Efficacy of regional saturation of oxygen monitor using near-infrared spectroscopy for lower limb ischemia during minimally invasive cardiac surgery

被引:11
|
作者
Toya, Teppei [1 ]
Fujita, Tomoyuki [1 ]
Fukushima, Satuki [1 ]
Shimahara, Yusuke [1 ]
Kume, Yuta [1 ]
Yamashita, Kizuku [1 ]
Matsumoto, Yorihiko [1 ]
Kawamoto, Naonori [1 ]
Kobayashi, Junjiro [1 ]
机构
[1] Natl Cerebral & Cardiovasc Ctr, Dept Cardiac Surg, 5-7-1 Fujishirodai, Suita, Osaka 5658565, Japan
关键词
Near-infrared spectroscopy; Regional saturation of oxygen; Minimally invasive cardiac surgery; Lower limb ischemia; EXTRACORPOREAL MEMBRANE-OXYGENATION; RESOLVED SPECTROSCOPY; CONTINUOUS-WAVE; CANNULATION;
D O I
10.1007/s10047-018-1057-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Lower limb ischemia with an occlusive cannula is a potential complication of minimally invasive cardiac surgery (MICS). We evaluated intraoperative local oxygen supply-demand balance by monitoring regional saturation of oxygen (rSO(2)) using near-infrared spectroscopy (NIRS), and analyzed the correlation between cannula size and fluctuation range of rSO(2). Fifty-four patients undergoing MICS surgery using femoral artery cannulation from April 2015 to August 2016 were enrolled. The rSO(2) of both the cannulated and uncannulated lower limbs were measured using NIRS. The association between the decline of rSO(2) from baseline (delta-rSO(2)) and the ratio of the cannula diameter to the femoral artery diameter (Cd/FAd) was analyzed. Of the 54 patients, 16 (30%) (Group 1) showed values over 0.65 for Cd/FAd, and the remaining 38 (70%) (Group 2) showed values under 0.65. No patient developed postoperative lower limb ischemia. No patient was treated with an ipsilateral distal perfusion cannula. There were significant differences between Group 1 and Group 2 in the decrease of rSO(2) at the point of cannulation on the cannulated limb. In the lower limb on the cannulated side, delta-rSO(2) showed a significant decrease in Group 1 compared to Group 2 (Group 1 vs Group 2: 19.9 vs 11.0%; p<0.001). Delta-rSO(2) was significantly correlated with body surface aera (BSA), but not with gender or age. Decreasing rSO(2) correlates with the Cd/FAd index. Low BSA, Cd/Fad>0.65 is considered as the risk factor for decline of rSO(2) in cannulated limb in MICS.
引用
收藏
页码:420 / 426
页数:7
相关论文
共 50 条
  • [41] Near-infrared spectroscopy measurement of regional tissue oxyhemoglobin saturation during hemorrhagic shock
    Beilman, GJ
    Groehler, KE
    Lazaron, V
    Ortner, JP
    SHOCK, 1999, 12 (03): : 196 - 200
  • [42] Regional Cerebral oxygen saturation during electroconvulsive therapy: Monitoring by near-infrared spectrophotometry
    Saito, S
    Miyoshi, S
    Yoshikawa, D
    Shimada, H
    Morita, T
    Kitani, Y
    ANESTHESIA AND ANALGESIA, 1996, 83 (04): : 726 - 730
  • [43] Regional tissue oxygen saturation measured by near-infrared spectroscopy to assess the depth of burn injuries
    Seki, Tadahiko
    Fujioka, Masayuki
    Fukushima, Hidetada
    Matsumori, Hiroaki
    Maegawa, Naoki
    Norimoto, Kazunobu
    Okuchi, Kazuo
    INTERNATIONAL JOURNAL OF BURNS AND TRAUMA, 2014, 4 (01): : 40 - 44
  • [44] Monitoring regional cerebral oxygen saturation using near-infrared spectroscopy during pulsatile hypothermic cardiopulmonary bypass in a neonatal piglet model
    Ündar, A
    Eichstaedt, HC
    Frazier, OH
    Fraser, CD
    ASAIO JOURNAL, 2000, 46 (01) : 103 - 106
  • [45] Comparing near-infrared spectroscopy devices and their sensors for monitoring regional cerebral oxygen saturation in the neonate
    Laura M.L. Dix
    Frank van Bel
    Wim Baerts
    Petra M.A. Lemmers
    Pediatric Research, 2013, 74 : 557 - 563
  • [46] Comparing near-infrared spectroscopy devices and their sensors for monitoring regional cerebral oxygen saturation in the neonate
    Dix, Laura M. L.
    van Bel, Frank
    Baerts, Wim
    Lemmers, Petra M. A.
    PEDIATRIC RESEARCH, 2013, 74 (05) : 557 - 563
  • [47] Tissue oxygen index - Thresholds for cerebral ischemia using near-infrared spectroscopy
    Al-Rawi, Pippa G.
    Kirkpatrick, Peter J.
    STROKE, 2006, 37 (11) : 2720 - 2725
  • [48] Near-Infrared Spectroscopy During Reactive Hyperemia for the Assessment of Lower Limb Vascular Function
    Kriel, Yuri
    Kwintowski, Andrzej
    Feka, Krist
    Windsor, Mark
    Young, Grace
    Walker, Meegan
    Askew, Christopher D.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2024, (205):
  • [49] In vivo measurements of regional hemoglobin oxygen saturation values and limb-to-arm ratios of near-infrared spectroscopy for tissue oxygenation monitoring of lower extremities in healthy subjects
    Boezeman, Reinout P. E.
    Kelder, Johannes C.
    Waanders, Frans G. J.
    Moll, Frans L.
    de Vries, Jean-Paul P. M.
    MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2015, 8 : 31 - 36
  • [50] Acute limb ischemia after minimally invasive cardiac surgery using the ProGlide: A case series
    Jonggeun Lee
    Up Huh
    Seunghwan Song
    Chung Won Lee
    World Journal of Clinical Cases, 2022, (35) : 13052 - 13057