Driven Upper Limb Rehabilitation Robot With Muscle-Synergy-Based Myoelectric Controller
    Xie, Chenglin
    Lyu, Yueling
    Li, Guoxin
    Tong, Raymond Kai-Yu
    Xia, Haisheng
    Song, Rong
    Li, Zhijun
    IEEE TRANSACTIONS ON ROBOTICS, 2024, 40 : 3199 - 3211
  • [33] Research on a new cable-driven lower limb rehabilitation robot with bilateral coordination control
    Wang, Yanzhuo
    Wang, Lan
    Wang, Keyi
    Mo, Zongjun
    Li, Jinghang
    Yi, Liu
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2024, 238 (14) : 7143 - 7154
  • [34] Impedance Control of A Cable-Driven Series Elastic Actuator with the 2-DOF Control Structure
    Zou, Wulin
    Yang, Zhuo
    Tan, Wen
    Wang, Meng
    Liu, Jingtai
    Yu, Ningbo
    2016 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS 2016), 2016, : 3347 - 3352
  • [35] Control of Cable-Driven Parallel Robot for Gait Rehabilitation
    Gharatappeh, Soheil
    Abbasnejad, Ghasem
    Yoon, Jungwon
    Lee, Hosu
    2015 12TH INTERNATIONAL CONFERENCE ON UBIQUITOUS ROBOTS AND AMBIENT INTELLIGENCE (URAI), 2015, : 377 - 381
  • [36] Design Optimization and Dynamic Control of a 3-d.OF Planar Cable-Driven Parallel Robot for Upper Limb Rehabilitation
    Ennaiem, Ferdaws
    El Golli, Hanen
    Chaker, Abdelbadia
    Laribi, Med Amine
    Sandoval, Juan
    Bennour, Sami
    Mlika, Abdelfattah
    Romdhane, Lotfi
    Zeghloul, Said
    NEW TRENDS IN MEDICAL AND SERVICE ROBOTICS, 2022, 106 : 27 - 37
  • [37] Admittance control of a 3-DOF cable-driven rehabilitation robot for upper-limb in three dimensional workspace
    Yang, Qianqian
    Niu, Jie
    Song, Rong
    2017 2ND INTERNATIONAL CONFERENCE ON ADVANCED ROBOTICS AND MECHATRONICS (ICARM), 2017, : 445 - 449
  • [38] An Electromyographic-Based Control Using Gaussian Mixture Model on an Upper-Limb Cable-Driven Rehabilitation Robot
    Zheng, Jianlin
    Li, Zhijun
    Xu, Ting
    Song, Rong
    ADVANCED INTELLIGENT SYSTEMS, 2024,
  • [39] Human-Robot Interaction Force Control of Series Elastic Actuator-Driven Upper Limb Exoskeleton Robot
    Sun, Zhongbo
    Xu, Changxian
    Jin, Long
    Pang, Zaixiang
    Yu, Junzhi
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2024,
  • [40] Design and analysis of movable cable-driven lower limb rehabilitation robot
    Zou Y.
    Wang N.
    Liu K.
    Geng X.
    Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2019, 47 (01): : 22 - 26and38