Surgical Outcomes of a Second Ahmed Glaucoma Valve Implantation in Asian Eyes with Refractory Glaucoma

被引:9
|
作者
Ong, Sze Chuan [1 ]
Aquino, Maria Cecilia [2 ]
Chew, Paul [2 ]
Koh, Victor [1 ,2 ]
机构
[1] Natl Univ Singapore, Yong Loo Lin Sch Med, Singapore 117597, Singapore
[2] Natl Univ Singapore Hosp, Dept Ophthalmol, Singapore 119228, Singapore
关键词
SEQUENTIAL GLAUCOMA; CLINICAL-EXPERIENCE; TRABECULECTOMY TVT; DRAINAGE DEVICE; TUBE; SILICONE; POLYPROPYLENE; SURGERY; CYCLOPHOTOCOAGULATION; COMPLICATIONS;
D O I
10.1155/2020/8741301
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Introduction. When the initial glaucoma tube shunt fails in eyes with refractory glaucoma, one option is implantation of an additional Ahmed glaucoma valve (AGV) to control intraocular pressure (IOP). We aim to evaluate the outcomes of a second AGV in Asian glaucoma. Material and Methods. This is a retrospective interventional study, consisting of 21 eyes belonging to 20 patients which underwent a second FP7 AGV. Data collected included demographic characteristics, best corrected visual acuity, IOP, and number of medications. Both intraoperative and postoperative complications or interventions were recorded. The primary outcome measurement was success rate: complete success (IOP >= 5 mmHg and <= 21 mmHg without IOP-lowering medications) and qualified success (IOP >= 5 mmHg and <= 21 mmHg with IOP-lowering medications). Failure was defined as IOP >= 5 mmHg and <= 21 mmHg, reoperations for IOP-related indications, removal of second AGV implant, or loss of light perception. Postoperative complications were included as secondary outcomes. Results. The cumulative failure rates were 9.5%, 20.0%, 32.5%, and 46.0% at six months, one year, two years, and three years of follow-up. At final follow-up, complete success and qualified success rates were 23.8% and 33.3%, respectively; mean IOP and number of medications decreased by 5.6 mmHg (23.9%) and 1.7 mmHg (54.8%), respectively, from preoperative baseline (P<0.01). More common postoperative complications included hypertensive phase (38.1%), corneal decompensation (23.8%), and tube exposure (14.3%). Conclusion. An additional AGV implant had good short and modest long-term effectiveness in reducing IOP following a failed glaucoma tube shunt in Asian eyes, with the mentioned common postoperative complications to be actively monitored and managed.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] A prospective comparative study on neovascular glaucoma and nonneovascular refractory glaucoma following Ahmed glaucoma valve implantation
    Li Zheng
    Zhou Minwen
    Wang Wei
    Huang Wenbin
    Chen Shida
    Li Xingyi
    Gao Xinbo
    Zhang Xiulan
    中华医学杂志(英文版), 2014, (08) : 1417 - 1422
  • [42] Efficacy of Ahmed Glaucoma Valve Implantation on Neovascular Glaucoma
    Xie, Zhan
    Liu, Hai
    Du, Mulong
    Zhu, Min
    Tighe, Sean
    Chen, Xue
    Yuan, Zhilan
    Sun, Hong
    INTERNATIONAL JOURNAL OF MEDICAL SCIENCES, 2019, 16 (10): : 1371 - 1376
  • [43] Long-term clinical outcomes of Ahmed valve implantation in patients with refractory glaucoma
    Lee, Chang Kyu
    Ma, Kyoung Tak
    Hong, Young Jae
    Kim, Chan Yun
    PLOS ONE, 2017, 12 (11):
  • [44] Ahmed Glaucoma Valve in Refractory Glaucoma: A Retrospective Study
    Kumar, Suresh
    Thakur, Sahil
    Sharma, Madhu
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2018, 12 (04) : NC8 - NC11
  • [45] Management of uveitic glaucoma with Ahmed glaucoma valve implantation
    Da Mata, A
    Burk, SE
    Netland, PA
    Baltatzis, S
    Christen, W
    Foster, CS
    OPHTHALMOLOGY, 1999, 106 (11) : 2168 - 2172
  • [46] Safety and Efficacy of Second Ahmed Valve Implant in Refractory Glaucoma
    Posarelli, Chiara
    Toro, Mario Damiano
    Rejdak, Robert
    Zarnowski, Tomasz
    Pozarowska, Dorota
    Longo, Antonio
    Miccoli, Mario
    Nardi, Marco
    Figus, Michele
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (07) : 1 - 12
  • [47] Evaluation of success after second Ahmed glaucoma valve implantation
    Nilforushan, Naveed
    Yadgari, Maryam
    Jazayeri, Anis Alsadat
    Karimi, Nasser
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2016, 64 (03) : 206 - 210
  • [48] The efficacy of Ahmed glaucoma valve drainage devices in cases of adult refractory glaucoma in Indian eyes
    Parihar, Jitendra K. S.
    Vats, Devendra P.
    Maggon, Rakesh
    Mathur, Vijay
    Singh, Anirudh
    Mishra, Sanjay K.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2009, 57 (05) : 345 - 350
  • [49] Ahmed glaucoma valve implantation with Ologen® Collagen Matrix for the surgical treatment of feline glaucoma
    Park, Kang-hyo
    Kim, Joon-Young
    Choo, Seoung-woo
    Yoon, Hun-young
    Jeong, Soon-wuk
    VETERINARY OPHTHALMOLOGY, 2018, 21 (01) : 96 - 100
  • [50] Trabeculectomy With Mitomycin C or Ahmed Valve Implantation in Eyes With Uveitic Glaucoma
    Bettis, Daniel I.
    Morshedi, Richard G.
    Chaya, Craig
    Goldsmith, Jason
    Crandall, Alan
    Zabriskie, Norm
    JOURNAL OF GLAUCOMA, 2015, 24 (08) : 591 - 599