Does thoracic bioimpedance accurately determine cardiac output in COPD patients during maximal or intermittent exercise?

被引:48
|
作者
Bougault, V [1 ]
Lonsdorfer-Wolf, E [1 ]
Charloux, A [1 ]
Richard, R [1 ]
Geny, B [1 ]
Oswald-Mammosser, M [1 ]
机构
[1] Univ Hosp Strasbourg, Dept Resp Cardiocirculatory & Exercise Physiol, Strasbourg, France
关键词
cardiac output; COPD; exercise; Fick principle; impedance cardiography;
D O I
10.1378/chest.127.4.1122
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objectives: The monitoring of cardiac output (CO) during exercise rehabilitation in patients with COPD, often including strenuous exercise, is advisable. Invasive methods (thermodilution, Fick method) are accurate, but for clinical routine use noninvasive CO estimation is required. We have shown that impedance cardiography (Physio Flow; Manatee Biomedical; Macheren, France) is reliable in COPD patients at rest and during a recumbent, light-intensity exercise. The aim of our study was to evaluate the validity of this noninvasive device in COPD patients during a maximal incremental exercise test (IET) and also during a strenuous intermittent work exercise test (IWET). Design: Prospective comparative study of the impedance cardiograph vs the direct Fick method applied to oxygen. Patients: Eight patients with moderate-to-severe COPD (59 +/- 6 years old; FEV1, 38 +/- 15% predicted; residual volume, 194 +/- 64% predicted) [mean +/- SD]. Measurements and main results: Forty-nine simultaneous measurements of CO by means of the direct Fick method (COFICK) and CO measured by the impedance cardiograph (COPF) were obtained during the IET, and 108 measurements were made during the IWET. The correlation coefficients between the two measurements were r = 0.85 and r = 0.71 for the IET and the IWET, respectively. COPF was higher than COFICK. The difference between the two methods was 3.2 +/- 2.9 L/min during the IET and 2.5 +/- 2.1 L/min during the IWET. Expressed as a percentage of the mean of the two measurements, this corresponded to 31 +/- 21% and 25 +/- 20%, respectively. Conclusions: The relatively high number of values differing by > 20% precludes the use of impedance cardiography in clinical routine in such a difficult setting (hyperinflated patients and intense exercise).
引用
收藏
页码:1122 / 1131
页数:10
相关论文
共 50 条
  • [31] Cardiac output measurement during exercise in COPD: A comparison of dye dilution and impedance cardiography
    Louvaris, Zafeiris
    Spetsioti, Stavroula
    Andrianopoulos, Vasileios
    Chynkiamis, Nikolaos
    Habazettl, Helmut
    Wagner, Harrieth
    Zakynthinos, Spyros
    Wagner, Peter D.
    Vogiatzis, Ioannis
    CLINICAL RESPIRATORY JOURNAL, 2019, 13 (04): : 222 - 231
  • [32] Prolonged recovery of cardiac output after maximal exercise in patients with chronic heart failure
    Tanabe, Y
    Takahashi, M
    Hosaka, Y
    Ito, M
    Ito, E
    Suzuki, K
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (05) : 1228 - 1236
  • [33] ABNORMAL RESPONSE OF STROKE VOLUME AND CARDIAC OUTPUT DURING EXERCISE IN CARDIAC PATIENTS
    Fukuda, Taira
    Matsumoto, Akihiro
    Kurano-Meguro, Miwa
    Takano, Haruhito
    Iida, Haruko
    Maegawa, Taketeru
    Komatsu, Yutaka
    Kawahara, Takashi
    Hirata, Yasunobu
    Nagai, Ryozo
    Nakajima, Toshiaki
    JOURNAL OF PHYSIOLOGICAL SCIENCES, 2009, 59 : 133 - 133
  • [34] Why does the exercise cardiac output fall during altitude residence and is it important?
    Reeves, JT
    HYPOXI: INTO THE NEXT MILLENNIUM, 1999, 474 : 335 - 350
  • [35] TRANS-THORACIC ELECTRICAL BIOIMPEDANCE VERSUS THERMODILUTION TECHNIQUE FOR CARDIAC-OUTPUT MEASUREMENT DURING MECHANICAL VENTILATION
    PREISER, JC
    DAPER, A
    PARQUIER, JN
    CONTEMPRE, B
    VINCENT, JL
    INTENSIVE CARE MEDICINE, 1989, 15 (04) : 221 - 223
  • [36] Does music affect fatigue perception during exercise in COPD patients?
    Reychler, Gregory
    Clerens, Caroline
    Fizaine, Stephane
    Wasterlain, Emmanuelle
    Coppens, Thibault
    Maelle, Boland
    Pieters, Thierry
    Caty, Gilles
    Liistro, Giuseppe
    EUROPEAN RESPIRATORY JOURNAL, 2012, 40
  • [37] Does dynamic hyperinflation contribute to dyspnoea during exercise in patients with COPD?
    Guenette, Jordan A.
    Webb, Katherine A.
    O'Donnell, Denis E.
    EUROPEAN RESPIRATORY JOURNAL, 2012, 40 (02) : 322 - 329
  • [38] Influence of creatine supplementation on power output during intermittent maximal exercise:: a 31P-MRS study
    Yquel, RJ
    Arsac, LM
    Thiaudière, E
    Canioni, P
    Manier, G
    SCIENCE & SPORTS, 2002, 17 (03) : 143 - 145
  • [39] Comparison of thoracic electrical bioimpedance and thermodilution for the measurement of cardiac output in mechanically ventilated patients with chronic obstructive pulmonary disease
    Sifrer, F
    Drinovec, I
    9TH EUROPEAN CONGRESS ON INTENSIVE CARE MEDICINE, 1996, : 529 - 532
  • [40] Does HRV During Submaximal Exercise Transitions From Rest Relate To Maximal Cardiorespiratory Responses In COPD?
    Mazzuco, Adriana
    de Souza, Aline Soares
    Arbex, Flavio Ferlin
    Noman Alencar, Maria Clara
    Arena, Ross
    Phillips, Shane
    Borghi-Silva, Audrey
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (05): : 283 - 283