High resolution multidetector CT-aided tissue analysis and quantification of lung fibrosis

被引:102
|
作者
Zavaletta, Vanessa A.
Bartholmai, Brian J.
Robb, Richard A.
机构
[1] Mayo Clin Fdn, Rochester, MN 55905 USA
[2] Dept Radiol, Rochester, MN USA
[3] Dept Biophys, Rochester, MN USA
[4] Dept Comp Sci, Rochester, MN USA
[5] Mayo Clin Med, Rochester, MN USA
关键词
multidetector CT; lung imaging; tissue classification; quantitative lung analysis; texture analysis;
D O I
10.1016/j.acra.2007.03.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. Volumetric high-resolution scans can be acquired of the lungs with multidetector CT (MDCT). Such scans have potential to facilitate useful visualization, characterization, and quantification of the extent of diffuse lung diseases, such as usual interstitial pneumonitis or idiopathic pulmonary fibrosis (UIP/IPF). There is a need to objectify, standardize, and improve the accuracy and repeatability of pulmonary disease characterization and quantification from such scans. This article presents a novel texture analysis approach toward classification and quantification of various pathologies present in lungs with UIP/IPF. The approach integrates a texture matching method with histogram feature analysis. Materials and Methods. Patients with moderate UIP/IPF were scanned on a Lightspeed 8-detector GE CT scanner (140 kVp, 250 mAs). Images were reconstructed with 1.25-mm slice thickness in a high-frequency sparing algorithm (BONE) with 50% overlap and a 512 X 512 axial matrix, (0.625 mm(3) voxels). Eighteen scans were used in this study. Each dataset is preprocessed and includes segmentation of the lungs and the bronchovascular trees. Two types of analysis were performed, first an analysis of independent volume of interests (VOIs) and second an analysis of whole-lung datasets. 1) Fourteen of the 18 scans were used to create a database of independent 15 X 15 X 15 cubic voxel VOIs. The VOIs were selected by experts as having greater than 70% of the defined class. The database was composed of: honeycombing (number of VOIs 337), reticular (130), ground glass (148), normal (240), and emphysema (54). This database was used to develop our algorithm. Three progressively challenging classification experiments were designed to test our algorithm. All three experiments were performed using a 10-fold cross-validation method for error estimation. Experiment I consisted of a two-class discrimination: normal and abnormal. Experiment 2 consisted of a four-class discrimination: normal, reticular, honeycombing, and emphysema. Experiment 3 consisted of a five-class discrimination: normal, ground glass, reticular, honeycombing, and emphysema. 2) The remaining four scans were used to further test the algorithm on new data in the context of a whole lung analysis. Each of the four datasets was manually segmented by three experts. These datasets included normal, reticular and honeycombing regions and did not include ground glass or emphysema. The accuracy of the classification algorithm was then compared with results from experts. Results. Independent VOIs: 1) two-class discrimination problem (sensitivity, specificity): normal versus abnormal (92.96%, 93.78%). 2) Four-class discrimination problem: normal (92%, 95%), reticular (86%, 87%), honeycombing (74%, 98%), and emphysema (93%, 98%). 3) Five-class discrimination problem: normal (92%, 95%), ground glass (75%, 89%), reticular (22%, 92%), honeycombing (74%, 91%), and emphysema (94%, 98%). Whole-lung datasets: 1) William's index shows that algorithm classification of lungs agrees with the experts as well as the experts agree with themselves. 2) Student t-test between overlap measures of algorithm and expert (AE) and expert and expert (EE): normal (t = -1.20, P = .230), Reticular (t = -1.44, P =.155), Honeycombing (t = -3.15, P = .003). 3) Lung volumes intraclass correlation: dataset 1 (ICC = 0.9984, F = 0.0007); dataset 2 (ICC = 0.9559, F = 0); dataset 3 (ICC = 0.8623, F = 0.0015); dataset 4 (ICC = 0.7807, F = 0.0136). Conclusions. We have demonstrated that our novel method is computationally efficient and produces results comparable to expert radiologic judgment. It is effective in the classification of normal versus abnormal tissue and performs as well as the experts in distinguishing among typical pathologies present in lungs with UIP/IPF. The continuing development of quantitative metrics will improve quantification of disease and provide objective measures of disease progression.
