On velocity estimation using speckle decorrelation

被引:0
|
作者
Li, PC [1 ]
Cheng, CJ [1 ]
Yeh, CK [1 ]
机构
[1] Natl Taiwan Univ, Dept Elect Engn, Taipei, Taiwan
关键词
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Quantitative estimation of blood velocity using Doppler techniques is fundamentally limited because only the axial component can be detected. Speckle decorrelation resulting from scatterer motion may be used to compute non-axial components and to obtain quantitative flow information. Based on both simulations and experimental results, it is shown that the decorrelation technique is feasible only for constant flows. If flow gradients are present, the correlation between two signals along the same line of observation may be significantly affected by the gradients. Therefore, the decorrelation method cannot be used for quantitative flow estimation if flow gradients are not accurately measured and effects on signal correlation are not fully compensated. Results in this paper show that accurate estimation of flow gradients is practically difficult. It is further shown that effects of signal-to-noise ratio (SNR) on the correlation must also be taken into account for quantitative flow analysis.
引用
收藏
页码:1084 / 1091
页数:8
相关论文
共 50 条
  • [41] Speckle Decorrelation of Motion in Ultrasound Fourier Images
    Zhang, Miaomiao
    Liebgott, Herve
    Varray, Francois
    Friboulet, Denis
    Bernard, Olivier
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 1203 - 1206
  • [42] Two-Dimensional Blood Flow Velocity Estimation Using Apparent Speckle Pattern Angle Dependence on Scan Velocity
    Xu, Tiantian
    Bashford, Gregory R.
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 319 - 322
  • [43] Estimation of a Dense Velocity Field Based on the Statistics of Dynamic Speckle
    Aoudi, Walid
    Vray, Didier
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2010, 20 (03) : 268 - 276
  • [44] Quantitative transverse flow measurement using optical coherence tomography speckle decorrelation analysis
    Liu, Xuan
    Huang, Yong
    Ramella-Roman, Jessica C.
    Mathews, Scott A.
    Kang, Jin U.
    OPTICS LETTERS, 2013, 38 (05) : 805 - 807
  • [45] MEASUREMENT OF ANGULAR VELOCITY USING SPECKLE PHOTOGRAPHY
    NARAYANAMURTHY, CS
    APPLIED OPTICS, 1991, 30 (22): : 3197 - 3199
  • [46] VELOCITY-MEASUREMENTS USING SPECKLE PATTERNS
    OHTSUBO, J
    KOHNO, T
    JOURNAL OF MECHANICAL ENGINEERING LABORATORY, 1980, 34 (04): : 194 - 207
  • [47] 3-D US frame positioning using speckle decorrelation and image registration
    Chang, RF
    Wu, WJ
    Chen, DR
    Chen, WM
    Shu, W
    Lee, JH
    Jeng, LB
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (06): : 801 - 812
  • [48] Probabilistic speckle decorrelation for 3D ultrasound
    Laporte, Catherine
    Arbel, Tal
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2007, PT 1, PROCEEDINGS, 2007, 4791 : 925 - +
  • [49] Speckle decorrelation in surface profilometry by wavelength scanning interferometry
    Inst of Physical and Chemical, Research, Saitama, Japan
    Appl Opt, 28 (6721-6728):
  • [50] Wavelength decorrelation of speckle in propagation through a thick diffuser
    Chang, Nien-An
    George, Nicholas
    Chi, Wanli
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2011, 28 (02) : 245 - 254