Purpose. An examination of studies that have assessed corneal biomechanical performance using the Ocular Response Analyzer (ORA: Reichert Ophthalmic Instruments, Depew, NY) raises some questions regarding the influence of measurement variables and the interpretation of the findings obtained with this instrument. This analysis of those questions describes additional factors which do or may contribute to the assessment of corneal hysteresis (CH). Methods. Using key words CH and ORA, English language articles relevant to this analysis were selected after a PubMed search with the addition of some articles referenced in the selected publications. Results. Corneal thickness, the level of edema, intraocular pressure, and corneal temperature as well as the area, location, rate, duration, and sequence of corneal unloading and loading may need to be considered as significant variables when assessing CH. Conclusions. CH values may be specific to measurement method and conditions rather than representing an unequivocal corneal property. Consideration of the uncontrolled variables involved may help explain some of the findings obtained with the ORA. That a CH measurement might vary with the sequence of unloading and loading suggests that the ORA CH finding may not represent the CH, but instead represents a hysteresis value better described as central, applanation-derived hysteresis, which is based on a very short unloading/loading sequence. The potential for the ORA to contribute to improved clinical management appears to be considerable but so does the need for better understanding and further development of its functions and applications. (Optom Vis Sci 2012;89:E343-E349)
引用
收藏
页码:E343 / E349
页数:7
相关论文
共 50 条
  • [1] Corneal hysteresis and corneal resistance factor in keratoectasia: Findings using the Reichert Ocular Response Analyzer
    Kirwan, Caitriona
    O'Malley, Donal
    O'Keefe, Michael
    [J]. OPHTHALMOLOGICA, 2008, 222 (05) : 334 - 337
  • [2] Corneal hysteresis and intraocular pressure measurement in children using the Reichert Ocular Response Analyzer
    Kirwan, Caitriona
    O'Keefe, Michael
    Lanigan, Bernadette
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 142 (06) : 990 - 992
  • [3] Corneal hysteresis measured with the Ocular Response Analyzer® in normal and glaucomatous eyes
    Abitbol, Olivia
    Bouden, Jihene
    Doan, Serge
    Hoang-Xuan, Thanh
    Gatinel, Damien
    [J]. ACTA OPHTHALMOLOGICA, 2010, 88 (01) : 116 - 119
  • [4] Corneal Hysteresis, Corneal Resistance Factor, and Intraocular Pressure Measurement in Patients with Scleroderma Using the Reichert Ocular Response Analyzer
    Emre, Sinan
    Kayikcioglu, Oezcan
    Ates, Halil
    Cinar, Esat
    Inceoglu, Nehir
    Yargucu, Figen
    Pirildar, Timur
    Oksel, Fahrettin
    [J]. CORNEA, 2010, 29 (06) : 628 - 631
  • [5] Measuring corneal hysteresis: threshold estimation of the waveform score from the Ocular Response Analyzer
    Marcelo Ayala
    Enping Chen
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2012, 250 : 1803 - 1806
  • [6] Measuring corneal hysteresis: threshold estimation of the waveform score from the Ocular Response Analyzer
    Ayala, Marcelo
    Chen, Enping
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 250 (12) : 1803 - 1806
  • [7] The Relationship Between Corvis ST Tonometry Parameters and Ocular Response Analyzer Corneal Hysteresis
    Fujishiro, Takashi
    Matsuura, Masato
    Fujino, Yuri
    Murata, Hiroshi
    Tokumo, Kana
    Nakakura, Shunsuke
    Kiuchi, Yoshiaki
    Asaoka, Ryo
    [J]. JOURNAL OF GLAUCOMA, 2020, 29 (06) : 479 - 484
  • [8] Assessment of corneal hysteresis measured by the ocular response analyzer as a screening tool in patients with glaucoma
    Schweitzer, Justin A.
    Ervin, Molly
    Berdahl, John P.
    [J]. CLINICAL OPHTHALMOLOGY, 2018, 12 : 1809 - 1813
  • [9] Contact lens effect on corneal hysteresis, IOP and EOP as measured by the Reichert ocular response analyzer
    Luce, D
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U576 - U576
  • [10] Effect of Aging on Corneal Biomechanical Parameters Using the Ocular Response Analyzer
    Kamiya, Kazutaka
    Shimizu, Kimiya
    Ohmoto, Fumiko
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (10) : 888 - 893