引用
收藏
页码:772 / 787
页数:16
相关论文
共 50 条
  • [41] High-resolution CT of the lung II - Preface
    Lynch, DA
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2002, 40 (01) : XI - XI
  • [42] A CCD-based high resolution CT system for analysis of trabecular bone tissue
    Pasini, A
    Baruffaldi, F
    Bettuzzi, M
    Brancaccio, R
    Casali, F
    Cornacchia, S
    Lanconelli, N
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2273 - 2277
  • [43] Comparison between conventional interrupted high-resolution CT and volume multidetector CT acquisition in the assessment of bronchiectasis
    Hill, L. E.
    Ritchie, G.
    Wightman, A. J.
    Hill, A. T.
    Murchison, J. T.
    BRITISH JOURNAL OF RADIOLOGY, 2010, 83 (985): : 67 - 70
  • [44] Quantitative computer-aided analysis of diffuse lung disease in high-resolution computed tomography
    Uchiyama, Y
    Abe, H
    Li, F
    Shiraishi, J
    Li, Q
    Doi, K
    RADIOLOGY, 2002, 225 : 547 - 547
  • [45] Bioradiomic SPECT-CT quantification of active lung inflammation is influenced by heterogeneity of lung tissue
    Welham, Benjamin
    Bennett, Michael
    Ostridge, Kristoffer
    Guy, Matthew
    Zvavamwe, Clint
    Sundram, Francis
    Wilkinson, Tom
    EUROPEAN RESPIRATORY JOURNAL, 2023, 62
  • [46] Evaluation of a computer aided detection system for lung nodules with ground glass opacity component on multidetector-row CT
    Beigelman-Aubry, C.
    Hill, C.
    Boulanger, X.
    Brun, A. L.
    Leclercq, D.
    Golmard, J. L.
    Grenier, P. A.
    Lucidarme, O.
    JOURNAL DE RADIOLOGIE, 2009, 90 (12): : 1843 - 1849
  • [47] High-resolution CT quantification of bronchiectasis: Clinical and functional correlation
    Ooi, GC
    Khong, PL
    Chan-Yeung, M
    Ho, JCM
    Chan, PKS
    Lee, JCK
    Lam, WK
    Tsang, KWT
    RADIOLOGY, 2002, 225 (03) : 663 - 672
  • [48] LUNG LOBAR SEGMENTATION USING TUBULAR TISSUE DENSITY FROM MULTIDETECTOR-ROW CT IMAGES
    Kobashi, Syoji
    Hata, Yutaka
    INTERNATIONAL JOURNAL OF INNOVATIVE COMPUTING INFORMATION AND CONTROL, 2010, 6 (3A): : 829 - 842
  • [49] Comparative analysis of collagen quantification in the bleomycin mouse model of lung fibrosis
    Pittelli, Maria Gloria
    Caruso, Paola
    Faietti, Maria Laura
    Pitozzi, Vanessa
    Pontis, Silvia
    Bonatti, Martina
    Pioselli, Barbara
    Frati, Caterina
    Madeddu, Denise
    Quaini, Federico
    Lagrasta, Costanza
    Civelli, Maurizio
    Catinella, Silvia
    Villetti, Gino
    Trevisani, Marcello
    EUROPEAN RESPIRATORY JOURNAL, 2020, 56
  • [50] Serial high resolution CT findings in nonspecific interstitial pneumonia/fibrosis
    Nishiyama, O
    Kondoh, Y
    Taniguchi, H
    Yamaki, K
    Suzuki, R
    Yokoi, T
    Takagi, K
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (01) : 41 - 46