Bone marrow edema around the hip in non-traumatic pain: dual-energy CT vs MRI

被引:22
|
作者
Foti, Giovanni [1 ]
Faccioli, Niccolo [2 ]
Silva, Ronaldo [3 ]
Oliboni, Eugenio [1 ]
Zorzi, Claudio [4 ]
Carbognin, Giovanni [1 ]
机构
[1] IRCCS Sacro Cuore Don Calabria Hosp, Dept Radiol, Via Don A Sempreboni 10, I-37024 Negrar, Italy
[2] Verona Univ Hosp, Dept Radiol, Verona, Italy
[3] IRCCS Sacro Cuore Don Calabria Hosp, Clin Res Unit, Negrar, Italy
[4] IRCCS Sacro Cuore Don Calabria Hosp, Dept Orthoped Surg, Negrar, Italy
关键词
Hip joint; Magnetic resonance imaging; Multidetector computed tomography; Bone marrow; FEMORAL-HEAD; TRANSIENT OSTEOPOROSIS; CORE DECOMPRESSION; OSTEONECROSIS; RELIABILITY; FRACTURES; NECROSIS; LESIONS; UPDATE;
D O I
10.1007/s00330-020-06775-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) in identifying bone marrow edema (BME) around the hip joint in non-traumatic patients. Methods This prospective IRB-approved study was conducted between January 2019 and October 2019 and included 59 consecutive patients (18 males, 41 females; mean age 61.5 years, range 32-82) who were assessed by DECT and magnetic resonance imaging (MRI) within a 5-day period. Diagnostic accuracy values for diagnosing BME on a per-patient and on a per-partition-basis analysis were calculated for DECT images by two readers (R1 and R2, with 15 and 10 years of experience, respectively), using MRI as reference for diagnosis. Inter-observer agreements were calculated withk-statistics. Apvalue of < 0.05 was considered as statistically significant. Results MRI depicted BME in 44/59 patients (74.58%), with the involvement of 83/708 (11.72%) partitions. The sensitivity, specificity, and accuracy of R1 and R2 were 95.45% (42/44), 86.67% (13/15), and 93.22% (55/59) for R1, and 86.36% (38/44), 80.00% (12/15), and 84.75% (50/59) for R2. For both readers, the BME detection rate was higher in patients with severe edema (100%) in comparison to patients with mild edema (91.30% and 73.91%). In the partition-basis analysis, sensitivity, specificity, and accuracy ranges were 33.3 to 100%, 91.84 to 100%, and 88.14 to 100%, respectively. The inter-observer agreement for patients' analysis was substantial (k = 0.7065), whereas for partition analysis ranged from fair (k = 0.2976) to near-perfect (k = 1.000). Conclusion DECT can accurately identify BME around the hip joint, in comparison to MRI.
引用
收藏
页码:4098 / 4106
页数:9
相关论文
共 50 条
  • [31] Clinical Utility of Dual-Energy CT Analysis of Bone Marrow Edema in Acute Wrist Fractures
    Ali, Ismail T.
    Wong, William D.
    Liang, Teresa
    Khosa, Faisal
    Mian, Memoona
    Jalal, Sabeena
    Nicolaou, Savvas
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (04) : 842 - 847
  • [32] Detection of Bone Marrow Edema in the Head and Neck With Dual-Energy CT: Ready for Clinical Use?
    Timmer, Veronique C. M. L.
    van Kroonenburgh, Annemarieke M. J. L.
    Henneman, Wouter J. P.
    Vaassen, Lauretta A. A.
    Roele, Elise D.
    Kessler, Peter A. W. H.
    Postma, Alida A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 214 (04) : 893 - 899
  • [33] Dual-energy CT in vertebral compression fractures: performance of visual and quantitative analysis for bone marrow edema demonstration with comparison to MRI
    Guillaume Bierry
    Aïna Venkatasamy
    Stéphane Kremer
    Jean-Claude Dosch
    Jean-Louis Dietemann
    Skeletal Radiology, 2014, 43 : 485 - 492
  • [34] Dual-energy CT in vertebral compression fractures: performance of visual and quantitative analysis for bone marrow edema demonstration with comparison to MRI
    Bierry, Guillaume
    Venkatasamy, Aina
    Kremer, Stephane
    Dosch, Jean-Claude
    Dietemann, Jean-Louis
    SKELETAL RADIOLOGY, 2014, 43 (04) : 485 - 492
  • [35] Traumatic bone marrow lesions in dual-energy computed tomography
    Ren, Qiuping
    Tang, Deqiu
    Xiong, Zhiyuan
    Zhao, Heng
    Zhang, Shuixing
    INSIGHTS INTO IMAGING, 2022, 13 (01)
  • [36] Traumatic bone marrow lesions in dual-energy computed tomography
    Qiuping Ren
    Deqiu Tang
    Zhiyuan Xiong
    Heng Zhao
    Shuixing Zhang
    Insights into Imaging, 13
  • [37] Nondisplaced fractures on hip CT: added value of dual-energy CT virtual non-calcium imaging for detection of bone marrow edema using visual and quantitative analyses
    Jang, Seong Won
    Chung, Bo Mi
    Kim, Wan Tae
    Gil, Jea Ryung
    ACTA RADIOLOGICA, 2019, 60 (11) : 1465 - 1473
  • [38] Axial Spondyloarthritis: Dual-Energy Virtual Noncalcium CT in the Detection of Bone Marrow Edema in the Sacroiliac Joints
    Wu, Haijun
    Zhang, Guangfeng
    Shi, Lei
    Li, Xiuhui
    Chen, Min
    Huang, Xiaoyu
    Cao, Ximing
    Tan, Shaoheng
    Cui, Yang
    Liang, Changhong
    RADIOLOGY, 2019, 290 (01) : 157 - 164
  • [39] The Role of a Virtual Noncalcium Dual-Energy CT Application in the Detection of Bone Marrow Edema in Peripheral Osteomyelitis
    Yan, Yet Yen
    Ouellette, Hugue A.
    Saththianathan, Mayuran
    Munk, Peter L.
    Mallinson, Paul I.
    Sheikh, Adnan
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2022, 73 (03): : 549 - 556
  • [40] Diagnostic accuracy of dual-energy CT and virtual non-calcium techniques to evaluate bone marrow edema in vertebral compression fractures
    Giovanni Foti
    Alberto Beltramello
    Matteo Catania
    Stefano Rigotti
    Gerardo Serra
    Giovanni Carbognin
    La radiologia medica, 2019, 124 : 487 - 494