Energy consumption modelling of a passive hybrid system for office buildings in different climates

被引:29
|
作者
Zhang, Yi [1 ]
Tennakoon, Thilhara [1 ]
Chan, Yin Hoi [1 ]
Chan, Ka Chung [1 ]
Fu, Sau Chung [1 ]
Tso, Chi Yan [2 ]
Yu, Kin Man [3 ]
Huang, Bao Ling [4 ]
Yao, Shu Huai [4 ]
Qiu, Hui He [4 ]
Chao, Christopher Y. H. [1 ]
机构
[1] Univ Hong Kong, Dept Mech Engn, Pokfulam, Hong Kong, Peoples R China
[2] City Univ Hong Kong, Sch Energy & Environm, Kowloon, Tat Chee Ave, Hong Kong, Peoples R China
[3] City Univ Hong Kong, Dept Phys, Kowloon, Tat Chee Ave, Hong Kong, Peoples R China
[4] Hong Kong Univ Sci & Technol, Dept Mech & Aerosp Engn, Kowloon, Clear Water Bay, Hong Kong, Peoples R China
关键词
Energy simulation; Green building; Thermochromic smart window; Passive radiative cooler; Passive cooling; PHOTONIC STRUCTURES; PERFORMANCE; CRYSTAL;
D O I
10.1016/j.energy.2021.121914
中图分类号
O414.1 [热力学];
学科分类号
摘要
Thermochromic smart windows and radiative coolers are two passive cooling technologies, whose adoption as windows and roofs, respectively, is feasible for building energy-saving. However, to the authors' knowledge, the investigation of annual energy performance incorporating both techniques is scarce at the time of writing. Therefore, a passive hybrid system involving both technologies is proposed in this study. A perovskite thermochromic smart window and three different radiative coolers were chosen based on their superior performance. The energy performance of the passive hybrid system in a prototypical medium-sized office building was simulated using EnergyPlus and the results were rigorously analyzed. Both thermochromic smart window and radiative cooler could reduce total energy consumptions by up to 10.6% and 23.0%, respectively, regardless of building's year of completion, while the synergic system saved up to 32.0%. Among the chosen cities of various climates, thermochromic smart windows and radiative coolers perform better in cities where cooling demand dominates. The west-and east-facing thermochromic smart windows could mitigate more energy usage in contrast to the other orientations. If this passive hybrid system can be offered at a reasonable cost, the technology is likely to be a viable energy-efficient option for buildings. (c) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Tropical climates and the interplay between IEQ and energy consumption in buildings: A review
    Verma, Ashutosh
    Gupta, Vallary
    Nihar, Kopal
    Jana, Arnab
    Jain, Rishee K.
    Deb, Chirag
    BUILDING AND ENVIRONMENT, 2023, 242
  • [42] Selection of passive energy consumption optimisation strategies for buildings
    Balali, Amirhossein
    Yunusa-Kaltungo, Akilu
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2025, 210
  • [43] The effects of climate change on heating energy consumption of office buildings in different climate zones in China
    Fanchao Meng
    Mingcai Li
    Jingfu Cao
    Ji Li
    Mingming Xiong
    Xiaomei Feng
    Guoyu Ren
    Theoretical and Applied Climatology, 2018, 133 : 521 - 530
  • [44] The effects of climate change on heating energy consumption of office buildings in different climate zones in China
    Meng, Fanchao
    Li, Mingcai
    Cao, Jingfu
    Li, Ji
    Xiong, Mingming
    Feng, Xiaomei
    Ren, Guoyu
    THEORETICAL AND APPLIED CLIMATOLOGY, 2018, 133 (1-2) : 521 - 530
  • [45] Climate change impacts on extreme energy consumption of office buildings in different climate zones of China
    Li, Mingcai
    Shi, Jun
    Cao, Jingfu
    Fang, Xiaoyi
    Wang, Min
    Wang, Xin
    THEORETICAL AND APPLIED CLIMATOLOGY, 2020, 140 (3-4) : 1291 - 1298
  • [46] A passive solar system for thermal comfort conditioning of buildings in composite climates
    Raman, P
    Mande, S
    Kishore, VVN
    SOLAR ENERGY, 2001, 70 (04) : 319 - 329
  • [47] Life Cycle Assessment of an Innovative Hybrid Energy Storage System for Residential Buildings in Continental Climates
    Llantoy, Noelia
    Zsembinszki, Gabriel
    Palomba, Valeria
    Frazzica, Andrea
    Dallapiccola, Mattia
    Trentin, Federico
    Cabeza, Luisa F.
    APPLIED SCIENCES-BASEL, 2021, 11 (09):
  • [48] Reduction of energy consumption using passive architecture in hot and humid climates
    Hazbei, Morteza
    Nematollahi, Omid
    Behnia, Mohsen
    Adib, Zahra
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2015, 47 : 16 - 27
  • [49] Passive retrofitting of office buildings to improve their energy performance and indoor environment: the OFFICE project
    Santamouris, M
    Dascalaki, E
    BUILDING AND ENVIRONMENT, 2002, 37 (06) : 575 - 578
  • [50] TOOL FOR HOURLY ENERGY CONSUMPTION ESTIMATION IN EXISTING OFFICE BUILDINGS
    Fumo, Nelson
    Mago, Pedro J.
    Ledbury, Emily
    ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2014, VOL 6B, 2015,